Advertisement

Quick Links

SYSTEM Inverter Air Conditioners
MODELS
BEV unit
BEVQ50MVE
READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.
KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.
LESEN SIE DIESE ANWEISUNGEN VOR DER INSTALLATION SORGFÄLTIG DURCH.
BEWAHREN SIE DIESE ANLEITUNG FÜR SPÄTERE BEZUGNAHME GRIFFBEREIT AUF.
LIRE SOIGNEUSEMENT CES INSTRUCTIONS AVANT L'INSTALLATION.
CONSERVER CE MANUEL A PORTEE DE MAIN POUR REFERENCE ULTERIEURE.
LEA CUIDADOSAMENTE ESTAS INSTRUCCIONES ANTES DE INSTALAR.
GUARDE ESTE MANUAL EN UN LUGAR A MANO PARA LEER EN CASO DE TENER
ALGUNA DUDA.
PRIMA DELL'INSTALLAZIONE LEGGERE ATTENTAMENTE QUESTE ISTRUZIONI.
TENERE QUESTO MANUALE A PORTATA DI MANO PER RIFERIMENTI FUTURI.
ÄΙΑΒΑΣΤΕ ΠΡΟΣΕΚΤΙΚΑ ΑΥΤΕΣ ΤΙΣ ΟÄΗΓΙΕΣ ΠΡΙΝ ΑΠΟ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ ΕΧΕΤΕ ΑΥΤΟ
ΤΟ ΕΓΧΕΙΡΙÄΙΟ ΕΥΚΑΙΡΟ ΓΙΑ ΝΑ ΤΟ ΣΥΜΒΟΥΛΕΥΕΣΤΕ ΣΤΟ ΜΕΛΛΟΝ.
LEES DEZE INSTRUCTIES ZORGVULDIG DOOR VOOR INSTALLATIE. BEWAAR DEZE HAN-
DLEINDING WAAR U HEM KUNT TERUGVINDEN VOOR LATERE NASLAG.
LEIA COM ATENÇÃO ESTAS INSTRUÇÕES ANTES DE REALIZAR A INSTALAÇÃO.
MANTENHA ESTE MANUAL AO SEU ALCANCE PARA FUTURAS CONSULTAS.
ПЕРЕД НАЧАЛОМ МОНТАЖА ВНИМАТЕЛЬНО ОЗНАКОМЬТЕСЬ С ДАННЫМИ
ИНСТРУКЦИЯМИ. СОХРАНИТЕ ДАННОЕ РУКОВОДСТВО В МЕСТЕ, УДОБНОМ ДЛЯ
ОБРАЩЕНИЯ В БУДУЩЕМ.
INSTALLATION MANUAL
English
Deutsch
Français
Español
Italiano
ΕλληνικÜ
Nederlands
Portugues
Russian

Advertisement

Table of Contents
loading

Summary of Contents for Daikin BEV Series

  • Page 1 INSTALLATION MANUAL English SYSTEM Inverter Air Conditioners Deutsch MODELS Français BEV unit BEVQ50MVE Español Italiano ΕλληνικÜ READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE. LESEN SIE DIESE ANWEISUNGEN VOR DER INSTALLATION SORGFÄLTIG DURCH. Nederlands BEWAHREN SIE DIESE ANLEITUNG FÜR SPÄTERE BEZUGNAHME GRIFFBEREIT AUF.
  • Page 2 3P109591-1C...
  • Page 3: Table Of Contents

    BEVQ50MVE VRV SYSTEM Inverter Air Conditioners Installation manual CONTENTS 1 SAFETY CONSIDERATIONS ..................1 2 BEFORE INSTALLATION ....................2 3 SELECTING INSTALLATION SITE................4 4 PREPARATIONS BEFORE INSTALLATION ..............6 5 BEV UNIT INSTALLATION ....................7 6 REFRIGERANT PIPING WORK ..................7 7 ELECTRIC WIRING WORK ..................10 8 WIRING EXAMPLE AND HOW TO SET THE REMOTE CONTROLLER....12 9 HOW TO ATTACH THE NAMEPLATE ................15 10 TEST OPERATION ......................15...
  • Page 4: Before Installation

    • Make sure that a separate power supply circuit is provided for this unit and that all electrical work is carried out by qualified personnel according to local laws and regulations and this installation manual. An insufficient power supply capacity or improper electrical construction may lead to electric shocks or fire. •...
  • Page 5 • BEV unit may only be connected to the models shown in the table below. Do not attempt connection with other models. Indoor unit Model Wall-mounted type FXAQ20MHV1, FXAQ25MHV1, FXAQ32MHV1, FXAQ40MHV1, FXAQ50MHV1 • See the included installation manuals on the VRV outdoor unit and the indoor unit for details. •...
  • Page 6: Selecting Installation Site

    FOR THE FOLLOWING ITEMS, TAKE SPECIAL CARE DURING CONSTRUCTION AND CHECK AFTER INSTALLATION IS FINISHED. a. Items to be checked after completion of work Items to be checked If not properly done, what is likely to occur Check Are the indoor and outdoor and BEV unit fixed firmly? The units may drop, vibrate or make noise.
  • Page 7 When hanging the unit from the ceiling Install so that the control box lid is facing down. Direction of the gas piping connection piping Horizontal position Maintenance hole 450 or more Take the gas piping thermistor out from above. Be sure to create a maintenance hole the size shown in the figure above.
  • Page 8: Preparations Before Installation

    4. PREPARATIONS BEFORE INSTALLATION When hanging the unit from the ceiling (1) Check the relative locations of ceiling hole, unit, and hanging bolts. <Example of installation> Ceiling slab (Suspension bolt pitch) Anchor Long nut or turnbuckle Suspension bolt BEV unit proper Note: All the above parts are field supplied.
  • Page 9: Bev Unit Installation

    5. BEV UNIT INSTALLATION Use only accessories and parts which are of the designated specification when installing. When hanging the unit from the ceiling When installing the unit on a wall (1) Temporarily install the BEV unit. (1) Mount the hanging fittings with the Mount the hanging fittings to mounting screws (4 pieces).
  • Page 10 • When connecting the flare nut, coat the flare both inside and outside with ester oil or ether oil and initially tighten by hand 3 or 4 turns before tightening firmly. • Refer to the Table 1 to determine the proper tightening torque. Table 1 Pipe size Tightening torque...
  • Page 11 Cut any extra line off after tightening it. Insulation for Liquid piping fitting (4) (accessory) Insulation for fitting (3) (accessory) Cut any extra line off Flare nut after tightening it. Clamp (2) Piping union (accessory) Clamp (2) Flare nut (accessory) Flare nut Piping union Cut any extra line off...
  • Page 12: Electric Wiring Work

    Piping connection procedure • Make sure the length of the refrigerant piping between the BEV unit and the indoor unit is no more than 15m and that the difference in height is at least 4m. (1) Connection example for the indoor unit •...
  • Page 13 • All wiring must be performed by an authorized electrician. • One BEV unit is connected to one indoor unit. Mark each indoor unit and BEV unit as unit A, unit B..., and be sure the terminal block wiring to the outdoor unit are properly matched. If wiring and piping between the outdoor unit and an indoor unit and BEV unit are mismatched, the system may cause a malfunction.
  • Page 14: Wiring Example And How To Set The Remote Controller

    8. WIRING EXAMPLE AND HOW TO SET THE REMOTE CONTROLLER 8-1 HOW TO CONNECT WIRINGS • Connect the piping only after finishing the refrigerant piping work. • Make sure all power supply is shut down to the unit first. • As shown in the Fig. 16, loosen the two screws in the control box lid, remove it, and do the wiring work. •...
  • Page 15 [ PRECAUTIONS ] 1. Use round crimp-style terminals for connecting wiring to the power supply terminal block. If unavailable, observe the following points when wiring. • Do not connect wiring of different gauge to the same power supply terminal. (Looseness in the connection may cause overheating.) •...
  • Page 16 1. When using 1 remote controller for 1 indoor unit. (Normal operation) Power supply Power supply Power supply Power supply 220-240V 220-240V 220-240V 220-240V Outdoor unit 50Hz 50Hz 50Hz 50Hz Control box IN/D OUT/D TO indoor TO indoor TO indoor 1 2 3 F 1 2 3 F BEV Unit A...
  • Page 17: How To Attach The Nameplate

    8-4 DEFAULT SETTINGS 1. Once piping work is completed, conduct the following settings as needed. For BEV unit-only systems The Cool/Heat SELECTOR is needed. Refer to the installation manual included with the Cool/Heat SELECTOR for details on how to set it. 2.
  • Page 18 3P084604-3C EM04A023 (0408)

This manual is also suitable for:

Bevq50mve

Table of Contents