  • Page 1 G363-ZR0-LAX1 HPC/AI Server - AMD EPYC™ 9004 - 3U DP HGX™ H100 4-GPU CPU and GPU Liquid cooling solution User Manual Rev. 1.0...
  • Page 2 For GIGABYTE distributors and resellers, additional sales & marketing materials are available from our reseller portal: http://reseller.b2b.gigabyte.com For further technical assistance, please contact your GIGABYTE representative or visit https://esupport.gigabyte.com/ to create a new support ticket For any general sales or marketing enquiries, you may also message GIGABYTE server directly by email: server.grp@gigabyte.com...
  • Page 3 Conventions The following conventions are used in this user's guide: NOTE! Pieces of additional information related to the current topic. CAUTION! Precautionary measures to avoid possible hardware or software problems. WARNING! Alerts to any damage that might result from doing or not doing specific actions.
  • Page 4 Server Warnings and Cautions Before installing a server, be sure that you understand the following warnings and cautions. WARNING! To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
  • Page 5 Electrostatic Discharge (ESD) CAUTION! ESD CAN DAMAGE DRIVES, BOARDS, AND OTHER PARTS. WE RECOMMEND THAT YOU PERFORM ALL PROCEDURES AT AN ESD WORKSTATION. IF ONE IS NOT AVAILABLE, PROVIDE SOME ESD PROTECTION BY WEARING AN ANTI-STATIC WRIST STRAP AT- TACHED TO CHASSIS GROUND -- ANY UNPAINTED METAL SURFACE -- ON YOUR SERVER WHEN HANDLING PARTS.
  • Page 6 Installing or removing jumpers: A jumper is a small plastic encased conductor that slips over two jumper pins. Some jumpers have a small tab on top that can be gripped with fin-gertips or with a pair of fine needle nosed pliers. If the jumpers do not have such a tab, take care when us- ing needle nosed pliers to remove or install a jumper;...
  • Page 7: Table Of Contents

    Table of Contents Chapter 1 Hardware Installation ................... 11 Installation Precautions .................. 11 Product Specifications ..................12 System Block Diagram ................... 16 Chapter 2 System Appearance ..................17 Front View ...................... 17 Rear View ....................... 18 Top View ......................18 Front Panel LEDs and Buttons ............... 19 RoT LEDs .......................
  • Page 8 Backplane Board Storage Connector ............. 54 4-4-1 CBP2081 (Front System Storage Board) ...............54 Chapter 5 BIOS Setup ....................55 The Main Menu ....................57 Advanced Menu ..................... 60 5-2-1 Trusted Computing ....................62 5-2-2 PSP Firmware Versions ..................63 5-2-3 Legacy Video Select ....................64 5-2-4 AST2600 Super IO Configuration ................65 5-2-5...
  • Page 9 5-4-2 CXL Range Encryption ..................158 Chipset Setup Menu ..................159 5-5-1 North Bridge ......................160 5-5-2 Fabric Resource ....................161 Server Management Menu ................163 5-6-1 System Event Log ....................165 5-6-2 View FRU Information ..................166 5-6-3 BMC Network Configuration .................167 5-6-4 IPv6 BMC Network Configuration .................168 Security Menu ....................
  • Page 10 This page intentionally left blank - 10 -...
  • Page 11: Chapter 1 Hardware Installation

    Chapter 1 Hardware Installation Installation Precautions The motherboard/system contain numerous delicate electronic circuits and components which can become damaged as a result of electrostatic discharge (ESD). Prior to installation, carefully read the service guide and follow these procedures: • Prior to installation, do not remove or break motherboard S/N (Serial Number) sticker or warranty sticker provided by your dealer.
  • Page 12: Product Specifications

    Product Specifications NOTE: We reserve the right to make any changes to the product specifications and product-related information without prior notice. System Security Server Socket Operating Properties Š 3U Dimension Š 448 (W) x 130 (H) x 800 (D) mm System fan Power Supply Š...
  • Page 13 Storage Front side: Š 4 x 2.5" Gen5 NVMe/SATA/SAS hot-swappable bays Š 4 x 2.5" Gen5 NVMe hot-swappable bays Š (4 x NVMe from CPU_0, 4 x NVMe from CPU_1, SATA from CPU_0) SAS card is required for SAS devices support Š...
  • Page 14 ocket Security Server Operating Properties System fan Power Supply Power Supply Š 2+1 3000W (240V) 80 PLUS Titanium redundant power supplies AC Input: Š 115-127V~/ 14.2A, 50-60Hz Š 200-220V~/ 15.8A, 50-60Hz Š 220-240V~/ 14.9A, 50-60Hz DC Input: Š 240Vdc/ 14A DC Output: Š...
  • Page 15 System Š Aspeed® AST2600 management controller Management Š GIGABYTE Management Console (AMI MegaRAC SP-X) web interface Š Dashboard Š HTML5 KVM Š Sensor Monitor (Voltage, RPM, Temperature, CPU Status …etc.) Š Sensor Reading History Data Š FRU Information Š SEL Log in Linear Storage / Circular Storage Policy Š...
  • Page 16: System Block Diagram

    System Block Diagram 10/100/1G MLAN (rear) switch 10/100/1G MLAN PHY(1ch) (front) ASPEED mini-DP AST2600 Intel I350-AM2 SATAIII x4 2 x 1G LAN NCSI NVMe x4 Switch NVMe x4 NCSI 4-bay 2.5” Gen5 NVMe/ SATA 2 x 10G (rear) 4-bay 2.5” Gen5 NVMe BASE-T LAN Broadcom PCIe3.0 x4...
  • Page 17: Chapter 2 System Appearance

    Chapter 2 System Appearance Front View SLOT6 SLOT5 Description PCIe Card Slot 10/100/1000 Server Management LAN Port* 1 GbE LAN Port x2 USB 3.2 Gen1 Port x 2 Mini DP Port PCIe Card Slot Front Panel LEDs and Buttons Note! 1.
  • Page 18: Rear View

    Rear View Coolant Coolant Supply Return Valve Valve PSU3 PSU2 PSU1 Description 10 GbE LAN Port x 2 10/100/1000 Server Management LAN Port* PCIe Card Slot Coolant Pipe Slot Note! Only one Management LAN (front side or rear) can be used at a time. •...
  • Page 19: Front Panel Leds And Buttons

    Front Panel LEDs and Buttons No. Name Color Status Description Reset Button Press this button to reset the system. Green Indicates the system is powered on. Power button with LED System is not powered on or in ACPI S5 state (power off) Indicates locating the HDD.
  • Page 20: Rot Leds

    RoT LEDs ID LED Status LED LED on Front panel (Note5) ID LED Status LED EC Firmware (FW) Authentication fail or not exit EC FW is broken or not exit (Note1) Authenticating/Recovering BMC/BIOS Images Authenticating Images Blinks Blue Blinks Green Recovering BMC Active Flash 4 times per second 4 times per second...
  • Page 21 Active Flash Authentication (AUTH) Fail Blinks Blue Blinks Green BMC : AUTH Fail (Note2) 1 time per second 1 time per second Blinks Blue Blinks Amber BIOS : AUTH fail (Note2) 1 time per second 1 time per second Blinks Blue Blinks Green 2 times per second 2 times per second...
  • Page 22: System Lan Leds

    System LAN LEDs Front System LAN LED Rear System LAN LED 4 3 4 Name Color Status Description Yellow 1 Gbps data rate 1GbE Speed Green 100 Mbps data rate 10 Mbps data rate Link between system and network or no access Green 1GbE Link / Blink...
  • Page 23: Power Supply Unit Led

    Power Supply Unit LED NOTE! The power supply may be vary based on the system configuration. PSU LED State Description No AC power to all power supplies 1Hz Green Blinking AC present / only standby on / Cold redundant mode 2Hz Green Blinking Power supply firmware updating mode AC cord unplugged or AC power lost;...
  • Page 24: Hard Disk Drive Leds

    Hard Disk Drive LEDs HDD Present RAID SKU Rebuilding LED1 Locate HDD Fault Access (No Access) Disk LED Green ON(*1) BLINK (*2) (LED on Back Panel) Amber No RAID configuration Green ON(*1) (via HBA) Removed HDD Slot (LED on Back Panel) Amber Green BLINK (*2)
  • Page 25: Chapter 3 System Hardware Installation

    Chapter 3 System Hardware Installation Pre-installation Instructions Computer components and electronic circuit boards can be damaged by discharges of static electricity. Working on computers that are still connected to a power supply can be extremely dangerous. Follow the simple guidelines below to avoid damage to your computer or injury to yourself.
  • Page 26: Removing And Installing The Top Cover

    Removing and Installing the Top Cover Before you remove the top cover: Make sure the system is not turned on or connected to AC power. Follow these instructions to remove the top cover: Unlock the plastic handle. Pull the grip handle. Remove the two screw securing the top cover.
  • Page 27: Removing And Installing The Hard Disk Drive

    Removing and Installing the Hard Disk Drive Read the following guidelines before you begin to install the hard disk drive: • Take note of the HDD tray orientation before sliding it out. • The tray will not fit back into the bay if it is inserted incorrectly. •...
  • Page 28: Liquid Cooling Assembly Information

    Liquid Cooling Assembly Information The liquid cooling assembly is designed to capture heat from the processors in the node and cool the components. The coolant flow for the assembly is produced by the four quick disconnects at the rear of the server chassis.
  • Page 29 The flow of the GPU baseboard coolant is shown below: Flow Order Component First Coolant into GPU Second GPU Cold Plate Third GPU Cold Plate Fourth To coolant return System Hardware Installation - 29 -...
  • Page 30: Liquid Cooling Specifications

    3-3-1 Liquid Cooling Specifications The cold plate assembly in the liquid cooling assembly mounts directly on top of the processors and GPUs. The retention mechanism for installation on top of the processors is integrated into the cold plate. The liquid coolant contained within the tubes, is a mixture of demineralized water and propylene glycol with the following beneficial features: Anti-Freeze, Anti-Corrosion and Anti Bacterial.
  • Page 31: Removing And Installing The Cpu

    Removing and Installing the CPU Read the following guidelines before you begin to install the CPU: • Make sure that the motherboard supports the CPU. • Always turn off the computer and unplug the power cord from the power outlet before installing the CPU to prevent hardware damage.
  • Page 32 • Lock the CPU by using a Torx T20 screwdriver to tighten screw. • The screw tightening torque: 12.5-15.0 kgf-cm. System Hardware Installation - 32 -...
  • Page 33: Removing And Installing Memory

    Removing and Installing Memory Read the following guidelines before you begin to install the memory: • Make sure that the motherboard supports the memory. It is recommended that memory of the same capacity, brand, speed, and chips be used. • Always turn off the computer and unplug the power cord from the power outlet before installing the memory to prevent hardware damage.
  • Page 34: Removing And Installing A Memory Module

    3-5-2 Removing and Installing a Memory Module Before installing a memory module, make sure to turn off the computer and unplug the power cord from the power outlet to prevent damage to the memory module. Be sure to install DDR5 DIMMs on to this motherboard.
  • Page 35: Memory Population Table

    3-5-4 Memory Population Table EPYC Memory Speed based on DIMM Population (One DIMM per Channel) DIMM Population DIMM Max EPYC 9004 Type DDR5 Frequency (MT/s) DIMM 0 1R (1 Rank) 4800 RDIMM 2R (2 Ranks) 4800 2S2R (4 Ranks) 4800 3DS RDIMM 2S4R (8 Ranks) 4800...
  • Page 36: Removing And Installing The Pcie Card

    Removing and Installing the PCIe Card • Voltages can be present within the server whenever an AC power source is connected. This voltage is present even when the main power switch is in the off position. Ensure that the system is powered off and all power sources have been disconnected from the server prior to installing a PCIe card.
  • Page 37: Installing And Removing An M.2 Solid State Drive

    Installing and Removing an M.2 Solid State Drive Follow these instructions to install an optional M.2 solid state drive (SSD): NOTE: To install/remove the M.2 solid state drive use a No. 1 Phillips-head screwdriver with a screw torque of 1.5 ± 0.2 kgf*cm Place the solid state drive into the M.2 module.
  • Page 38: Removing And Installing The Backup Battery Unit

    Removing and Installing the Backup Battery Unit Follow these instructions to replace the backup battery unit: Remove the two screws securing the battery unit enclosure. Remove the battery unit enclosure. Remove the battery unit enclosure metal cover. Insert the replacement batteries firmly into the enclosure. Replace the metal cover and lock it with screw.
  • Page 39: Removing And Installing The Power Supply

    Removing and Installing the Power Supply Follow these instructions to replace the power supply: Flip up and then grasp the power supply handle. Press the retaining clip on the right side of the power supply unit in the direction indicated. Pull out the power supply unit using the handle.
  • Page 40: Cable Routing

    3-10 Cable Routing CPU0 CPU1 Motherboard: FBTN_IO Front Panel LEDs and Buttons Cable Front IO Board: FP_1 CPU0 CPU1 OCP Card: -- OCP NCSI Signal Cable PCIe Baseboard: U2_NCSI1 System Hardware Installation - 40 -...
  • Page 41 CPU0 CPU1 CPU0 CPU1 OCP Card: A1: MCIO_CD/ A2: MCIO_AB PCIe Baseboard: U2_PEX2 Motherboard: U2_P0_P1 CPU0 PCIe Baseboard: U2_PEX1 Baseboard PCIe Signal Cable Motherboard: U2_P1_PE3 PCIe Baseboard: U2_PEX4 Motherboard: U2_P1_PE0 PCIe Baseboard: U2_PEX3 System Hardware Installation - 41 -...
  • Page 42 CPU0 CPU1 PCIe Riser: -- System Front PCIe Signal Cable Motherboard: U2_P1_P2 CPU0 CPU1 PCIe Riser: -- System Front PCIe Power Cable PCIe Baseboard: PCIE_PWR1 System Hardware Installation - 42 -...
  • Page 43 CPU0 CPU1 Motherboard: ATX1 PCIe Baseboard: ATX1 System Power Cable Motherboard: ATX2 PCIe Baseboard: ATX1 CPU0 CPU1 Motherboard: REAR_IO Management LAN Signal Cable PCIe Baseboard: REDSTONE System Hardware Installation - 43 -...
  • Page 44 CPU0 CPU1 Motherboard: U2_P1_P0 Motherboard to PCIe Baseboard 8i to 4i Cable PCIe Baseboard: U2_1 CPU0 CPU1 Motherboard: PDB_IO Power On Signal Cable PCIe Baseboard: PDB_IO System Hardware Installation - 44 -...
  • Page 45 CPU0 CPU1 Motherboard : SATA0 SATA Cable F/ HDD Board: SL_SAS0 System Hardware Installation - 45 -...
  • Page 46 CPU0 CPU1 F/ HDD Board: F/ HDD Board: A1: U_2_0 C1: U_2_4 NVMe 0-1 NVMe 4-5 A2: U_2_1 C2: U_2_5 Cable Cable PCIe Baseboard: PCIe Baseboard: MCIO2_1 MCIO3_1 F/ HDD Board: F/ HDD Board: B1: U_2_2 D1: U_2_6 NVMe 2-3 NVMe 6-7 B2: U_2_3 D2: U_2_7...
  • Page 47 CPU0 CPU1 Motherboard: BP_1 PCIe Baseboard: BP_1 HDD Backplane Board Signal Cable F/ HDD Board: BP_1 PCIe Baseboard: BP_SERIES1 CPU0 CPU1 PCIe Baseboard: HDD_PWR2 HDD Backplane Board Power Cable F/ HDD Board: ATX1 System Hardware Installation - 47 -...
  • Page 48 CPU0 CPU1 Fan Board Signal Cable PCIe Baseboard: SMB_CON2 CPU0 CPU1 PDB Signal Cable PCIe Baseboard: SMB_CON1 System Hardware Installation - 48 -...
  • Page 49: Motherboard Components

    Chapter 4 Motherboard Components Motherboard Components DIMM_P0_L0 DIMM_P1_R0 DIMM_P0_K0 DIMM_P1_Q0 DIMM_P0_J0 DIMM_P1_P0 DIMM_P0_I0 DIMM_P1_O0 DIMM_P0_H0 DIMM_P1_N0 DIMM_P0_G0 DIMM_P1_M0 CPU0 CPU1 DIMM_P0_A0 DIMM_P1_S0 DIMM_P0_B0 DIMM_P1_T0 DIMM_P0_C0 DIMM_P1_U0 DIMM_P0_D0 DIMM_P1_V0 DIMM_P0_E0 DIMM_P1_W0 DIMM_P0_F0 DIMM_P1_X0 9 10 Item Description OCP 3.0 Connector (PCIe Gen5 x16) Proprietary PCIe Slot (Gen 5/x16 slot/GENZ_2) Serial Port Cable Connector IPMB Connector...
  • Page 50: Jumper Settings

    Jumper Settings NCSI Switch Clear CMOS 1 2 3 Front Side MLAN CLR_CMOS Rear Side MLAN Default Enable CPU0 CPU1 HSMB_SEL BIOS defined Reserved BIOS_PWD Clear supervisor password Normal [Default] BIOS_RCVR BIOS recovery mode Normal [Default] Motherboard Components - 52 -...
  • Page 51: Io Board

    IO Board 4-3-1 CLBH160 CPU0 CPU1 IO Board Item Description 10/100/1000 Server Management LAN Port 1GbE LAN Port #2 1GbE LAN Port #1 USB 3.2 Gen1 Port x 2 Mini DP Port Motherboard Components - 53 -...
  • Page 52: Backplane Board Storage Connector

    Backplane Board Storage Connector 4-4-1 CBP2081 (Front System Storage Board) Item Description SlimLine SAS Connector (SFF-8654 4i/U.2_0) SlimLine SAS Connector (SFF-8654 4i/U.2_1) SlimLine SAS Connector (SFF-8654 4i/U.2_2) SlimLine SAS Connector (SFF-8654 4i/U.2_3) SlimLine SAS Connector (SFF-8654 4i/U.2_4) SlimLine SAS Connector (SFF-8654 4i/U.2_5) SlimLine SAS Connector (SFF-8654 4i/U.2_6) SlimLine SAS Connector (SFF-8654 4i/U.2_7) SlimLine SAS Connector (SFF-8654 4i/SL_SAS1)
  • Page 53: Chapter 5 Bios Setup

    Chapter 5 BIOS Setup BIOS (Basic Input and Output System) records hardware parameters of the system in the EFI on the motherboard. Its major functions include conducting the Power-On Self-Test (POST) during system startup, saving system parameters, loading the operating system etc. The BIOS includes a BIOS Setup program that allows the user to modify basic system configuration settings or to activate certain system features.
  • Page 54  Main This setup page includes all the items of the standard compatible BIOS.  Advanced This setup page includes all the items of AMI BIOS special enhanced features. (ex: Auto detect fan and temperature status, automatically configure hard disk parameters.) ...
  • Page 55: The Main Menu

    The Main Menu Once you enter the BIOS Setup program, the Main Menu (as shown below) appears on the screen. Use arrow keys to move among the items and press <Enter> to accept or enter other sub-menu. Main Menu Help The on-screen description of a highlighted setup option is displayed on the bottom line of the Main Menu.
  • Page 56 Parameter Description BIOS Information Project Name Displays the project name information. Project Version Displays version number of the BIOS setup utility. Build Date and Time Displays the date and time when the BIOS setup utility was created. BMC Information (Note1) BMC Firmware Version (Note1) Displays BMC firmware version information.
  • Page 57 Parameter Description Onboard LAN Information LAN1 MAC Address (Note) Displays LAN MAC address information. LAN2 MAC Address Displays LAN MAC address information. (Note) System Date Sets the date following the weekday-month-day-year format. System Time Sets the system time following the hour-minute-second format. (Note) The number of LAN ports listed will depend on the motherboard / system model.
  • Page 58: Advanced Menu

    Advanced Menu The Advanced Menu displays submenu options for configuring the function of various hardware components. Select a submenu item, then press <Enter> to access the related submenu screen. When Boot Mode Select is set to UEFI (Default) BIOS Setup - 60 -...
  • Page 59 When "Boot Mode Select" is set to Legacy in the Boot > Boot Mode Select section BIOS Setup - 61 -...
  • Page 60: Trusted Computing

    5-2-1 Trusted Computing Parameter Description Configuration Enable/Disable BIOS support for security device. OS will not show security device. TCG EFI protocol and INT1A interface will not be Security Device Support available. Options available: Disable, Enable. Default setting is Enable. Select Enable to activate TPM support feature. SPI TPM Support Options available: Disabled, Enabled.
  • Page 61 5-2-2 PSP Firmware Versions The PSP Firmware Versions page displays the basic PSP firmware version information. Items on this window are non-configurable. BIOS Setup - 63 -...
  • Page 62: Legacy Video Select

    5-2-3 Legacy Video Select Description Parameter Selects between onboard or external VGA support. OnBrd/Ext VGA Select Options available: Auto, Onboard, External. Default setting is Auto. This configurable option will be displayed when "Boot Mode Select" is set to Legacy in the Boot > (Note) Boot Mode Select section.
  • Page 63: Ast2600 Super Io Configuration

    5-2-4 AST2600 Super IO Configuration Description Parameter AST2600 Super IO Configuration Super IO Chip Displays the super IO chip information Serial Port 1 Press [Enter] for configuration of advanced items. Configuration BIOS Setup - 65 -...
  • Page 64 5-2-4-1 Serial Port 1 Configuration Description Parameter Serial Port 1 Configuration Enable/Disable the Serial Port (COM). When set to Enabled allows you to configure the Serial port 1 settings. When set to Disabled, displays no Serial Port (Note) configuration for the serial port. Options available: Disabled, Enabled.
  • Page 65: S5 Rtc Wake Settings

    5-2-5 S5 RTC Wake Settings Parameter Description Enable/Disable system wake on alarm event. Options available: Disabled, Fixed Time, Dynamic Time. When Fixed Time Wake System from S5 is selected, system will wake on the hr::min::sec specified. Default setting is Disabled. BIOS Setup - 67 -...
  • Page 66: Serial Port Console Redirection

    5-2-6 Serial Port Console Redirection Parameter Description Select whether to enable console redirection for specified device. Console COM1/Serial Over LAN redirection enables the users to manage the system from a remote Console Redirection (Note) location. Options available: Enabled, Disabled. Default setting is Disabled. Press [Enter] to configure advanced items.
  • Page 67 Parameter Description Parity Š – A parity bit can be sent with the data bits to detect some transmission errors. – Even: parity bit is 0 if the num of 1's in the data bits is even. – Odd: parity bit is 0 if num of 1's in the data bits is odd. –...
  • Page 68 Parameter Description Legacy Console Redirection Press [Enter] to configure advanced items. Redirection COM Port Š – Selects a COM port for Legacy serial redirection. – Default setting is COM1/SOL. Resolution Š – Selects the number of rows and columns used in Console Redirection for legacy OS support.
  • Page 69 Parameter Description Flow Control Š – Flow control can prevent data loss from buffer overflow. When sending data, if the receiving buffers are full, a 'stop' signal can Serial Port for Out-of-Band be sent to stop the data flow. Once the buffers are empty, a 'start' EMS Console Redirection signal can be sent to re-start the flow.
  • Page 70: Cpu Configuration

    5-2-7 CPU Configuration Description Parameter Enable/Disable the CPU Verbalization. SVM Mode Options available: Disabled, Enabled. Default setting is Enabled. Press [Enter] to view the memory information related to CPU 0/1. CPU 0/1 Information BIOS Setup - 72 -...
  • Page 71 5-2-8 PCI Subsystem Settings BIOS Setup - 73 -...
  • Page 72 Description Parameter Displays the PCI Bus Driver version information. PCI Bus Driver Version GENZ_#_Lanes Configuration (Note1) Change the PCIe lanes. U2_P0_P_#_Lanes Configuration (Note2) Options available: Disabled, Auto, x16, x8x8, x8x4x4, x4x4x8, U2_P1_P_#_Lanes Configuration (Note2) x4x4x4x4. Default setting is Auto. OCP Lanes Configuration GENZ_#_I/O ROM (Note1) When enabled, this setting will initialize the device expansion ROM...
  • Page 73: Usb Configuration

    5-2-9 USB Configuration Parameter Description USB Configuration USB Module Version Displays the USB module version information. USB Controllers Displays the supported USB controllers. USB Devices: Displays the USB devices connected to the system. Enable/Disable the Legacy USB support function. AUTO option disables legacy support if no USB devices are connected.
  • Page 74 Parameter Description Selects the time-out value during a USB mass storage device reset. Device reset time-out Options available: 10 sec, 20 sec, 30 sec, 40 sec. Default setting is 20 sec. Maximum time the device will take before it properly reports itself to the Host Controller.
  • Page 75: Network Stack Configuration

    5-2-10 Network Stack Configuration Parameter Description Enable/Disable the UEFI network stack. Network Stack Options available: Enabled, Disabled. Default setting is Enabled. Enable/Disable the Ipv4 PXE feature. Ipv4 PXE Support Options available: Enabled, Disabled. Default setting is Enabled. Enable/Disable the Ipv4 HTTP feature. Ipv4 HTTP Support Options available: Enabled, Disabled.
  • Page 76: Post Report Configuration

    5-2-11 Post Report Configuration Parameter Description Post Report Configuration Error Message Report Enable/Disable the POST Error Message support. Post Error Message Options available: Enabled, Disabled. Default setting is Enabled. Halt On Options available: No Error, All Error. Default setting is No Error. BIOS Setup - 78 -...
  • Page 77: Nvme Configuration

    5-2-12 NVMe Configuration Parameter Description NVMe Configuration Displays the NVMe devices connected to the system. Enable/Disable NVMe LED Control. NVMe LED Control Options available: System Default, Disabled, Enabled. Default setting is System Default. BIOS Setup - 79 -...
  • Page 78: Sata Configuration

    5-2-13 SATA Configuration Parameter Description Displays the installed HDD devices information. System will automatically SATA Configuration detect HDD type. BIOS Setup - 80 -...
  • Page 79: Graphic Output Configuration

    5-2-14 Graphic Output Configuration Parameter Description Selects output device type. Output Device Type Options available: First loaded Device, Onboard Device, External Device, Specific Device. Default setting is Onboard Device. BIOS Setup - 81 -...
  • Page 80: Amd Mem Configuration Status

    5-2-15 AMD Mem Configuration Status Description Parameter Press [Enter] to view the memory configuration status related to CPU 0/1. CPU 0/1 BIOS Setup - 82 -...
  • Page 81: Tls Auth Configuration

    5-2-16 Tls Auth Configuration Parameter Description Press [Enter] for configuration of advanced items. Enroll Cert Š – Press [Enter] to enroll a certificate • Enroll Cert Using File • Cert GUID Server CA Configuration Input digit character in 1111111-2222-3333-4444-1234567890ab format. –...
  • Page 82: Ram Disk Configuration

    5-2-17 RAM Disk Configuration Parameter Description Specifies the type of memory to use from available memory pool in system to create a disk. Disk Memory Type Options available: Boot Service Data, Reserved. Default setting is Boot Service Data. Creates a raw RAM disk. Size (Hex) Š...
  • Page 83: Iscsi Configuration

    5-2-18 iSCSI Configuration Parameter Description Press [Enter] and name iSCSI Initiator. Only IQN format is accepted. iSCSI Initiator Name Range: from 4 to 223 Add an Attempt Press [Enter] to configure advanced items. Delete Attempts Press [Enter] to configure advanced items. Change Attempt Order Press [Enter] to configure advanced items.
  • Page 84 5-2-19 Intel(R) I350 Gigabit Network Connection BIOS Setup - 86 -...
  • Page 85 Description Parameter Press [Enter] to configure advanced items. Link Speed Š – Allows for automatic link speed adjustment. – Options available: Auto Negotiated, 10 Mbps Half, 10 Mbps Full, 100 Mbps Half, 100 Mbps Full. Default setting is Auto Negotiated. Wake On LAN NIC Configuration Š...
  • Page 86: Vlan Configuration

    5-2-20 VLAN Configuration Parameter Description Press [Enter] to configure advanced items. Create new VLAN Š VLAN ID Š – Sets VLAN ID for a new VLAN or an existing VLAN. – Press the <+> / <-> keys to increase or decrease the desired values. –...
  • Page 87: Mac Ipv4 Network Configuration

    5-2-21 MAC IPv4 Network Configuration Parameter Description Indicates whether network address is configured successfully or not. Configured Options available: Enabled, Disabled. Default setting is Disabled. Options available: Enabled, Disabled. Default setting is Disabled. Enable DHCP (Note) Local IP Address Press [Enter] to configure local IP address. (Note) Press [Enter] to configure local NetMask.
  • Page 88: Mac Ipv6 Network Configuration

    5-2-22 MAC IPv6 Network Configuration Parameter Description Press [Enter] to configure advanced items. Displays the MAC Address information. Š Interface ID Š – The 64 bit alternative interface ID for the device. The string is colon separated. e.g. ff:dd:88:66:cc:1:2:3. DAD Transmit Count Š...
  • Page 89: Broadcom Bcm57416 10Gbase-T Network Connection

    5-2-23 Broadcom BCM57416 10GBASE-T Network Connection Parameter Description Press [Enter] to view firmware image information. Firmware Image Menu Press [Enter] to configure advanced items. Multi-Function Mode Š – Configures the NIC Hardware Mode. – Options available: SF, NPAR 1.0. Default setting is SF. SR-IOV Š...
  • Page 90 Description Parameter Support RDMA Š – Enable/Disable RDMA support for this port. – Options available: Disabled, Enabled. Default setting is Disabled. DCB Protocol Š – Enable/Disable DCB protocol. – Options available: Disabled, Enabled (IEEE only), CEE (only), Both (IEEE preferred with fallback to CEE). Default setting is Disabled. LLDP nearest bridge Š...
  • Page 91 Parameter Description Pre-boot Wake On LAN Š – Configures Pre-boot Wake on LAN (WOL). – Options available: Disabled, Enabled. Default setting is Enabled. VLAN Mode Š – Configures the virtual LAN (VLAN) mode. – Options available: Disabled, Enabled. Default setting is Disabled. MBA Configuration Menu VLAN ID Š...
  • Page 92: Vlan Configuration

    5-2-24 VLAN Configuration Parameter Description Press [Enter] to configure advanced items. Create new VLAN Š VLAN ID Š – Sets VLAN ID for a new VLAN or an existing VLAN. – Press the <+> / <-> keys to increase or decrease the desired values. –...
  • Page 93: Mac Ipv4 Network Configuration

    5-2-25 MAC IPv4 Network Configuration Parameter Description Indicates whether network address is configured successfully or not. Configured Options available: Enabled, Disabled. Default setting is Disabled. Options available: Enabled, Disabled. Default setting is Disabled. Enable DHCP (Note) Local IP Address Press [Enter] to configure local IP address. (Note) Press [Enter] to configure local NetMask.
  • Page 94: Mac Ipv6 Network Configuration

    5-2-26 MAC IPv6 Network Configuration Parameter Description Press [Enter] to configure advanced items. Displays the MAC Address information. Š Interface ID Š – The 64 bit alternative interface ID for the device. The string is colon separated. e.g. ff:dd:88:66:cc:1:2:3. DAD Transmit Count Š...
  • Page 95: Amd Cbs Menu

    AMD CBS Menu AMD CBS menu displays submenu options for configuring the CPU-related information that the BIOS automatically sets. Select a submenu item, then press [Enter] to access the related submenu screen. BIOS Setup - 97 -...
  • Page 96 5-3-1 CPU Common Options BIOS Setup - 98 -...
  • Page 97: Cpu Common Options

    Parameter Description CPU Common Options Performance Press [Enter] for configuration of advanced items. Allow REP-MOV/STOS to use non-caching streaming stores for large sizes. REP-MOV/STOS Streaming Options available: Disabled, Enabled. Default setting is Enabled. Prefetcher settings Press [Enter] for configuration of advanced items. Core Watchdog Press [Enter] for configuration of advanced items.
  • Page 98 Parameter Description Enabled: Enter system memory is covered. SNP Memory (RMP Table) Options available: Disabled, Enabled, Custom, Auto. Coverage Default setting is Auto. Controls the Secure Memory Encryption Enable (SMEE) function. SMEE Options available: Disable, Enable, Auto. Default setting is Auto. Action to take when a CCD BIST failure is detected.
  • Page 99 5-3-1-1 Performance Parameter Description Performance Options available: Normal Operation, Customized. Default setting is Normal OC Mode (Note) Operation. Allows you to accept or decline enabling Custom Core Pstates. When Custom Core Pstates accepted, you can disable or customize core pstates. Allows you to accept or decline enabling CCDs, processor cores and threads.
  • Page 100 5-3-1-2 Prefetcher Settings Parameter Description Prefetcher settings Enable/Disable L1 Stream HW Prefetcher. L1 Stream HW Prefetcher Options available: Disable, Enable, Auto. Default setting is Auto. Use memory access history of individual instructions to fetch additional lines when each access is a constant distance from the previous. L1 Stride Prefetcher Enable/Disable L1 Stride Prefetcher.
  • Page 101 5-3-1-3 Core Watchdog Parameter Description Core Watchdog Enable/Disable CPU Watchdog Timer. Core Watchdog Timer Enable (Note) Options available: Disabled, Enabled, Auto. Default setting is Auto. Select the CPU Watchdog Timer interval. Options available: 2.681s, 1.340s, 669.41ms, 334.05ms, 166.37ms, Core Watchdog Timer Interval 82.53ms, 40.61ms, 20.970ms, 10.484ms,5.241ms, 2.620ms, 1.309ms, 654.08us, 326.4us, 162.56us, 80.64us, 39.68us, Auto.
  • Page 102: Df Common Options

    5-3-2 DF Common Options Parameter Description DF Common Options Memory Addressing Press [Enter] for configuration of advanced items. ACPI Press [Enter] for configuration of advanced items. Link Press [Enter] for configuration of advanced items. SDCI Press [Enter] for configuration of advanced items. Probe Filter Press [Enter] for configuration of advanced items.
  • Page 103 5-3-2-1 Memory Addressing Parameter Description Memory Addressing Specifies the number of desired NUMA nodes per socket. Options available: NPS0,NPS1,NPS2,NPS4, Auto. Default setting is Auto. NUMA nodes per socket NOTE! • Available options may vary by system configuration. • Only dual processor configuration supports NPS0. Enable/Disable the Memory interleaving feature.
  • Page 104 5-3-2-2 ACPI Parameter Description ACPI ACPI SRAT L3 Cache As Enable/Disable report each L3 cache as a NUMA Domain to the OS. NUMA Domain Options available: Disabled, Enabled, Auto. Default setting is Auto. Determines how the SLIT distances are declared. ACPI SLIT Distance Control Options available: Manual, Auto.
  • Page 105 5-3-2-3 Link Parameter Description Enable/Disable GMI link encryption. GMI encryption control Options available: Disabled, Enabled, Auto. Default setting is Auto. Enable/Disable xGMI link encryption. xGMI encryption control Options available: Disabled, Enabled, Auto. Default setting is Auto. Configures the number of xGMI2 links used on a multi-socket system. xGMI Link Configuration Options available: Auto, 3 xGMI Links, 4 xGMI Links.
  • Page 106 Parameter Description xGMI Global Preset List Press [Enter] to configure the xGMI Preset list. xGMI Initial Preset Press [Enter] to configure the xGMI Initial Preset CPU0/1 link. xGMI TXEQ Search Mask Press [Enter] to configure the xGMI TXEQ Search Mask CPU0/1 link. Press [Enter] to configure the xGMI AC/DC Coupled link.
  • Page 107 5-3-2-4 SDCI Parameter Description Options available: Disabled, Enabled, Auto. Default setting is Auto. SDCI (Note) DisRmSteer Options available: Disabled, Enabled, Auto. Default setting is Auto. (Note) Advanced items prompt when this item is defined. BIOS Setup - 109 -...
  • Page 108 5-3-2-5 Probe Filter Parameter Description Specifies whether multiple memory/CXL channels will share probe filter storage. For memory sizes of 16TB or larger, this features is ignored as it is Organization auto-selected to 'shared'. Options available: Disabled, Shared, Auto. Default setting is Auto. Controls PDR settings that may impact performance by workload and/or processor.
  • Page 109: Umc Common Options

    5-3-3 UMC Common Options Parameter Description UMC Common Options DDR Addressing Options Press [Enter] for configuration of advanced items. DDR Controller Configuration Press [Enter] for configuration of advanced items. DDR MBIST Options Press [Enter] for configuration of advanced items. DDR RAS Press [Enter] for configuration of advanced items.
  • Page 110 5-3-3-1 DDR Addressing Options Parameter Description DDR Addressing Options Interleaves memory blocks across the DRAM chip selects for node 0. Chipselect Interleaving Options available: Disabled, Auto. Default setting is Auto. Enable or disable bank addressing hashing. Address Hash Bank Options available: Enabled, Disabled, Auto. Default setting is Auto. Enable or disable CS addressing hashing.
  • Page 111 5-3-3-2 DDR Controller Configuration Parameter Description DDR Cotroller Configuration DDR Power Options Press [Enter] for configuration of advanced items. Memory Channel Diable Press [Enter] for configuration of advanced items. Refresh Management (RFM) Press [Enter] for configuration of advanced items. BIOS Setup - 113 -...
  • Page 112 5-3-3-2-1 DDR Power Options Parameter Description DDR Power Options Enable or disable DDR power down mode. Power Down Enable Options available: Enabled, Disabled, Auto. Default setting is Auto. Sub Urgent Refresh Lower Specifies the stored refresh limit required to enter sub-urgent refresh mode. Bound Urgent Refresh Limit Specifies the stored refresh limit required to enter urgent refresh mode.
  • Page 113 5-3-3-2-2 Memory Channel Disable Parameter Description Memory Channel Disable Memory Channel Disable Bitmask CPU0/1 Channel_# Press [Enter] to enable/disable specific memory channel. BIOS Setup - 115 -...
  • Page 114 5-3-3-2-3 Refresh Management (RFM) Parameter Description Refresh Management (RFM) Configure Refresh Management. Refresh Management Options available: Enable, Disable, Auto, Force Enable. Default setting is Auto. RAA Initial Management Override Rolling Accumulated ACT Initial Management Threshold. Threshold Options available: 32, 40, 48, 56, 64, 72, 80, Auto. Default setting is Auto. RAA Maximum Management Override Rolling Accumulated ACT Maximum Management Threshold.
  • Page 115 5-3-3-3 DDR MBIST Options Parameter Description DDR MBIST Options Enable/Disable the Memory MBIST function. MBIST Enable Options available: Enabled/Disabled. Default setting is Disabled. Selects MBIST Test Mode. Interface Mode: Tests Single and Multiple CS transactions and Basic Connectivity. MBIST Test Mode (Note1) Data Eye Mode: Measures Voltage vs.
  • Page 116 Parameter Description For DRAM errors found in the BIOS memory BIST select tje repair type. PMU Mem BIST Algprithm Options available: Soft, Repair, Hard Repair, No Rrepairs -Test only.. DDR Healing BIST (Note2) Default setting is Soft Repair. BIOS Setup - 118 -...
  • Page 117 5-3-3-3-1 Data Eye Parameter Description Data Eye Pattern Select Options available: PRBS, SSO, Both. Default setting is PRBS. Pattern Length Determines the pattern length. The possible options are N=3..12. This item helps read the aggressors channels. Aggressor Channel Options available: Disabled, 1 Aggressor Channel, 3 Aggressor Channels, 7 Aggressor Channels.
  • Page 118 Parameter Description Target Static Lane Select This item is configurable when Target Static Lane Control is set to Upper 32 bits Enabled. Target Static Lane Select This item is configurable when Target Static Lane Control is set to Lower 32 bits Enabled.
  • Page 119 5-3-3-4 DDR RAS Parameter Description DDR RAS Enable/Disable the Data Poisoning function. Data Poisoning Options available: Auto, Enabled, Disabled. Default setting is Auto. Enable/Disable the DRAM Boot Package Repair function. DRAM Boot Time Package Repair Options available: Enable/Disable. Default setting is Disable. DRAM Runtime Post Package Enable/Disable the DRAM Runtime Post Package Repair function.
  • Page 120 Parameter Description Press [Enter] to configure advanced items. DRAM ECC Symbol Size Š – Configures the DRAM ECC Symbol Size. – Options available: Auto, x4, x8, x16. Default setting is Auto. DRAM ECC Enable Š – Enable/Disable DRAM ECC. When set to Auto, it will set ECC to enable.
  • Page 121 Press [Enter] to configure advanced items. DRAM ECS Mode Š – Options available: Auto, AutoECS, Manual1EECS, DisableECS. Default setting is Auto. DRAM Redirect Scrubber Enable Š – Options available: Auto, Enabled, Disabled. Default setting is Auto. DRAM Scrub Redirection Limit Š...
  • Page 122 5-3-3-5 DDR Bus Configuration Parameter Description DDR Bus Configuration Select the DRAMs On-die Termination impedance for RTT_NOM_WR. Dram ODT impedance RTT_ Options available: Auto, RTT_OFF, RZQ (240), RZQ/2 (120), RZQ/3 (80) NOM_WR RZQ/4 (60), RZQ5/(40), RZQ6/(20), RZQ7/(34). Default setting is Auto. Select the DRAMs On-die Termination impedance for RTT_NOM_RD.
  • Page 123 Parameter Description Select the ODT impedance for all DBYTE IOs. Options available: Auto, High Impedance, 480 ohm, 240 ohm, 160 ohm, Processor ODT impedance 120 ohm, 96 ohm, 80 ohm, 68.6 ohm, 60 ohm, 53.3 ohm,48 ohm, 43.6 ohm, 40 ohm, 36.9 ohm, 34.3 ohm, 32 ohm, 30 ohm, 28.2 ohm, 26.7 ohm, 25.3 ohm.
  • Page 124 5-3-3-6 Enforce POR Parameter Description DDR Training Options Press [Enter] to configure the Plan of Record (POR) to enable / disable Enforce POR restrictions for DDR5 frequency and voltage programming. Memory speeds will be capped at AMD guidelines. BIOS Setup - 126 -...
  • Page 125 5-3-3-7 DDR Training Options Parameter Description DDR Training Options Specify PDA enumeration mode. DRAM PDA Enumerate ID Options available: Auto, Toggling PDA enumeration mode, Legacy PDA Programming enumeration mode. Default setting is Auto. BIOS Setup - 127 -...
  • Page 126 5-3-3-8 DDR Security Parameter Description Security Enable/Disable Transparent SME. TSME Options available: Auto, Enabled, Disabled. Default setting is Auto. Options available: AES-128, AES-256. Default setting is AES-256. Enable/Disable Data Scrambling. Data Scramble Options available: Enabled, Disabled. Default setting is Enabled. Options available: Enabled, Disabled.
  • Page 127 5-3-3-9 DDR PMIC Configuration Parameter Description DDR PMIC Configuration Enables support for PMIC Error Reporting. PMIC Error Reporting Options available: Auto, False, True. Default setting is Auto. Options available: Secure Mode, Programming Mode. PMIC Operation Mode Default setting is Programming Mode. Options available: Always, Never, Once.
  • Page 128 5-3-3-10 DDR Miscellaneous Parameter Description DDR Miscellaneous DRAM Survives Warm Reset Options available: Enabled, Disabled. Default setting is Enabled. ODTS CMD Throttle Threshold Options available: Auto, 85'C, 90'C, 95'C. Default setting is Auto. BIOS Setup - 130 -...
  • Page 129 5-3-3-11 DDR PHY (CMN) Parameter Description DDR PHY (CMN) Options available: Auto, Enabled, Disabled. Default setting is Auto. Periodic Training BIOS Setup - 131 -...
  • Page 130 5-3-4 NBIO Common Options BIOS Setup - 132 -...
  • Page 131: Nbio Common Options

    Parameter Description NBIO Common Options Enable/Disable the IOMMU function. IOMMU Options available: Disabled, Enabled. Default setting is Enabled. Enable/Disable DMAr system protection during POST. DMAr Support Options available: Disabled, Enabled, Auto. Default setting is Auto. Enable/Disable DMA remap support in IVRS IVinfo Field. DMA Protection Options available: Auto, Enabled, Disabled.
  • Page 132 Parameter Description Enable/Disable the data link feature capability. Data Link Feature Cap Options available: Enabled, Disabled, Auto. Default setting is Auto. Enable/Disable the running PCIE CV tool support. CV test Options available: Auto, Enabled, Disabled. Default setting is Auto. Enable/Disable the SEV-SNP support. SEV-SNP Support Options available: Disable, Enable.
  • Page 133 5-3-4-1 SMU Common Options Parameter Description SMU Common Options TDP Control Options available: Manual, Auto. Default setting is Auto. PPT Control Options available: Manual, Auto. Default setting is Auto. Selects use the fused Determinism or set customized Determinism. Determinism Control Options available: Manual, Auto.
  • Page 134 Parameter Description Options available: Disabled, Enabled, Auto. Default setting is Auto. CPPC Preferred Cores Enable/Disable the HSMP support. HSMP Support Options available: Disabled, Enabled, Auto. Default setting is Auto. SVI3 SVC Speed Control Options available: Auto, Manual. Default setting is Auto. Options available: Auto, Disable, 1 stack, 2 stack, 4 stack.
  • Page 135 5-3-4-2 NBIO RAS Common Options Parameter Description NBIO RAS Common Options NBIO RAS Control Options available: Disabled, MCA, Auto. Default setting is Auto. Configures the Egress Poison High Severity. Each bit set to 1 enables Egress Poison Severity High High severity on the associated IOHC egress port. A bit of 0 indicates LOW severity.
  • Page 136 Parameter Description Uncorrected Converted to Enables mask for masking of uncorrectable parity errors on internal Poison Enable Mask High arrays. Uncorrected Converted to Enables mask for masking of uncorrectable parity errors on internal Poison Enable Mask Low arrays. Specifies the timer interval of the SYSHUB Watchdog timer in System Hub Watchdog Timer milliseconds.
  • Page 137 5-3-4-3 nBif Common Options Parameter Description SRIOV Š – Options available: Auto, Disable, Enable. Default setting is Auto. Š – Options available: Auto/Default, Disable, Enable. Default setting is Auto/Default. Š – Options available: Auto, Disable, Enable. Default setting is Auto. Š...
  • Page 138 Parameter Description ACS Rcc_Dev0 Š – Options available: Auto, Disable, Enable. Default setting is Auto. AER Rcc_Dev0 Š – Options available: Auto, Disable, Enable. Default setting is Auto. DlfEnableStrap1 Š – Options available: Auto, Disable, Enable. Default setting is Auto. Phy16GTStrap1 Š...
  • Page 139 Parameter Description RCC_DEV0 EXTENDED_FMT Š (continued) – Options available: Auto, Disable, Enable. Default setting is Auto. BIOS Setup - 141 -...
  • Page 140 5-3-4-4 Link EQ Present Options Parameter Description Link EQ Present Options Press [Enter] for configuration of advanced items. GEN3 Present Search Mask Configuration Š – Options available: Auto, Custom, Enable. Default setting is Auto. Press [Enter] for configuration of advanced items. GEN4 Present Search Mask Configuration Š...
  • Page 141: Fch Common Options

    5-3-5 FCH Common Options Parameter Description FCH Common Options I3C/I2C Configuration Options Press [Enter] for configuration of advanced items. SATA Configuration Options Press [Enter] for configuration of advanced items. USB Configuration Options Press [Enter] for configuration of advanced items. AC Power Loss Options Press [Enter] for configuration of advanced items.
  • Page 142 5-3-5-1 I3C/I2C Configuration Options Parameter Description I3C/I2C Configuration Options Options available: Both Disabled, I3C Enabled, I2C Enabled, Auto. I3C/I2C 0/1/2/3 Enable Default setting is Auto. I2C 4/5 Enable Options available: Disabled, Enabled, Auto. Default setting is Auto. Release SPD Host Control Options available: Disabled, Enabled, Auto.
  • Page 143 5-3-5-2 SATA Configuration Options Parameter Description SATA Configuration Options Enable/Disable OnChip SATA controller. SATA Enable Options available: Disabled, Enabled, Auto. Default setting is Auto. SATA RAS Support Options available: Disabled, Enabled, Auto. Default setting is Auto. SATA Staggered Spin-up Options available: Disabled, Enabled, Auto. Default setting is Auto. SATA Disabled AHCI Prefetch Options available: Disabled, Enabled, Auto.
  • Page 144 5-3-5-3 USB Configuration Options Parameter Description USB Configuration Options Enable/Disable USB controller. XHCI Controller0/1 enable Options available: Enabled, Disabled, Auto. Default setting is Auto. USB ecc SMI Enable Options available: Enable, Off, Auto. Default setting is Auto. Press [Enter] for configuration of advanced items. MCM USB enable XHCI2/ XHCI3 enable (Socket1) Š...
  • Page 145 5-3-5-4 AC Power Loss Options Parameter Description AC Power Loss Options Selects the AC Loss Control Method. AC Loss Control Options available: Power Off, Power On, Last State. Default setting is Last State. BIOS Setup - 147 -...
  • Page 146 5-3-5-5 Uart Configuration Options Parameter Description Uart Configuration Options Uart 0/1/2/3 Enable Options available: Disabled, Enabled, Auto. Default setting is Auto. BIOS Setup - 148 -...
  • Page 147 5-3-5-6 ESPI Configuration Options Parameter Description ESPI Configuration Options ESPI Enable Options available: Disabled, Enabled, Auto. Default setting is Auto. BIOS Setup - 149 -...
  • Page 148 5-3-5-7 FCH RAS Options Parameter Description FCH RAS Options Enable/Disable the ALink RAS Support. ALink RAS Support Options available: Disabled, Enabled, Auto. Default setting is Auto. Enables AB to forward downstream sync-flood message to system Reset After Sync Flood controller. Options available: Enable, Disable, Auto.
  • Page 149 5-3-5-8 Miscellaneous Options Parameter Description Miscellaneous Options Enable/Disable Boot Timer. Boot Timer Enable Options available: Disabled, Enabled, Auto. Default setting is Auto. BIOS Setup - 151 -...
  • Page 150: Soc Miscellaneous Control

    5-3-6 SOC Miscellaneous Control Parameter Description SOC Miscellaneous Control Enable/Disable the ConsoleOut function for ABL. ABL Console Out Control (Note) Options available: Disable, Enable, Auto. Default setting is Auto. ABL Console Out Serial Options available: eSPI, SOC UART0, SOC UART1, Auto. Default setting is Auto.
  • Page 151 Press [Enter] for configuration of advanced items. FAR enforcement state Š – Default setting is Enabled. Firmware Anti-rollback (FAR) SPL value in the CPU Fuse Š SPL value in the SPL table Š FAR Switch Š – Options available: Disabled, Enabled, Auto. Default setting is Auto. BIOS Setup - 153 -...
  • Page 152: Cxl Common Options

    5-3-7 CXL Common Options Parameter Description CXL Common Options Options available: Auto, Enabled, Disabled. Default setting is Auto. CXL Control Options available: Auto, Enabled, Disabled. Default setting is Auto. CXL SPM CXL Encryption Options available: Enabled, Disabled. Default setting is Disabled. Options available: Auto, Enabled, Disabled.
  • Page 153: Amd Pbs Menu

    AMD PBS Menu AMD PBS Option menu displays submenu options for configuring the function of AMD PBS. Select a submenu item, then press [Enter] to access the related submenu screen. Parameter Description Press [Enter] for configuration of advanced items. Enable/Disable SPI Locking for protect ROM part. SPI Locking Options available: Disabled, Enabled.
  • Page 154: Ras

    5-4-1 RAS Parameter Description Enable/Disable the Periodic SMI for polling [MCA Threshold] error. RAS Periodic SMI Control Options available: Disabled, Enabled. Default setting is Enabled. SMI Threshold Configures the SMI Threshold value. SMI Scale Configures the SMI Scale value. Defines the unit of time scale. SMI Scale Unit Options available: millisecond, second, minute.
  • Page 155 Parameter Description PCIe Root Port UnCorr Err Initialize the PCIe AER Uncorrected Error Mask register of Root Port. Mask Reg PCIe Root Port UnCorr Err Initialize the PCIe AER Uncorrected Error Severity register of Root Port. Sev Reg PCIe Device Corr Err Mask Initialize the PCIe AER Corrected Error Mask register of PCIe device.
  • Page 156: Cxl Range Encryption

    5-4-2 CXL Range Encryption Parameter Description Range_# Enter memory base address and limit address. Range_# Memory Base Start CXL Range Encryption Start to encrypt all memory ranges. BIOS Setup - 158 -...
  • Page 157: Chipset Setup Menu

    Chipset Setup Menu Chipset Setup menu displays submenu options for configuring the function of the North Bridge. Select a submenu item, then press <Enter> to access the related submenu screen. Parameter Description PCIe Link Training Type Options available: 1 Step, 2 Step. Default setting is 1 Step. Options available: Off, On.
  • Page 158: North Bridge

    5-5-1 North Bridge Parameter Description North Bridge Configuration Memory Information Total Memory Displays the total memory information. CPU 0/1 Information Press [Enter] to view information related to CPU 0/1. BIOS Setup - 160 -...
  • Page 159 5-5-2 Fabric Resource BIOS Setup - 161 -...
  • Page 160: Fabric Resource

    Parameter Description Fabric Resource CPU 0/1 NBIO_# PCIe Bus Change CPU 0/1 NBIO_# PCIe Bus Number. Number Change CPU 0/1 NBIO_# Prefetchable MMIO Above 4G Size. Prefetchable Mmio Above 4G Options available: System Default, 0, 1G, 2G, 4G, 8G, 16G, 32G, 64G, size 128G, 256G, 512G, 1T, 2T, 4T, 8T.
  • Page 161: Server Management Menu

    Server Management Menu Parameter Description Enable/Disable FRB-2 timer (POST timer). FRB-2 Timer Default setting is Enabled. Configures the FRB2 Timer timeout. FRB-2 Timer Options available: 3 minutes, 4 minutes, 5 minutes, 6 minutes. Default setting is 6 timeout minutes. Configures the FRB2 Timer policy. FRB-2 Timer Policy Options available: Do Nothing, Reset, Power Down, Power Cycle.
  • Page 162 Parameter Description System Event Log Press [Enter] to configure advanced items. View FRU Press [Enter] to view the FRU information. Information BMC network Press [Enter] to configure advanced items. configuration IPv6 BMC Network Press [Enter] to configure advanced items. Configuration BIOS Setup - 164 -...
  • Page 163: System Event Log

    5-6-1 System Event Log Parameter Description Enabling / Disabling Options Change this item to enable or disable all features of System Event SEL Components Logging during boot. Options available: Disabled, Enabled. Default setting is Enabled. Erasing Settings Choose options for erasing SEL. Erase SEL Options available: No/Yes, On next reset/Yes, On every reset.
  • Page 164 5-6-2 View FRU Information The FRU page is a simple display page for basic system ID information, as well as System product information. Items on this window are non-configurable. (Note) The model name will vary depends on the product you purchased BIOS Setup - 166 -...
  • Page 165: Bmc Network Configuration

    5-6-3 BMC Network Configuration Parameter Description BMC network configuration Lan Channel 1 Selects to configure LAN channel parameters statically or dynamically (DHCP). Do nothing option will not modify any BMC network parameters Configuration Address source during BIOS phase. Options available: Unspecified, Static, DynamicBmcDhcp. Default setting is DynamicBmcDhcp.
  • Page 166: Ipv6 Bmc Network Configuration

    5-6-4 IPv6 BMC Network Configuration Parameter Description IPv6 BMC network configuration IPv6 BMC Lan Channel 1 Enable/Disable IPv6 BMC LAN channel function. When this item is disabled, the system will not modify any BMC network during BIOS IPv6 BMC Lan Option phase.
  • Page 167: Security Menu

    Security Menu The Security menu allows you to safeguard and protect the system from unauthorized use by setting up access passwords. There are two types of passwords that you can set: • Administrator Password Entering this password will allow the user to access and change all settings in the Setup Utility. •...
  • Page 168: Secure Boot

    5-7-1 Secure Boot The Secure Boot submenu is applicable when your device is installed the Windows 8 (or above) operating ® system. Parameter Description System Mode Displays if the system is in User mode or Setup mode. Enable/ Disable the Secure Boot function. Secure Boot Options available: Enabled, Disabled.
  • Page 169 Parameter Description Press [Enter] to configure advanced items. Please note that this item is configurable when Secure Boot Mode is set to Custom. Factory Key Provision Š – Allows to provision factory default Secure Boot keys when system is in Setup Mode.
  • Page 170: Boot Menu

    Boot Menu The Boot menu allows you to set the drive priority during system boot-up. BIOS setup will display an error message if the legacy drive(s) specified is not bootable. Parameter Description Boot Configuration Number of seconds to wait for setup activation key. 65535 (0xFFFF) Setup Prompt Timeout means indefinite waiting.
  • Page 171 Parameter Description Selects the boot mode. Boot mode select Options available: LEGACY, UEFI. Default setting is UEFI. FIXED BOOT ORDER Priorities Press [Enter] to configure the boot priority. By default, the server searches for boot devices in the following sequence: Boot Option #1 / #2 / #3 / #4 / Hard drive.
  • Page 172: Save & Exit Menu

    Save & Exit Menu The Save & Exit menu displays the various options to quit from the BIOS setup. Highlight any of the exit options then press <Enter>. Parameter Description Save Options Saves changes made and closes the BIOS setup. Save Changes and Exit Options available: Yes, No.
  • Page 173: Bios Recovery

    5-10 BIOS Recovery The system has an embedded recovery technique. In the event that the BIOS becomes corrupt the boot block can be used to restore the BIOS to a working state. To restore your BIOS, please follow the instructions listed below: Recovery Instruction: 1.
  • Page 174: Bios Post Beep Code (Ami Standard)

    5-11 BIOS POST Beep code (AMI standard) 5-11-1 PEI Beep Codes # of Beeps Description Memory not Installed. Memory was installed twice (InstallPeiMemory routine in PEI Core called twice) Recovery started DXEIPL was not found DXE Core Firmware Volume was not found Recovery failed S3 Resume failed Reset PPI is not available...