Machine Does Not Run

Is the selector
switch set to
ICE?
NO
Set selector
Switch to the
ICE position
YES
Check for correct
power supply to the
machine
Check High
Pressure Safety
Check High
Temperature Safety
Check Bin Control
for proper
adjustment, see
page F9
Is this a Remote
Is the Liquid line
Solenoid energized
and open?
NOT OK
OK
TRIPPED
Control
OK
OPEN
Control
OK
BAD
GOOD
NO
unit?
OK
Page C3
Troubleshooting Trees
Correct field
wiring deficiency
Reset and
identify reason
for high head
pressure
Replace or
identify reason
for being open.
Adjust as
required or
replace if
defective
Selector Switch
could be
defective, see
page F1
OK
NOT OK
Find reason for
non-activity or
replace if
defective