3. Functional description
In this section, functions added by the installation of this expansion IO card option, on top
of the standard inverter functions, are described.
Note: When power on or reset the inverter, the initialization of the ETB004Z terminal
3.1. Multi-function output terminal
Two output terminals and one relay output can be added. Function is similar to that of the
output terminals of the inverter, so refer to the inverter instruction manual.
Parameter
Title
f136 Output terminal function selection 7 (OUT5)
f137 Output terminal function selection 8 (OUT6)
f138 Output terminal function selection 9 (R2)
Monitor
Refer to the description on status monitor mode of inverter's instruction manual.
The output terminal status can be monitored by the output terminal status parameter
( fe07 ), and the parameter can be monitor by the serial communication.
fe07
bit No.
15 14 13 12 11 10
Symbol
---
---
Note: The OUT3, OUT4 and R1 are the terminal function of the expansion IO card option 1.
3.2. Multi-function input terminal
Four output terminals can be added. Function is similar to that of the input terminals of
the inverter, so refer to the inverter instruction manual.
Parameter
Title
f123 Input terminal selection 13 (LI5)
f124 Input terminal selection 14 (LI6)
f125 Input terminal selection 15 (LI5)
f126 Input terminal selection 16 (LI5)
f145 * Input terminal 13 - 20 response time selection
* This parameter for VF-PS1 exists for V654 or more.
inputs and outputs are delayed about 300ms from the inverter own terminals.
Function
9
---
---
---
---
---
Function
Adjustment range
0 - 255
0 - 255
0 - 255
8
7
6
5
R2 OUT6 OUT5 R1
Adjustment range
5 - 200ms
11
E6581341
Default setting
254 (Always OFF)
254 (Always OFF)
254 (Always OFF)
4
3
2
OUT4
OUT3
FL OUT2 OUT1
Default setting
0 - 155
0 - 155
0 - 155
0 - 155
1
0
0
0
0
0
8