OUTPUTS
Programming Items
Show Summary
Output Summary
Left Valve
Left Valve Test
Test OR Calibrate
L. Valve Calib
'' ''
'' ''
L. Bypass Valve
Left Bypass
Test OR Calibrate
Valve Test
If bypass option availble
L. Bypass Valve
'' ''
'' ''
Calib
Left Valve display is only for CBS-2102XTS dual side brewer. CBS-2101XTS Single series displays RIGHT SIDE only
Right Valve
Right Valve Test
Test OR Calibrate
R. Valve Calib
'' ''
'' ''
R. Bypass Valve
Right Bypass
Test OR Calibrate
Valve Test
If bypass option availble
R. Bypass
'' ''
'' ''
Valve Calib
Fill Valve
Fill Valve Test
Left brew basket
Left Basket Lk.
lock test
Not on CBS 2130XTS
Right brew
Right Basket Lk.
basket lock test
Not on CBS 2130XTS
Heater
Heater Test
Screen
Screen Contrast
Brightness OR Contrast
S. Brightness
Default-factory set Flow Rates; Brew Valve and Bypass
See "OUTPUTS" right and left brew valve and bypass valve settings and calibration
CBS-2152 & CBS-2162 ml/min
Left Brew FR
Left Bypass FR
Right Brew FR
Right Bypass FR
CBS-2132& CBS-2142 ml/min
Left Brew FR
Left Bypass FR*
2150
Right Brew FR
Right Bypass FR
--------------------------------------------------------------------------------------------------------------------
Go to fetco.com for the latest versions of all information
Factory set Default
(Press to test)
Calibrate
*Flow Rate
(Press to test)
Calibrate
*Flow Rate
(Press to test)
Calibrate
*Flow Rate
(Press to test)
Calibrate
*Flow Rate
(Press to test)
(Press to test)
(Press to test)
(Press to test)
Contrast
Brightness
3200
2400
3200
2400
1540
2150
*
1540
2150
Programming Range (display)
Left Brew FR
Left Bypass FR
Right Brew FR
Right Bypass FR
Screen Contrast
Screen Brightness
TEST
Press To Test
1540 to 3200 ml p m
|_________[]________|
1400-2800
TEST
Press To Test
2150 to 2400 ml p m
|_________[]________|
1900-2100
TEST
Press To Test
1540 to 3200 ml p m
|_________[]________|
1400-2800
TEST
Press To Test
2150 to 2400 ml p m
|_________[]________|
1900-2100
TEST
Press To Test
TEST
Press To Test
TEST
Press To Test
TEST
Press To Test
|____________[]____|
1
|____________[]____|
1
CBS-2151& CBS-2161ml/min
Right Brew FR
3200
Right Bypass FR
2400
CBS-2131&CBS-2141 ml/min
*
Right Brew FR
1540
*
Right Bypass FR
Part A-User Guide & Operator instructions
Page 9
3200
2400
3200
2400
FR=Flow Rate ml/min
8
8
Touch To Return
Runs valve to verify
flow. Have container
TEST
under brew-basket!
Factory or service use
for flow rate adjustment
1950-3800
Runs valve to verify
flow. Have container
TEST
under brew-basket!
Factory or service use
for flow rate adjustment
2800
Runs Valve to verify flow.
Have container under
TEST
Factory or service use
1950-3800
Runs valve to verify
flow. Have container
TEST
under brew-basket!
Factory or service use
for flow rate adjustment
2800
Operates fill valve.
Have container under
TEST
both brew-baskets!
Energizes brew basket
lock. For factory or
TEST
Energizes brew basket
lock. For factory or
TEST
Energizes Heater(s)
TEST
Service use only.
8
10
8
10
P130 Part A Rev. 003 July 2019
Notes
brew-basket!
for flow rate
service use
service use