7. Turn air valve on and adjust air valve and/or select
alternative nozzles or spray discs to achieve desired
pattern.
ti21034a
8. Spray test pattern. Move applicator to spray sur-
face. NOTE: See Air Spray Trigger Gun manual for
helpful hints on spray patterns.
Keep gun triggered as much as possible to
prevent pack-out.
If gun has not been triggered for longer than 3
minutes, perform Pressure Relief (page 10) in
the pump and hose to prevent packout.
Turn off applicator switch on hose before detrig-
gering to minimize retained pressure.
Make sure air is flowing before triggering gun.

Spray Gun (Top Coat Pump)

1. Lock gun trigger safety. Insert seat and OneSeal
Insert SwitchTip.
ti13131a
313888F
1/8 in.
1/4 in.
3/8 in.
5/16 in.
NOTICE
Seat
SwitchTip
ti5800a
One seal
2. Screw assembly onto gun. Hand tighten.
3. Trigger gun and spray test pattern. Slowly adjust
pressure to eliminate heavy edges. Use smaller tip
size if pressure adjustment can not eliminate heavy
edges.
heavy
edges
4. Hold gun perpendicular, 10-12 in. (25-30 cm) from
surface. Spray back and forth. Use strokes over-
lapped by 50%. Start gun movement before trigger-
ing gun and release trigger before stopping gun
movement.
.
ti5801a
ti5823a
ti5824a