Set the flow rates of components to adjust for taste profile and for over or under potting.
Built-in algorithms in Brewer controller software corrects brew parameter to customer preferences or to trim variations in flow control components
NOTICE: This operation requires operator hold finger on keypad position for one minute—without lifting it.
1) MEASURE THE FLOW RATE:
It is very important to calibrate a heated brewer, preferably a brewer that has been used for brewing.
-Enter programming mode, scroll left to "OUTPUTS"
-Scroll down to "Left(or)Right Valve Test"
-Place 5 liter/2gal measuring container under empty brew-basket.
One good way to measure is to weigh the test water. Use a scale for at least 5 kg/12lb
-Press To Test the Brew Valve. 
It is very important for this test to keep finger in place for the entire minute.
After one minute [1 min.]–calibration dispense will stop automatically.
Measure the results of the flow in the 5-liter measuring container and hold the number.
2) AUTOMATIC Built-in CALIBRATE THE FLOW RATE
-Enter this number, in milliliters, into the calibration slider for the Valve tested in the OUTPUT MENU.
-Use milliliters. If measured in fluid ounces (fl.oz) multiply by 29.57 to convert to milliliters
-After entering the measured volume, exit PROGRAMMING and return to the normal screens
3) MANUAL METHOD Operator input: CALIBRATE THE FLOW RATE
Use the amount measured, in milliliters, divided by programmed value and multiply by the current setting
 Example of
*
3200 ml p m
CBS-2160 brew
|_________[]________|
valve slider
2800
3800
*Current valve flow setting in milliliters per minute [mlpm] as shown in the value above slider in OUTPUT Flow Rate box-
Obtain programmed volume from "PROGRAM" Menu under "Batch Summary".
Note—match correct batch number to correct side, if two sided.
By entering the new flow rate number into the brewer, the software automatically corrects the valve flow discrepancy
See "OUTPUTS" right and left brew valve and bypass valve settings and calibration
CBS-2162
Left Brew FR
Left Bypass FR
Right Brew FR
Right Bypass FR
CBS-2152
Left Brew FR
Left Bypass FR
Right Brew FR
Right Bypass FR
CBS-2142
Left Brew FR
Left Bypass FR
Right Brew FR
Right Bypass FR
---------------------------------------------------------------------------------------------
CBS-2132
Left Brew FR
Right Brew FR
Go to fetco.com for the latest versions of all information

How to calibrate the flow rate

Keep finger on touchpad for one minute! !!DO NOT STOP!!
!
Actual Volume
Programmed Volume
Default-factory set Flow Rates; Brew Valve and Bypass
ml/min
3200
2400
3200
2400
ml/min
3200
2400
3200
2400
ml/min
1540
2150
1540
2150
CBS-2130XTS equipment do not have the BYPASSS feature
ml/min
1540
1540
Page 10
CURRENT
=
X
SETTING
SETTING
CBS-2161
ml/min
Right Brew FR
3200
Right Bypass FR
2400
CBS-2151
ml/min
Right Brew FR
3200
Right Bypass FR
2400
CBS-2141
ml/min
Right Brew FR
1540
Right Bypass FR
2150
CBS-2131
ml/min
Right Brew FR
1540
Part A-User Guide & Operator instructions
Enter new setting on the
NEW
slider shown and EXIT to
save
P130 Part A Rev. 003 July 2019