Slow Production (Cube Formation Good) - Cornelius CCM0330 Service And Maintenance Manual

Nordic ice maker model ccm and ccu series
Table of Contents

Advertisement

Slow Production (Cube Formation Good)

Does
installation
meet
guidelines?
NO
Correct any
installation
defects
YES
Check for excessive
head pressure
TOO HIGH
Is this unit air
cooled or
water cooled?
WATER
Check Water
Regulating Valve,
See page E2
OK
See Condenser
service information
page E2
AIR
Is the Air
Condenser
clean?
Clean
Condenser and
Condenser Fan
Blade
NOT OK
Page C6
Troubleshooting Trees
OK
Check refrigeration
system, Section E
YES
Check refrigeration
system, Section E
NO
Adjust or
replace Water
Regulating
Valve