Flue Options - Bosch Worcester Greenstar CDi Classic System ErP Series Installation, Commissioning And Servicing Instructions

Wall hung rsf gas fired condensing system boiler
Table of Contents

Advertisement

3.9

Flue options

The Greenstar CDi Classic System
RSF (60/100 telescopic, 60/100 longer telescopic and 80/125
telescopic) flue systems and two vertical RSF (60/100 or 80/125)
regular flue systems:
The systems have different maximum flue lengths for different boiler
outputs and different plume management lengths.
For every extra 1000mm of plume management after the first 500mm,
the internal 60/100 flue length must be reduced by 700mm, up to a
maximum of 4500mm of plume management.
For example on a 30CDi Classic System
effective length was 1500mm, the inner flue would be reduced to
5200mm.
Maximum horizontal flue lengths (L)
Boiler model 100mmØ
No Plume
+ 500mm
management
of plume
management
30CDi
7,900mm
5,900mm
35CDi
7,000mm
5,000mm
Table 15 Maximum horizontal flue lengths
Maximum vertical flue lengths
Boiler model
100mmØ
30CDi
9,400mm
35CDi
8,000mm
Table 16 Maximum vertical flue lengths
This page and the page opposite shows various flue options with the
straight flue lengths required to achieve the maximum flue length.
NOTICE: 60/100 Flue systems:
▶ Each 90° bend used is equivalent to 1.5 metres of
straight flue.
▶ Each 45° bend used is equivalent to 0.75 metres of
straight flue.
NOTICE: 80/125 flue systems:
▶ Each 90° bend used is equivalent to 2 metres of
straight flue.
▶ Each 45° bend used is equivalent to 1 metre of
straight flue.
Telescopic horizontal flue
Flue option 1
100mmØ
30CDi
570mm
35CDi
570mm
Table 17 Option 1
Horizontal extended flue
Flue option 2
100mmØ
30CDi
7,900mm
35CDi
7,000mm
Table 18 Option 2
6 720 815 724 (2015/11)
ErP
has the option of three horizontal
ErP
if the plume management
125mmØ
+4500mm
No plume
of plume
management
management
available
3,100mm
18,500mm
2,200mm
16,000mm
125mmØ
18,500mm
16,000mm
125mmØ
600mm
600mm
125mmØ
18,500mm
16,000mm
Horizontal extended flue with 1x90° bends
Flue option 3
100mmØ
30CDi
6,400mm
35CDi
5,500mm
Table 19 Option 3
Horizontal extended flue with 2x90° bends
Flue option 4
100mmØ
30CDi
4,900mm
35CDi
4,000mm
Table 20 Option 4
High level horizontal extended flue
Flue option 5
100mmØ
30CDi
7,900mm
35CDi
7,000mm
Table 21 Option 5
High level horiz. extended flue with 2x90° bends
Flue option 6
100mmØ
30CDi
6,400mm
35CDi
5,500mm
Table 22 Option 6
High level horiz. extended flue with 3x90° bends
Flue option 7
100mmØ
30CDi
4,900mm
35CDi
4,000mm
Table 23 Option 7
Vertical balanced extended flue assembly
Flue option 8
100mmØ
30CDi
9,400mm
35CDi
8,000mm
Table 24 Option 8
Vertical balanced extended flue with 2x90° bends
Flue option 9
100mmØ
30CDi
6,400mm
35CDi
5,000mm
Table 25 Option 9
Vertical balanced extended flue with 2x45° bends
Flue option 10
100mmØ
30CDi
7,900mm
35CDi
6,500mm
Table 26 Option 10
PRE-INSTALLATION
125mmØ
16,500mm
14,000mm
125mmØ
14,500mm
12,000mm
125mmØ
18,500mm
16,000mm
125mmØ
16,500mm
14,000mm
125mmØ
14,500mm
12,000mm
125mmØ
18,500mm
16,000mm
125mmØ
14,500mm
12,000mm
125mmØ
16,500mm
14,000mm
17

Advertisement

Table of Contents
loading

Table of Contents