9. Run pump until cleaning ball exits material hose.
Save cleaning ball (Base Coat Only).
ti4551c
10. Turn on/off switch OFF and turn prime/drain valve to
DRAIN. Clean outside of pump and suction tube
with brush and water.
ti10796b
11. Connect applicator to material hose. Close
prime/drain valve.
12. Turn on/off switch ON.
Base Coat Pump: Turn prime switch ON, or appli-
cator switch on material hose.
13. Run pump until clean water flows from applicator.
ti13641a
313888F
ti14632a
ti21038a
ti10795b
ti21039a
14. Add additional water and repeat steps 12 - 13 if nec-
essary.
ti13839a
15. Open prime/drain valve and turn prime switch ON to
flush valve.
16. Turn on/off switch OFF when valve is thoroughly
flushed.
17. Open over pressure relief valve and turn prime
switch ON to flush valve.
ti14632a
ti10796b