Installing Non-Combustible Board - Napoleon Altitude AX36NTE Installation Manual

Hide thumbs Also See for Altitude AX36NTE:
Table of Contents

Advertisement

Available languages

Available languages

fi nishing
EN
9.5

installing non-combustible board

WARNING
!
Non-combustible facing material must not project more than 4" (101.6mm) from the face of the door (all four
sides). If greater projections are desired, increase the clearance to the sides, bottom and top by 2" (50.8mm) for
every additional 1" (25.4mm) of projection. If using an optional surround, the same rule applies, starting from the
top of the surround. Ensure clearances are maintained for surround removal, as it must lift off the appliance for
maintenance.
1. Align the non-combustible panel against the appliance.
2. Mark the non-combustible panel to pre-drill holes.
3. Secure the non-combustible panel to the appliance.
note:
Do not notch the framing around the appliance
standoffs. Failure to maintain air clearance space
could cause overheating and/or fi re.
35 1/4" (89.5cm)
WIDTH
12"
(30.5cm)
Joint Compound where required
Joint compounds such as Durabond 90 and tapes that are resilient to heat and cracking should be used when
taping and mudding seams.
Setting tiles and grouting
We recommend you use tiles with a dry butt joint to be installed using a two-part mortar with an acrylic latex
additive, such as Mapei Kerabond/Kerlastic, to allow for slight movement in the normal operation of the appliance.
If grout is used between the tiles, a polymer-based grout, such as Mapei Ultracolour plus, is recommended.
Primer/Paint
For a painted surface, use a 100% acrylic latex primer and fi nish coat. Light coloured paints may discolour.
note:
Non-combustible panel shipped loose in carton.
40
W415-1935 / D / 07.08.20
AX36
AX42
42 1/4" (107.3cm)

Advertisement

Table of Contents
loading

Table of Contents