3.8. Pulse train input (RP)

The frequency command can be input from the pulse train input.
 Parameter
Title
fmod Frequency setting mode selection 1
f234 RP/high speed pulse input point 1 setting
f235 RP/high speed pulse input point 1 frequency
f236 RP/high speed pulse input point 2 setting
f237
RP/high speed pulse input point 2 frequency
f378
Number of RP terminal input pulses
f660 Override additional input selection
* Calculation of the reference frequency
The input pulse frequency is calculated to the percent base data. The calculated percent
data is converted to the frequency in accordance with 2 points setting (from f234 to
f237 ). Refer to the below figure.
Percent
Frequency
command
f237
f235
Function
=
base
data
Number
80Hz
0Hz
f234
0%
Percent base data and frequency command value
Adjustment range
1 - 12
11: RP pulse input
-100 - 100%
0.0 - fh Hz
0.0 - fh Hz
0 - 12
11: RP pulse input
Input
pulse
frequnecy
of
RP
terminal
input
pulses
Percent base data
f236
100%
15
Default setting
0 - 100%
1 - 9999
×
Maximum
frequency
Percent base data
E6581341
2
0
0.0
100
60.0
500
0
×