The coffee dose can be adjusted by means of potentiometer R26 on the electronic card (must only be
performed by a Service Centre).
Potentiometer R26 varies the input voltage to the microprocessor from 0 to 5 V.
The following table provides comparisons for dose adjustments:
Voltage (V)
0
1
2
3
4
5
Il grinding time on average 1.3 – 1.5 g /sec.
Factory settings are 100 pulses, equal to a dose of approx. 8.5 g
Turn potentiometer R26 anticlockwise to increase the dose of ground coffee (=122 pulses).
Turn potentiometer R26 clockwise to decrease the dose of ground coffee (=80 pulses).
*
The dose varies according to the coffee blend used.
EN Incanto DOT.indd

Ground coffee dose adjustment

Coffee grinder pulses
106
114
122
29
80
92
97
18/05/2005, 12.05
*
Coffee dose (g)
6,8
7,5
8,2
8,9
9,6
10,3
29