Fetco CBS-2100XTS Users Manual And Operator Instructions page 7

Extractor touch screen
Table of Contents

Advertisement

GENERAL
Programming Items
 Tank Temp.
"OFF" allows
 Brew at Temp.
brewing at any
temperature.
 Units of Meas.
Temperature
Volume
Energy
 ECO Mode
Saving Mode
 Logo Timeout
This is a
 Brew B. Sensor
Safety Feature
 Use Flowjet
"NORMAL" for
 LLC Sensitivity
most water
"HIGH" for R.O.
BREW AT TEMPERATURE DEFINITONS
--------------------------------------------------------------------------------
ON
BREW AT TEMP: "
"
(DEFAULT: FACTORY PROGRAMMED INTO BREWER)
"BREW START" Batch Section Pennants will not be accessible
until tank temperature is at set point.
The "BREW START" screens with the Batch Section Pennants
become accessible when hot water tank is at the selected
temperature. A screen (example to the right) will display
and show "BREW AT TEMP" is selected. 
--------------------------------------------------------------------------------
BREW AT TEMP: AUTO
"BREW START" will pause if the hot water tank is not at the
selected temperature—and automatically start when it is at the
set temperature.
If the temperature is too low, the brewer will wait until the proper
temperature is reached. A screen (example to the right) will
display showing a thermometer icon and the tank temperature.
IMPORTANT: ALWAYS have dispenser(s) under the brewer
when in the BREW AT TEMP mode
----------------------------------------------------------------------------------------------------------
OFF
BREW AT TEMP:
Allows brewing at any temperature above 170°F/82°C.
If Selected: Turns heaters off after 1 hour of inactivity.
The hot water tank temperature will slowly decline to no lower than 60°C/170°F
A screen (example to the right) will display showing "ECO Mode" is activated. 
To return from ECO-Mode
Tap the screen, ECO Mode turns off, and the brewer will heat to set temperature.
It takes approximately 7-15 minutes to return from 60°C/170°F to factory default 93°C/200°F
All FETCO commercial hot beverage equipment have well insulated hot water tanks and have
engineered mechanical features to limit energy consumption.
Effective construction and insulation increases equipment life and lowers building HVAC costs.
FETCO hot beverage equipment have the best energy savings of all major suppliers.
Go to fetco.com for the latest versions of all information
Factory set Default
200°F
"ON"
°C or °F
Gallons [Liters]
OFF
0:15 mm:ss
NORMAL
(SEE WARNINGS)
NO
NORMAL
USER SELECTABLE
USER SELECTABLE
ECO MODE-Energy saving mode DEFINITONS
Programming Range
[200 °F]
|______________[]___|
77C/170F
97C/207F
ON
|________[]_______|
OFF
ON AUTO
°F
|___[]____________|
°F
Gallons
|_____________[]__|
Gallons
Liters
ECO Mode
_______________[]_____
ON
0:15 mm:ss
|__[]___________|
0:15
NORMAL
|__[]____________|
NORMAL
OVERRIDE
NO
____[]_______________
NO
NORMAL
____[]______________
NORMAL
X
X
T
T
S
S
E
E
X
X
T
T
R
R
A
A
C
C
T
T
O
O
R
R
T
T
O
O
U
U
C
C
H
H
S
S
C
C
R
R
E
E
E
E
N
N
CBS 2100XTS
500
Ready
Tank Temp
1000
Heating
200
°F
2000
Filling
2500
3000
Regular 1
|■| 1:00
INFO
3500
 5:30
4000
Regular 2
|■| 1:00
4500
 5:30
Decaf 1
5000
200°F
|■| 1:00
5500
 5:30
Decaf 2
6000
|■| 1:00
STOP
 5:30
6500
7000
(Not recommended)
7500
8000
8500
Part A-User Guide & Operator instructions
Page 7
Notes
Chart to correct for
high altitude below
SEE NOTE BELOW!
[Switchable Units]
°C
[Switchable Units]
If Selected: After 1 hour of
inactivityLowers hot water
tank temperature to 170F
OFF
5:00
Factory or service use for
servicing. "NORMAL" is
recommended for safety.
Trims water handling
system for Flowjet
YES
Liquid level control sensitivity.
High is for reverse osmosis
water or very pure water.
HIGH
Chart to correct for altitude for boiling point
in tank water temperature.
Suggested
Boiling
Suggested
[ft]
[m]
Setting[°F]
point[°F]
Setting[°C]
0
0
205
212.0
96
152
205
211.0
96
305
200
210.1
93
610
200
208.1
93
762
200
207.2
93
914
200
206.2
93
1067
197
205.3
92
1219
195
204.3
91
1372
194
203.4
90
1524
194
202.4
90
1676
193
201.5
89
1829
192
200.6
89
1981
191
199.6
88
2134
190
198.7
87
2286
188
197.8
86
2438
187
196.9
86
2591
185
196.0
85
XTS
EXTRACTOR
TOUCHSCREEN
CBS 2100XTS
■ ECO
ਲ Heating
ਲ Filling
P130 Part A Rev. 003 July 2019
Boiling
point [°C]
100.0
99.5
98.9
97.8
97.3
96.8
96.3
95.7
95.2
94.7
94.2
93.6
93.1
92.6
92.1
91.6
91.1
Tank Temp
170
°F

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cbs-2141xtsCbs-2142xtsL4s-10

Table of Contents