Flue Options; Flue Lengths - Bosch WORCESTER GREENSTAR Ri ErP Series Installation, Commissioning And Servicing Instructions

Wall hung rsf gas fired condensing boiler
Table of Contents

Advertisement

4.8

FLUE OPTIONS

WARNING: Flue systems
▶ Only use Worcester, Bosch approved flue systems, no
other manufacturer's flue systems have been
approved for use with Worcester appliances.
CAUTION: Non accessible flue systems:
▶ Where a flue system is not going to be accessible,
provision must be made for service and inspection.
▶ Voids containing concealed flues must have at least
one inspection hatch no less than 300mm square.
▶ Flue joints within the void must not be more than 1.5
metres from the edge of the inspection hatch.
▶ Inspection hatches should be located at changes of
direction.
▶ If this is not possible, bends should be viewable from
both directions.
NOTICE: Effective flue lengths:
▶ each 90° bend is equivalent to 2 metres of straight flue
▶ each 45° bend is equivalent to 1 metre of straight flue
Plume management kits are available for the 60/100
horizontal flue system.
Refer to the manual supplied with the plume
management kits for complete installation instructions
Part number
Flue
7 716 191 082
60/100 Telescopic horizontal flue assembly
7 716 191 171
60/100 Longer telescopic horizontal flue
7 733 600 048
60/100 Horizontal high level telescopic flue
7 719 003 702
80/125 Telescopic horizontal flue assembly
7 719 002 430
60/100 Vertical flue assembly
7 719 002 431
80/125 Vertical flue assembly
Table 17 Flue kit part numbers
4.8.1

Flue lengths

The flue systems have different maximum flue lengths
The Greenstar series has the option of two horizontal 60/100 RSF
(telescopic and longer telescopic) and one horizontal 80/125 RSF
(telescopic) flue system and two vertical RSF (60/100 or 80/125) flue
systems:
Refer to the following example Flue options for the maximum flue
lengths.
Horizontal high level flue assembly
Horizontal high level telescopic flue assembly 202 - 603 N/A
Table 18
Greenstar Ri
ErP
- 6 720 813 283 (2016/07)
Description
assembly
kit
60/100 mm
383 mm - 603 mm
130 mm Min
Flue length (mm)
60/100
80/125
TELESCOPIC HORIZONTAL FLUE ASSEMBLY
Telescopic horizontal flue assembly
Longer telescopic horizontal flue assembly 570 - 790
Table 19
Extended horizontal flue
Extended horizontal flue
Table 20
Horizontal flue with additional elbow (1 x 90 ° bend)
Horizontal flue with 1 x 90° bend
Table 21
Horizontal flue with additional elbows (2 x 90 ° bends)
Horizontal flue with 2 x 90° bends
Table 22
PRE-INSTALLATION
60/100 mm
350 mm - 570 mm
130 mm Min
Flue length (mm)
60/100
80/125
180 - 570
405 - 600
N/A
Maximum flue length
(mm)
60/100
80/125
4,600
13,000
Maximum flue length
(mm)
60/100
80/125
2,600
11,000
Maximum flue length
(mm)
60/100
80/125
N/A
9,000