Grizzly G9743 Owner's Manual page 7

7"x12" gearhead metal-cutting bandsaw
Hide thumbs Also See for G9743:
Table of Contents

Advertisement

Downfeed
Figure 4. Feed controls.
L.
Feed Rate Dial: Adjusts feed rate between
levels 1–9. Increases feed rate when turned
counterclockwise and decreases feed rate
when turned clockwise.
M. Feed On/Off Valve: Opens to lower head-
stock until it contacts downfeed stop bolt;
closes to stop headstock from lowering.
N
Figure 5. Other downfeed components.
N. Downfeed Stop Bolt: Stops headstock from
lowering farther than completion of cut.
O. Downfeed Limit Switch: Turns machine
OFF when headstock is fully lowered and
switch is engaged.
Model G9743 (Mfd. Since 10/23)
L
M
O
Power Controls
R
Figure 6. Control panel components.
P. ON Button: Starts saw blade.
Q. Emergency Stop Button: Stops all machine
functions. Twist clockwise to reset.
R. Pump ON/OFF Switch: Turns coolant pump
ON when moved up and OFF when moved
down.
S
Figure 7. Location of circuit breaker reset button.
S. Circuit Breaker Reset Button: Allows motor
to be restarted after thermal overload protec-
tion has tripped. To reset, turn motor OFF,
wait a few minutes for motor to cool, then
press reset button. If button does not stay
depressed, allow motor to cool longer, then
try again.
P
Q
-5-