Trane Wall Sleeve and Grille

The image below shows the typical unit components
that are ordered and installed.
I I m m p p o o r r t t a a n n t t : : Proper installation is the responsibility of
the installer. Product failure due to
improper installation is not covered under
warranty.
N N o o t t e e : : To install the Trane Wall Sleeve and Grille, refer
to the latest installation instructions, PTAC-
SVN028 and PTAC-SVN027.

Considerations for Use of Existing

Sleeves

W W A A R R N N I I N N G G
L L i i v v e e E E l l e e c c t t r r i i c c a a l l C C o o m m p p o o n n e e n n t t s s ! !
F F a a i i l l u u r r e e t t o o f f o o l l l l o o w w a a l l l l e e l l e e c c t t r r i i c c a a l l s s a a f f e e t t y y p p r r e e c c a a u u t t i i o o n n s s
w w h h e e n n e e x x p p o o s s e e d d t t o o l l i i v v e e e e l l e e c c t t r r i i c c a a l l c c o o m m p p o o n n e e n n t t s s c c o o u u l l d d
r r e e s s u u l l t t i i n n d d e e a a t t h h o o r r s s e e r r i i o o u u s s i i n n j j u u r r y y . .
W W h h e e n n i i t t i i s s n n e e c c e e s s s s a a r r y y t t o o w w o o r r k k w w i i t t h h l l i i v v e e e e l l e e c c t t r r i i c c a a l l
c c o o m m p p o o n n e e n n t t s s , , h h a a v v e e a a q q u u a a l l i i f f i i e e d d l l i i c c e e n n s s e e d d e e l l e e c c t t r r i i c c i i a a n n
o o r r o o t t h h e e r r i i n n d d i i v v i i d d u u a a l l w w h h o o h h a a s s b b e e e e n n p p r r o o p p e e r r l l y y t t r r a a i i n n e e d d
i i n n h h a a n n d d l l i i n n g g l l i i v v e e e e l l e e c c t t r r i i c c a a l l c c o o m m p p o o n n e e n n t t s s p p e e r r f f o o r r m m
t t h h e e s s e e t t a a s s k k s s . .
14
In applications when the unit is a replacement, it is
recommended to use a Trane sleeve. This unit can be
retrofitted to other manufacturers similar sleeves if
outdoor unit airflow is not restricted or recirculated.
I I m m p p o o r r t t a a n n t t : : Ensure the outdoor grille is installed on the
sleeve. For any sleeve retrofit applications,
be sure that the foam seals (factory
installed on the tube sheets) provide a
good seal between the grille and outdoor
coil tube sheets. These foam seals provide
a barrier that stops the inside air from
mixing with the outside air (known as air
recirculation).
I I m m p p o o r r t t a a n n t t : : Inspect the wall sleeve thoroughly prior to
installation. The manufacturer does not
assume responsibility for costs or damage
due to defects in the sleeve or for improper
installation.
Remove any existing foam
baffles installed on
competitor's outdoor grille.
General Electric Metal Wall
Sleeve; interchangeable with
ProSpace wall sleeve.
General Electric Plastic Wall
Sleeve; remove bottom seal
from plastic sleeve.