Gigabyte H261-H60 User Manual

Hci server – intel dp 2u 4 nodes server
Table of Contents

Advertisement

Quick Links

H261-H60
HCI Server – Intel DP 2U 4 Nodes Server
User Manual
Rev. 1.0

Advertisement

Table of Contents
loading

Summary of Contents for Gigabyte H261-H60

  • Page 1 H261-H60 HCI Server – Intel DP 2U 4 Nodes Server User Manual Rev. 1.0...
  • Page 2 GIGABYTE's prior written permission. Documentation Classifications In order to assist in the use of this product, GIGABYTE provides the following types of documentation:  User Manual: detailed information & steps about the installation, configuration and use of this product (e.g.
  • Page 3 Conventions The following conventions are used in this user's guide: NOTE! Gives bits and pieces of additional information related to the current topic. CAUTION! Gives precautionary measures to avoid possible hardware or software problems. WARNING! Alerts you to any damage that might result from doing or not doing specific actions.
  • Page 4 Server Warnings and Cautions Before installing a server, be sure that you understand the following warnings and cautions. WARNING! To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
  • Page 5 Electrostatic Discharge (ESD) CAUTION! ESD CAN DAMAGE DRIVES, BOARDS, AND OTHER PARTS. WE RECOMMEND THAT YOU PERFORM ALL PROCEDURES AT AN ESD WORKSTATION. IF ONE IS NOT AVAILABLE, PROVIDE SOME ESD PROTECTION BY WEARING AN ANTI-STATIC WRIST STRAP AT- TACHED TO CHASSIS GROUND -- ANY UNPAINTED METAL SURFACE -- ON YOUR SERVER WHEN HANDLING PARTS.
  • Page 6 pliers, never the wide sides. Gripping the wide sides can dam-age the contacts inside the jumper, causing intermittent problems with the function con-trolled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool used to remove a jumper, or the pins on the board may bend or break.
  • Page 7: Table Of Contents

    Table of Contents Chapter 1 Hardware Installation ................... 11 Installation Precautions .................. 11 Product Specifications ..................12 System Block Diagram ................... 16 Chapter 2 System Appearance ..................17 Front View ...................... 17 Rear View ....................... 17 Front Panel LED and Buttons ................ 18 Rear System LAN LEDs .................
  • Page 8 5-2-4 Serial Port Console Redirection ................47 5-2-5 COM1/COM2 Serial Over LAN/Legacy/Serial Port for Out-of-Band EMS ....Console Redirection Settings ....................48 5-2-6 SIO Configuration ....................51 5-2-7 PCI Subsystem Settings ..................54 5-2-8 Network Stack ......................55 5-2-9 CSM Configuration ....................56 5-2-10 Post Report Configuration ..................58 5-2-11 NVMe Configuration ....................59 5-2-12 USB Configuration ....................60 5-2-13 Chipset Configuration .....................61...
  • Page 9 Security Menu ....................101 5-5-1 Secure Boot ......................102 5-5-2 Key Management ....................103 Boot Menu ....................105 5-6-1 UEFI NETWORK Drive BBS Priorities ..............107 ............... 108 5-6-2 1UEFI Application Boot Priorities Save & Exit Menu ..................109 BIOS POST Codes ..................111 5-8-1 AMI Standard - PEI ....................
  • Page 10 This page intentionally left blank - 10 -...
  • Page 11: Chapter 1 Hardware Installation

    Chapter 1 Hardware Installation Installation Precautions The motherboard/system contain numerous delicate electronic circuits and components which can become damaged as a result of electrostatic discharge (ESD). Prior to installation, carefully read the service guide and follow these procedures: • Prior to installation, do not remove or break motherboard S/N (Serial Number) sticker or warranty sticker provided by your dealer.
  • Page 12: Product Specifications

    The maximum number of DCPMM that can be installed is based on a maximum operating (ambient) temperature of 35°C To enquire about installing a greater number of DCPMM, please consult with your GIGABYTE technical or sales representative Hardware Installation - 12 -...
  • Page 13 Per node: 1 x Dedicated management port Š Total: 4 x Dedicated management ports Š 1 x 10/100/1000 *CMC global management port Š Secur i t y Ser ver Oper ating P r oper t i es *CMC: Chassis Management Controller, to monitor all status of computing nodes * Please contact FAE if NCSI function of OCP mezzanine card is needed Power Suppl y Video...
  • Page 14 Per node: Front I/O 1 x Power button with LED Š 1 x ID button with LED Š 1 x Status LED Š Socket Secur i t y Ser ver Oper ating P r oper t i es Total: Power Suppl y 4 x Power button with LED Š...
  • Page 15 Power Supply 2 x 2200W redundant PSUs Š 80 PLUS Platinum Š Socket Secur i t y Ser ver Oper ating P r oper t i es AC Input: Power Suppl y 100-127V~/ 14A, 47-63Hz Š 200-240V~/ 12.6A, 47-63Hz Š DC Output: Š...
  • Page 16: System Block Diagram

    System Block Diagram Hardware Installation - 16 -...
  • Page 17: Chapter 2 System Appearance

    Chapter 2 System Appearance Front View Node 1 Node 2 Node 3 Node 4 Decription Front Panel LEDs and buttons • Please Go to Chapter 2-3 Front Panel LED and Buttons for detail description of function LEDs. Rear View Secondary Primary Decription Chassis management Console port...
  • Page 18: Front Panel Led And Buttons

    Front Panel LED and Buttons No. Name Color Status Description Green System is operating normally. Critical condition, may indicates: System fan failure System temperature Non-critical condition, may indicates: Amber System Redundant power module failure Blink Status LED Temperature and voltage issue Chassis intrusion Non-critical condition, may indicates: Redundant power module failure...
  • Page 19: Rear System Lan Leds

    Rear System LAN LEDs Name Color Status Description Yellow 10Gbps data rate 10GbE Green 1Gbps data rate Speed LED 100 Mbps data rate Link between system and 10GbE Green network or no access Link/ Blink Data transmission or receiving is occurring Activity LED No data transmission or receiving is occurring System Appearance...
  • Page 20: Power Supply Unit Led

    Power Supply Unit LED PSU LED State Description No AC power to all power supplies 0.5Hz Green Blinking AC present / only standby on / Cold redundant mode 2Hz Green Blinking Power supply firmware updateing mode AC cord unplugged or AC power lost; with a second power supply in parallel still with AC input power Amber Power supply critical event causing shut down:...
  • Page 21: Hard Disk Drive Leds

    Hard Disk Drive LEDs HDD Present RAID SKU Rebuilding LED1 Locate HDD Fault Access (No Access) Disk LED Green ON(*1) BLINK (*2) (LED on Back Panel) Amber No RAID configuration Green ON(*1) (via HBA) Removed HDD Slot (LED on Back Panel) Amber Green BLINK (*2)
  • Page 22 This page intentionally left blank System Appearance - 22 -...
  • Page 23: Chapter 3 System Hardware Installation

    Chapter 3 System Hardware Installation Pre-installation Instructions Computer components and electronic circuit boards can be damaged by discharges of static electricity. Working on computers that are still connected to a power supply can be extremely dangerous. Follow the simple guidelines below to avoid damage to your computer or injury to yourself.
  • Page 24: Removing Chassis Cover

    Removing Chassis Cover Before you remove or install the system cover • Make sure the system is not turned on or connected to AC power. Follow these instructions to remove the system cover: Loosen and remove the screws securing the back cover. Push down the indentation located at the side of the back chassis Slide the cover horizontally to the back and remove the cover in the direction of the arrow.
  • Page 25: Removing And Installing The Fan Duct

    Removing and Installing the Fan Duct Follow these instructions to remove/install the fan duct: Remove the screws. Lift up to remove the fan ducts To install the fan duct, align the fan duct with the guiding groove. Push down the fan duct into chassis until its firmly seats - 25 - Hardware Installation...
  • Page 26: Installing The Cpu And Heat Sink

    Installing the CPU and Heat Sink Read the following guidelines before you begin to install the CPU: • Make sure that the motherboard supports the CPU. • Always turn off the computer and unplug the power cord from the power outlet before installing the CPU to prevent hardware damage.
  • Page 27 WARNING! CPU0 and CPU1 use different CPU heat sinks. See the following image for using correct heat sink. Failure to observe the warning could result in damage to the equipment. Primary CPU Heat Sink: Secondary CPU Heat Sink: - 27 - Hardware Installation...
  • Page 28: Installing The Memory

    3-10 Installing the Memory Read the following guidelines before you begin to install the memory: • Make sure that the motherboard supports the memory. It is recommended that memory of the same capacity, brand, speed, and chips be used. • Always turn off the computer and unplug the power cord from the power outlet before installing the memory to prevent hardware damage.
  • Page 29: Installing A Memory

    3-10-2 Installing a Memory Before installing a memory module, make sure to turn off the computer and unplug the power cord from the power outlet to prevent damage to the memory module. Be sure to install DDR4 DIMMs on this motherboard. Follow these instructions to install the Memory: Insert the DIMM memory module vertically into the DIMM slot, and push it down.
  • Page 30: Intel Optane Dcpmm Dimm Population Rule

    3-10-4 Intel Optane DCPMM DIMM Population Rule Thermal conditions for DCPMM DIMM support: • The ambient temperature must be at or below 35°C • The Cascade Lake CPU used must have a maximum TDP of 165W • A maximum of 2 pcs 256G DCPMM may be installed (1 Node) •...
  • Page 31: Installing The Pci Expansion Card

    3-11 Installing the PCI Expansion Card • Voltages can be present within the server whenever an AC power source is connected. This voltage is present even when the main power switch is in the off position. Ensure that the system is powered-down and all power sources have been disconnected from the server prior to installing a PCI card.
  • Page 32: Installing The Hard Disk Drive

    3-12 Installing the Hard Disk Drive Read the following guidelines before you begin to install the Hard disk drive: • Take note of the drive tray orientation before sliding it out. • The tray will not fit back into the bay if inserted incorrectly. •...
  • Page 33: Replacing The Fan Assemblly

    3-13 Replacing the FAN Assemblly Follow these instructions to replace the fan assembly: Pull outward the fan ear. Lift up the fan assembly from the chassis. Reverse the previous steps to install the replacement fan assembly. - 33 - Hardware Installation...
  • Page 34: Replacing The Power Supply

    3-14 Replacing the Power Supply Before you remove or install the system cover • Make sure the system is not turned on or connected to AC power. Follow these instructions to replace the power supply: Remove the four screws securing on the power supply. Pull up the power supply handle and press the retaining clip on the right side of the power supply along the direction of the arrow.
  • Page 35: Replacing Power Distribution Board Cage

    3-15 Replacing Power Distribution Board Cage Before you remove or install the power distribution board cage: • Make sure the system is not turned on or connected to AC power. Follow these instructions to remove the power distribution board cage: Loosen and remove the screw securing the cage.
  • Page 36: Cable Routing

    3-16 Cable Routing Suggest Cable Suggest Cable Front switch cable/Front LED cable On board SATA0 #0-#3 cable PDB to Node bridge board power cable PDB signal cable Bottom node bridge board to back plane LAN bridge board cable board slimline SAS cable Top node bridge board back plane board System fan power cable slimline SAS Cable...
  • Page 37: Chapter 4 Motherboard Components

    Chapter 4 Motherboard Components 4-17 Motherboard Components Item Description USB 3.0 ports OCP 2.0 connector #1 PCI Express x8 slot Serial port connector VGA port Gigabit LAN ports IPMB connector SlimLine SAS connector NCSI Switch SATA 6Gb/s connector (suppport SATA DOM) SATA DOM power connector Intel software RAID upgrade key connector Mezzanine slot #1 (x16 bandwidth)
  • Page 38: Jumper Setting

    4-18 Jumper Setting PMBus Address Selec on BIOS_PWD Clear Intel ME Default Password Enable Default Recovery CMOS Clear Default Enable Enable CLR_CMOS ME_RCVR BIOS_PWD BIOS Default Default Force Recovery Update Enable Enable BIOS_RCVR ME_UPDATE Hardware Installation - 38 -...
  • Page 39: Chapter 5 Bios Setup

    Chapter 5 BIOS Setup BIOS (Basic Input and Output System) records hardware parameters of the system in the EFI on the motherboard. Its major functions include conducting the Power-On Self-Test (POST) during system startup, saving system parameters and loading operating system, etc. BIOS includes a BIOS Setup program that allows the user to modify basic system configuration settings or to activate certain system features.
  • Page 40  Main This setup page includes all the items in standard compatible BIOS.  Advanced This setup page includes all the items of AMI BIOS special enhanced features. (ex: Auto detect fan and temperature status, automatically configure hard disk parameters.) ...
  • Page 41: The Main Menu

    The Main Menu Once you enter the BIOS Setup program, the Main Menu (as shown below) appears on the screen. Use arrow keys to move among the items and press <Enter> to accept or enter other sub-menu. Main Menu Help The on-screen description of a highlighted setup option is displayed on the bottom line of the Main Menu.
  • Page 42 Project Name Displays the project name information. Project Version Displays version number of the BIOS setup utility. Build Date and Time Displays the date and time when the BIOS setup utility was created. BMC Information (Note) BMC Firmware Version (Note) Displays BMC firmware version information.
  • Page 43: Advanced Menu

    Advanced Menu The Advanced menu display submenu options for configuring the function of various hardware components. Select a submenu item, then press Enter to access the related submenu screen. - 43 - BIOS Setup...
  • Page 44: Iscsi Configuration

    5-2-1 iSCSI Configuration iSCSI Initiator Name Add an Attempt Press [Enter] for configuration of advanced items. Delete Attempts Press [Enter] for configuration of advanced items. Change Attempt Order Press [Enter] for configuration of advanced items. BIOS Setup - 44 -...
  • Page 45: Intel(R) Virtual Raid On Cpu

    5-2-2 Intel(R) Virtual RAID on CPU Intel(R) Virtual RAID on CPU Press [Enter] to manage Interl® Virtual RAID on the CPU. - 45 - BIOS Setup...
  • Page 46: Trusted Computing

    5-2-3 Trusted Computing Configuration Security Device Support Enable/Disable the TPM support feature. Options available: Enable/Disable. Default setting is Enable. Current Status Information Displays current TPM status information. BIOS Setup - 46 -...
  • Page 47: Serial Port Console Redirection

    5-2-4 Serial Port Console Redirection COM1/COM2 Serial Over LAN Console Redirection (Note) Select whether to enable console redirection for specified device. Console redirection enables the users to manage the system from a remote location. Options available: Enabled/Disabled. Default setting is Disabled. Legacy Console Redirection Selects a COM port for Legacy serial redirection.
  • Page 48: Com1/Com2 Serial Over Lan/Legacy/Serial Port For Out-Of-Band Ems

    5-2-5 COM1/COM2 Serial Over LAN/Legacy/Serial Port for Out-of-Band EMS Console Redirection Settings BIOS Setup - 48 -...
  • Page 49 COM1/COM2 Serial Over LAN Console Redirection Settings Terminal Type Selects a terminal type to be used for console redirection. Options available: VT100/VT100+/ANSI /VT-UTF8. Default setting is ANSI. Bits per second Selects the transfer rate for console redirection. Options available: 9600/19200/38400/57600/115200. Default setting is 115200. Data Bits Selects the number of data bits used for console redirection.
  • Page 50 Parity A parity bit can be sent with the data bits to detect some transmission errors. Even: parity bit is 0 if the num of 1's in the data bits is even. Odd: parity bit is 0 if num of 1's in the data bits is odd. Mark: parity bit is always 1.
  • Page 51: Sio Configuration

    5-2-6 SIO Configuration - 51 - BIOS Setup...
  • Page 52 AMI SIO Driver Version Displays the AMI SIO driver version information. Super IO Chip Logical Device(s) Configuration [*Active*] Serial Port 1/Serial Port 2 Press [Enter] for configuration of advanced items. Serial Port 1/Serial Port 2 Configuration Use This Device When set to Enabled allows you to configure the Serial port 1/Serial port 2 settings. When set to Disabled, displays no configuration for the serial port.
  • Page 53 Options available for Serial Port 2: Use Automatic Settings IO=2F8h; IRQ=3; DMA; IO=3F8h; IRQ=3, 4, 5, 7, 9, 10, 11, 12; DMA; IO=2F8h; IRQ=3, 4, 5, 7, 9, 10, 11, 12; DMA; IO=3E8h; IRQ=3, 4, 5, 7, 9, 10, 11, 12; DMA; IO=2E8h;...
  • Page 54: Pci Subsystem Settings

    5-2-7 PCI Subsystem Settings PCI Bus Driver Version Displays the PCI Bus Driver version information. PCI Express Slot # I/O ROM (Note) When enabled, this setting will initialize the device expansion ROM for the related PCI-E slot. Options available: Enabled/Disabled. Default setting is Enabled. PCI Devices Common Settings Above 4G Decoding Enable/Disable memory mapped I/O to 4GB or greater address space (Above 4G Decoding).
  • Page 55: Network Stack

    5-2-8 Network Stack Network stack Enable/Disable the UEFI network stack. Options available: Enabled/DIsabled. Default setting is Enabled. Ipv4 PXE Support (Note) Enable/Disable the Ipv4 PXE feature. Options available: Enabled/DIsabled. Default setting is Enabled. Ipv4 HTTP Support (Note) Enable/Disable the Ipv4 HTTP feature. Options available: Enabled/DIsabled.
  • Page 56: Csm Configuration

    5-2-9 CSM Configuration Compatibility Support Module Configuration CSM Support (Note) Enable/Disable the Compatibility Support Module (CSM) support. Options available: Enabled/Disabled. Default setting is Disabled. CSM16 Module Version Displays the CSM module version information. Please note that this item is configurable when CSM Support is set to Enabled. Advanced items prompt when this item is set to Enabled. (Note) BIOS Setup - 56 -...
  • Page 57 GateA20 Active When set to Upon Request, GA20 can be disabled using BIOS services. When set to Always, GA20 cannot be disabled; this option is useful when any RT code is executed above 1MB. Options available: Upon Request/Always. Default setting is Upon Request. Please note that this item is configurable when CSM Support is set to Enabled.
  • Page 58: Post Report Configuration

    5-2-10 Post Report Configuration Post Report Configuration Error Message Report Post Error Message Enable/Disable the POST Error Message support. Options available: Enabled/Disabled. Default setting is Enabled. BIOS Setup - 58 -...
  • Page 59: Nvme Configuration

    5-2-11 NVMe Configuration NVMe Configuration Displays the NVMe devices connected to the system. - 59 - BIOS Setup...
  • Page 60: Usb Configuration

    5-2-12 USB Configuration USB Configuration USB Devices: Displays the USB devices connected to the system. XHCI Hand-off Enable/Disable the XHCI (USB 3.0) Hand-off support. Options available: Enabled/Disabled. Default setting is Enabled. USB Mass Storage Driver Support (Note) Enable/Disable the USB Mass Storage Driver Support. Options available: Enabled/Disabled.
  • Page 61: Chipset Configuration

    5-2-13 Chipset Configuration Restore on AC Power Loss (Note) Defines the power state to resume to after a system shutdown that is due to an interruption in AC power. When set to Last State, the system will return to the active power state prior to shutdown. When set to Stay Off, the system remains off after power shutdown.
  • Page 62: Chipset Setup Menu

    Chipset Setup Menu Chipset Setup menu displays submenu options for configuring the function of North Bridge and South Bridge. Select a submenu item, then press Enter to access the related submenu screen. BIOS Setup - 62 -...
  • Page 63: Processor Configuration

    5-3-1 Processor Configuration Processor Configuration Pre-Socket Configuration Press [Enter] for configuration of advanced items. Processor Socket/Processor ID/Processor Frequency/Processor Max Raito/ Processor Min Raio/Microcode Revision/L1 Cache RAM/L2 Cache RAM/L3 Cache RAM/ Processor 0/1 Version Displays the technical specifications for the installed processor. - 63 - BIOS Setup...
  • Page 64 Hyper-Threading [All] The Hyper Threading Technology allows a single processor to execute two or more separate threads concurrently. When hyper-threading is enabled, multi-threaded software applications can execute their threads, thereby improving performance. Options available: Enable/Disable. Default setting is Enable. Enable Intel(R) TXT Enables ord isables the Intel Trusted Execution Technology support function.
  • Page 65 5-3-2 Pre-Socket Configuration - 65 - BIOS Setup...
  • Page 66 CPU Socket 0/1 Configuration Press [Enter] for configuration of advanced items. Core Disable Bitmap(Hex) (for CPU socket 0/1) Number of Cores to enable. 0 means all cores. FFFFFFF means to disable all cores. The maximum value depends on the number of CPUs available. Press the numeric keys to adjust desired values. BIOS Setup - 66 -...
  • Page 67: Common Refcode Configuration

    5-3-3 Common RefCode Configuration Common RefCode Configuration MMIO High Base Selects the MMIO High Base setting. Options available: 56T/40T/24T/16T/4T/1T. Default setting is 56T. MMIO High Granularity Size Selects the allocation size used to assign mmioh resources. Total mmioh space can be up to 32xgranularity. Per stack mmioh resource assignments are multiples of the granularity where 1 unit per stack is the default allocation.
  • Page 68 5-3-4 UPI Configuration BIOS Setup - 68 -...
  • Page 69: Upi Configuration

    UPI General Configuration Press [Enter] to change the UPI general settings. UPI Status Press [Enter] to view the UPI status. Link Frequency Select Selects the UPI link frequency. Options available: 9.6GB/10.4GB/Auto. Default setting is Auto. - 69 - BIOS Setup...
  • Page 70: Memory Configuration

    5-3-5 Memory Configuration Integrated Memory Controller (iMC) Enforce POR When set to Enable, the system enforces Plan Of Record restrictions for DDR4 frequency and voltage programming. When set to Auto, the system sets it to the MRC default settings. Options available: Auto/POR/Disable. Default setting is Enable. Memory Frequency Configures the memory frequency.
  • Page 71: Memory Topology

    Interleave NVDIMMs Controls if NVDIMMs are interleaved together or not. Options available: Enable/Disable. Default setting is Disable. Memory Topology Press [Enter] for configuration of advanced items. Memory RAS Configuration Press [Enter] for configuration of advanced items. - 71 - BIOS Setup...
  • Page 72 5-3-6 Memory Topology BIOS Setup - 72 -...
  • Page 73: Memory Ras Configuration

    5-3-7 Memory RAS Configuration Memory RAS Configuration Setup RAS Type Displays the RAS type. Static Virtual Lockstep Mode Enable/Disable the Static Virtual Lockstep mode. Options available: Disable/Enable. Default setting is Disable. Mirror Mode Mirror Mode will set entire 1LM/2LM memory in system to be mirrored, consequently reducing the memory capacity by half.
  • Page 74: Iio Configuration

    5-3-8 IIO Configuration IIO Configuration Intel® VT for Directed I/O (VT-d) Press [Enter] for configuration of advanced items. Inter® VMD technology Press [Enter] for configuration of advanced items. BIOS Setup - 74 -...
  • Page 75: Intel® Vt For Directed I/O (Vt-D)

    5-3-9 Intel® VT for Directed I/O (VT-d) Intel® VT for Directed I/O (VT-d) Intel® VT for Directed I/O (VT-d) Enable/Disable the Intel VT for Directed I/O (VT-d) support function by reporting the I/O device assignment to VMM through DMAR ACPI Tables. Options available: Enable/Disable.
  • Page 76: Inter® Vmd Technology

    5-3-10 Inter® VMD Technology Intel® VMD technology Intel® VMD Configuration Enable/Disable the Intel VMD support function. Options available: Enable/Disable. Default setting is Disable. BIOS Setup - 76 -...
  • Page 77: Advanced Power Management Configuration

    5-3-11 Advanced Power Management Configuration Advanced Power Management Configuration CPU P State Control Press [Enter] for configuration of advanced items. Hardware PM State Control Press [Enter] to configure the Hardware P-State setting. CPU C State Control Press [Enter] for configuration of advanced items. Package C State Control Press [Enter] to configure the Package C State limit.
  • Page 78: Cpu P State Control

    5-3-12 CPU P State Control SpeedStep (Pstates) Conventional Intel SpeedStep Technology switches both voltage and frequency in tandem between high and low levels in response to processor load. Options available: Enable/Disable. Default setting is Enable. Turbo Mode When this item is enabled, the processor will automatically ramp up the clock speed of 1-2 of its processing cores to improve its performance.
  • Page 79: Hardware Pm State Control

    5-3-13 Hardware PM State Control Hardware P-States When this item is disabled, the processor hardware chooses a P-state based on OS Request (Legacy P-States). In Native mode, the processor hardware chooses a P-state based on OS guidance. In Out of Band mode, the processor hardware autonomously chooses a P-state (with no OS guidance). Options available: Disable/Native Mode/Out of Band Mode/Native Mode with No Legacy Support.
  • Page 80: Cpu C State Control

    5-3-14 CPU C State Control Autonomous Core C-State Enable/Disable the Autonomous Core C-State Control. Options available: Enable/Disable. Default setting is Disable. CPU C6 Report Allows you to determine whether to let the CPU enter C6 mode in system halt state. When enabled, the CPU core frequency and voltage will be reduced during system halt state to decrease power consumption.
  • Page 81: Package C State Control

    5-3-15 Package C State Control Package C-State Configures the state for the C-State package limit. Options available: C0/C1 state/C2 state/C6(non Retention) state/C6(Retention) state/No Limit/Auto. Default setting is Auto. - 81 - BIOS Setup...
  • Page 82: Cpu-Advanced Pm Tuning

    5-3-16 CPU-Advanced PM Tuning Energy Perf BIAS Enters the Energy Perf BIAS submenu. Power Performance Tuning (Note) Tunes the Power Performance Configuration mode. When enabled, uses IA32_ENERGY_PERF_BIAS input from the core. When disabled, uses alternate performance BIAS input from ENERGY_PERF_ BIAS_CONFIG.
  • Page 83 ENERGY_PERF_BIAS_CFG mode Selects the Energy Performance Bias Configuration Mode. Options available: Performance/Balanced Performance/Balanced Power/Power. Default setting is Balanced Performance. Please note that this item is configurable when Power Performance Tuning is set to BIOS Con- trols EPB. - 83 - BIOS Setup...
  • Page 84: Pch Configuration

    5-3-17 PCH Configuration PCH Configuration PCH SATA Configuration Press [Enter] for configuration of advanced items. PCH sSATA Configuration Press [Enter] for configuration of advanced items. BIOS Setup - 84 -...
  • Page 85: Pch Sata Configuration

    5-3-18 PCH SATA Configuration PCH SATA Configuration SATA Controller(s) Enable/Disable SATA controller. Options available: Enable/Disable. Default setting is Enable. Configure SATA as Configure on chip SATA type. AHCI Mode: When set to AHCI, the SATA controller enables its AHCI functionality. Then the RAID function is disabled and cannot be access the RAID setup utility at boot time. - 85 - BIOS Setup...
  • Page 86 RAID Mode: When set to RAID, the SATA controller enables both its RAID and AHCI functions. You will be allows access the RAID setup utility at boot time. Options available: AHCI/RAID. Default setting is AHCI. Alternate Device ID on RAID (Note 1) Enable/Disable Alternate Device ID on RAID mode.
  • Page 87: Pch Ssata Configuration

    5-3-19 PCH sSATA Configuration PCH sSATA Configuration sSATA Controller(s) Enable/Disable sSATA controller. Options available: Enable/Disable. Default setting is Enable. Configure sSATA as Configure on chip SATA type. AHCI Mode: When set to AHCI, the SATA controller enables its AHCI functionality. Then the RAID function is disabled and cannot be access the RAID setup utility at boot time. - 87 - BIOS Setup...
  • Page 88 RAID Mode: When set to RAID, the SATA controller enables both its RAID and AHCI functions. You will be allows access the RAID setup utility at boot time. Options available: AHCI/RAID. Default setting is AHCI. Alternate Device ID on RAID (Note 1) Enable/Disable Alternate Device ID on RAID mode.
  • Page 89: Miscellaneous Configuration

    5-3-20 Miscellaneous Configuration Miscellaneous Configuration Active Video Selects the active video type. Options available: Auto/Onboard Device/PCIE Device. Default setting is Auto. - 89 - BIOS Setup...
  • Page 90: Server Me Configuration

    5-3-21 Server ME Configuration General ME Configuration Operational Firmware Version Displays Operational Firmware version information. ME Firmware Status #1/#2 Displays ME Firmware status information. Current State (for ME Firmware) Displays ME Firmware current status information. Error Code (for ME Firmware) Displays ME Firmware status error code. Recovery Cause (for ME Firmware) Displays ME Firmware recovery cause.
  • Page 91: Runtime Error Logging

    5-3-22 Runtime Error Logging Runtime Error Logging System Errors Enable/Disable system error logging function. Options available: Enable/Disable. Default setting is Enable. S/W Error Injection Support Enable/Disable software injection error logging function. Options available: Enable/Disable. Default setting is Disable. Whea Settings Press [Enter] for configuration of advanced items.
  • Page 92: Whea Settings

    5-3-23 Whea Settings WHEA Support (Windows Hardware Error Architecture) Enable/Disable WHEA Support. Options available: Enable/Disable. Default setting is Enable. BIOS Setup - 92 -...
  • Page 93: Memory Error Enabling

    5-3-24 Memory Error Enabling Memory Error Enable/Disable Memory Error. Options available: Enable/Disable. Default setting is Enable. Memory Corrected Error Enable/Disable Memory Corrected Error. Options available: Enable/Disable. Default setting is Enable. Uncorrected Error disable Memory Enable/Disable the Memory that triggers Uncorrected Error. Options available: Enable/Disable.
  • Page 94: Pcie Error Enabling

    5-3-25 PCIe Error Enabling Corrected Error Enables and escalates Correctable Errors to error pins. Options available: Enable/Disable. Default setting is Enable. Uncorrected Error Enables and escalates Uncorrectable/Recoverable Errors to error pins. Options available: Enable/Disable. Default setting is Enable. Fatal Error Enable Enables and escalates Fatal Errors to error pins.
  • Page 95: Server Management Menu

    Server Management Menu FRB-2 Timer Enable/Disable FRB-2 timer (POST timer). Options available: Enabled/Disabled. Default setting is Disabled. FRB-2 Timer timeout Configure the FRB2 Timer timeout. Options available: 3 minutes/4 minutes/5 minutes/6 minutes. Default setting is 6 minutes. Please note that this item is configurable when FRB-2 Timer is set to Enabled. FRB-2 Timer Policy Configure the FRB2 Timer policy.
  • Page 96 System Event Log Press [Enter] for configuration of advanced items. View FRU Information Press [Enter] to view the advanced items. BMC network configuration Press [Enter] for configuration of advanced items. IPv6 BMC Network Configuration Press [Enter] for configuration of advanced items. BIOS Setup - 96 -...
  • Page 97: System Event Log

    5-4-1 System Event Log Enabling/Disabling Options SEL Components Change this item to enable or disable all features of System Event Logging during boot. Options available: Enabled/Disabled. Default setting is Enabled. Erasing Settings Erasing SEL Choose options for erasing SEL. Options available: No/Yes, On next reset/Yes, On every reset. Default setting is No. When SEL is Full Choose options for reactions to a full SEL.
  • Page 98: View Fru Information

    5-4-2 View FRU Information The FRU page is a simple display page for basic system ID information, as well as System product information. Items on this window are non-configurable. (Note) The model name will vary depends on the product you purchased BIOS Setup - 98 -...
  • Page 99: Bmc Network Configuration

    5-4-3 BMC Network Configuration Select NCSI and Dedicated LAN Switch NCSI and dedicated LAN and send KCS command. Options available: Do Nothing/Mode1 (Dedicated)/Mode2(NSCI)/Mode3 (Failover). Default setting is Mode1 (Dedicated). Lan Channel 1 Configuration Address source Select to configure LAN channel parameters statically or dynamically (DHCP). Do nothing option will not modify any BMC network parameters during BIOS phase.
  • Page 100: Ipv6 Bmc Network Configuration

    5-4-4 IPv6 BMC Network Configuration IPv6 BMC Lan Channel 1 IPv6 BMC Lan Option Enable/Disable IPv6 BMC LAN channel function. When this item is disabled, the system will not modify any BMC network during BIOS phase. Options available: Enable/Disable. Default setting is Enable. IPv6 BMC Lan IP Address Source Select to configure LAN channel parameters statically or dynamically (by BIOS or BMC).
  • Page 101: Security Menu

    Security Menu The Security menu allows you to safeguard and protect the system from unauthorized use by setting up access passwords. There are two types of passwords that you can set: • Administrator Password Entering this password will allow the user to access and change all settings in the Setup Utility. •...
  • Page 102: Secure Boot

    5-5-1 Secure Boot The Secure Boot submenu is applicable when your device is installed the Windows 8 (or above) operating ® system. System Mode Displays the system is in User mode or Setup mode. Secure Boot Displays the Secure Boot function is actived or not actived. Vendor Keys Displays the Vendor Keys function is actived or not actived.
  • Page 103: Key Management

    5-5-2 Key Management Provision Factory Defaults Allows to provision factory default Secure Boot keys when system is in Setup Mode. Options available: Enabled/Disabled. Default setting is Disabled. Install Factory Default Keys Installs all factory default keys. It will force the system in User Mode. Options available: Yes/No.
  • Page 104 Forbidden Signatures (DBX) Displays the current status of the Forbidden Signature Database. Press [Enter] to configure a new dbx or load additional dbx from storage devices. Options available: Set New/Append. Authorized TimeStamps (DBT) Displays the current status of the Authorized TimeStamps Database. Press [Enter] to configure a new DBT or load additional DBT from storage devices.
  • Page 105: Boot Menu

    Boot Menu The Boot menu allows you to set the drive priority during system boot-up. BIOS setup will display an error message if the legacy drive(s) specified is not bootable. Boot Configuration Setup Prompt Timeout Number of seconds to wait for setup activation key. 65535 (0xFFFF) means indefinite waiting. Press the numeric keys to input the desired values.
  • Page 106: 1Uefi Application Boot Priorities

    UEFI Network Drive BBS Priorities Press [Enter] to configure the boot priority. UEFI Application Boot Priorities Press [Enter] to configure the boot priority. BIOS Setup - 106 -...
  • Page 107: Uefi Network Drive Bbs Priorities

    5-6-1 UEFI NETWORK Drive BBS Priorities The UEFI network drive BBS priorities submenu allows you to specify the boot device priority from the available UEFI network drives during system boot-up. BIOS setup will display an error message if the legacy drive(s) specified is not bootable.
  • Page 108 5-6-2 1UEFI Application Boot Priorities The UEFI application boot priorities submenu allows you to specify the boot device priority from the available UEFI applications during system boot-up. BIOS setup will display an error message if the legacy drive(s) specified is not bootable. BIOS Setup - 108 -...
  • Page 109: Save & Exit Menu

    Save & Exit Menu The Exit menu displays the various options to quit from the BIOS setup. Highlight any of the exit options then press Enter. Save Options Save Changes and Exit Saves changes made and closes the BIOS setup. Options available: Yes/No.
  • Page 110 Default Options Restore Defaults Loads the default settings for all BIOS setup parameters. Setup Defaults are quite demanding in terms of resources consumption. If you are using low-speed memory chips or other kinds of low-performance components and you choose to load these settings, the system might not function properly. Options available: Yes/No.
  • Page 111: Bios Post Codes

    BIOS POST Codes 5-8-1 AMI Standard - PEI PEI_CORE_STARTED 0x10 PEI_CAR_CPU_INIT 0x11 PEI_CAR_NB_INIT 0x15 PEI_CAR_SB_INIT 0x19 PEI_MEMORY_SPD_READ 0x2B PEI_MEMORY_PRESENCE_DETECT 0x2C PEI_MEMORY_TIMING 0x2D PEI_MEMORY_CONFIGURING 0x2E PEI_MEMORY_INIT 0x2F PEI_MEMORY_INSTALLED 0x31 PEI_CPU_INIT 0x32 PEI_CPU_CACHE_INIT 0x33 PEI_CPU_AP_INIT 0x34 PEI_CPU_BSP_SELECT 0x35 PEI_CPU_SMM_INIT 0x36 PEI_MEM_NB_INIT 0x37 PEI_MEM_SB_INIT 0x3B PEI_DXE_IPL_STARTED...
  • Page 112 DXE_SB_INIT 0x70 DXE_SB_SMM_INIT 0x71 DXE_SB_DEVICES_INIT 0x72 DXE_ACPI_INIT 0x78 DXE_CSM_INIT 0x79 DXE_BDS_STARTED 0x90 DXE_BDS_CONNECT_DRIVERS 0x91 DXE_PCI_BUS_BEGIN 0x92 DXE_PCI_BUS_HPC_INIT 0x93 DXE_PCI_BUS_ENUM 0x94 DXE_PCI_BUS_REQUEST_RESOURCES 0x95 DXE_PCI_BUS_ASSIGN_RESOURCES 0x96 DXE_CON_OUT_CONNECT 0x97 DXE_CON_IN_CONNECT 0x98 DXE_SIO_INIT 0x99 DXE_USB_BEGIN 0x9A DXE_USB_RESET 0x9B DXE_USB_DETECT 0x9C DXE_USB_ENABLE 0x9D DXE_IDE_BEGIN 0xA0 DXE_IDE_RESET 0xA1 DXE_IDE_DETECT...
  • Page 113: Ami Standard - Error

    5-8-3 AMI Standard - ERROR PEI_MEMORY_INVALID_TYPE 0x50 PEI_MEMORY_INVALID_SPEED 0x50 PEI_MEMORY_SPD_FAIL 0x51 PEI_MEMORY_INVALID_SIZE 0x52 PEI_MEMORY_MISMATCH 0x52 PEI_MEMORY_NOT_DETECTED 0x53 PEI_MEMORY_NONE_USEFUL 0x53 PEI_MEMORY_ERROR 0x54 PEI_MEMORY_NOT_INSTALLED 0x55 PEI_CPU_INVALID_TYPE 0x56 PEI_CPU_INVALID_SPEED 0x56 PEI_CPU_MISMATCH 0x57 PEI_CPU_SELF_TEST_FAILED 0x58 PEI_CPU_CACHE_ERROR 0x58 PEI_CPU_MICROCODE_UPDATE_FAILED 0x59 PEI_CPU_NO_MICROCODE 0x59 PEI_CPU_INTERNAL_ERROR 0x5A PEI_CPU_ERROR 0x5A PEI_RESET_NOT_AVAILABLE 0x5B...
  • Page 114: Intel Upi Post Codes

    5-8-4 Intel UPI POST Codes Initialize KTIRC inuput structure default values 0xA0 Collect info such as SBSP, Boot Mode, Reset type etc 0xA1 Setup IO SADs in SBSP to access the config space 0xA2 Setup up minimum path between SBSP & other sockets 0xA3 Add the node to the tree Parse the LEP of the discovered socket...
  • Page 115: Intel Mrc Post Codes

    Unsupported topology 0xDC RC Behavior: System Halt SBSP cannot find KPIRC TXEQ Parameters for this 0xDD link in GetSocketLinkEparams(). No retry. RC Behavior: System Halt 5-8-6 Intel MRC POST Codes Detect DIMM population 0xB0 Set DDR frequency 0xB1 Gather remaining SPD data 0xB2 Program registers on the memory controller level 0xB3...
  • Page 116: Intel Pm Post Codes

    5-8-8 Intel PM POST Codes Start of PPM structure initialization 0xD0 PPM CSR programming 0xD1 PPM MSR programming 0xD2 Start of PState transition init 0xD3 PPM exit 0xD4 PPM On ready to boot event 0xD5 5-8-9 Intel PM POST Codes Start of IIO early Initialization 0xE0 Pre Link training...
  • Page 117: Bios Post Beep Code (Ami Standard)

    BIOS POST Beep code (AMI standard) 5-9-1 PEI Beep Codes # of Beeps Description Memory not Installed. Memory was installed twice (InstallPeiMemory routine in PEI Core called twice) Recovery started DXEIPL was not found DXE Core Firmware Volume was not found Recovery failed S3 Resume failed Reset PPI is not available...
  • Page 118: Bios Recovery Instruction

    5-10 BIOS Recovery Instruction The system has an embedded recovery technique. In the event that the BIOS becomes corrupt the boot block can be used to restore the BIOS to a working state. To restore your BIOS, please follow the instructions listed below: Recovery Instruction: Change xxx.ROM to amiboot.rom.

Table of Contents