MODEL
IAC630
UNIT
Volts
230
Phase
1
Hertz
60
No. Wires
2+ground
MIN. CIRCUIT
Amps
20
MAX FUSE SIZE (HVAC CIRCUIT BREAKER REQUIRED)
Amps
20
REFRIGERANT
Type
R404A(HP62)
Weight (oz)
43
Weight (g)
1219
COMPRESSOR
Volts
230
Phase
1
Hertz
60
LRA
69
RLA
8.8
CONDENSER FAN MOTOR (Air-Cooled Systems only) or
AIR CIRCULATION FAN MOTOR (Water-Cooled and Remote Systems only)
Volts
230
Phase
1
Hertz
60
Amps Running
1.09
Watts
75
WATER PUMP
Volts
230
Phase
1
Hertz
60
Amps Running
0.5
HP
1/30
SPECIFICATIONS – 60 HZ
ICE CUBER SPECIFICATION
IWC630
IRC630
230
230
1
1
60
60
2+ground
2+ground
20
20
20
20
R404A(HP62)
R404A(HP62)
35
170
992
4820
230
230
1
1
60
60
69
69
8.8
8.8
230
230
1
1
60
60
0.36
0.36
6
6
230
230
1
1
60
60
0.5
0.5
1/30
1/30
IAC830
IWC830
230
230
1
1
60
60
2+ground
2+ground
20
20
20
20
R404A(HP62)
R404A(HP62)
55
33
1559
936
230
230
1
1
60
60
61
61
12.5
12.5
230
230
1
1
60
60
1.09
0.36
75
6
230
230
1
1
60
60
0.5
0.5
1/30
1/30
IRC830
230
1
60
2+ground
20
20
R404A(HP62)
170
4820
230
1
60
61
12.5
230
1
60
0.36
6
230
1
60
0.5
1/30

Hide quick links: