F.
The condenser fan may cycle off during the harvest cycle – this would be normal.
NOTE:
Installing an IMI Cornelius remote cuber with other than an IMI Cornelius remote condenser
and line set may be reason to void the cuber warranty.
4. Each condenser and cuber is connected with two (2) *pre-charged lines.
A.
The pre-charged lines are ordered separately from the condenser to suit each individual application.
B.
The pre-charged line lengths are 20 feet [6.096 meters], 35 feet [10.66 meters] and 55 feet [16.76 me-
ters].
NOTE
(Pre-charged is defined as a vapor holding charge – not a portion of the system charge.)
5. Installation of line kits (see drawing). Remove the tubing from the carton. Carefully uncoil the lines so the
tubing doesn't become kinked, and route lines to cuber and condenser.
6. Keep line-set as short as possible. Place a 3-foot service loop behind cuber to allow for rear service
should it ever be required.