Napoleon Altitude AX36NTE Installation Manual page 5

Hide thumbs Also See for Altitude AX36NTE:
Table of Contents

Advertisement

Available languages

Available languages

Installer: please fi ll out appliance checklist
When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specifi c recommendations
from the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of 4% for each
additional 1,000ft (305m). Expansion / contraction noises during heating up and cooling down cycles are normal
and are to be expected. Change in fl ame appearance from "HI" to "LO" is more evident in natural gas than in
propane.
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is certifi ed for mobile
home installation.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certifi ed kit is used.
note:
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the
appliance and must be installed.
The protective wrap on plated parts is best removed when the assembly is at room temperature but this can be
improved if the assembly is warmed, using a hair dryer or similar heat source.
This appliance is a decorative product. It is not a source of heat and not intended to burn solid fuel.
Batteries must be disposed of according to the local laws and regulations. Some batteries may be
recycled, and may be accepted for disposal at your local recycling center. Check with your
municipality for recycling instructions.
1.1
rates and specifi cations
Fuel Type
Altitude (FT)
Max. Input (BTU/hr)
Min. Inlet Gas Supply Pressure
Max. Inlet Gas Supply Pressure
Manifold Pressure (Under Flow
Confi ctions)
*Maximum inlet pressure not to exceed 13".
This appliance is suitable for use with Napoleon's optional Altitude™ X Heat Management system. THIS
MANUAL DOES NOT include detailed information relating the optional ssytem. Framing and fi nishing are NOT
the same. For further details, refer to AXHM instructions provided with the kit before starting installation.
in the Owner's manual.
AX36
Natural Gas
36,500
4.5" w.c. (11mb)
7"* w.c. (17mb)
3.5" w.c. (9mb)
1.0 general information
general information
Propane
Natural Gas
0-4,500
35,000
38,000
11" w.c. (27mb)
4.5" w.c. (11mb)
13" w.c. (32mb)
7"* w.c. (17mb)
10" w.c. (25mb)
3.5" w.c. (9mb)
EN
AX42
Propane
36,500
11" w.c. (27mb)
13" w.c. (32mb)
10" w.c. (25mb)
5
W415-1935 / D / 07.08.20