en | Appendices
May walk test automatic points
May walk test points
Tab. 8.5: Permissions
See also
8.2.11

Additional functions of the main panel

The panel has the following additional functions which do not have any influence on the
intended operation of the panel.
Point type technical, fire for alarm inputs
Inputs that are assigned the device Point can be programmed to the point type technical or
fire (refer to Point types and point evaluation, page 59).
Internal program
Points of the point type Intrusion can be assigned to an internal program.
When points are assigned to an internal program, and internal program is switched on, the
points are capable of alarm signaling in disarmed state.
If the detector is tripped, an internal alarm is generated.
This internal alarm results in only local alarm signaling without a remote alarm.
Outputs for individual applications
Outputs of the panel can be used to control individual applications. A prerequisite for this is
that no behavior item (no activation by the intended operation of the panel) is assigned to
such an output.
Manual output control
4
Automatic via schedule
1.
2.
3.
Chime mode
If Chime Mode is activated on the control center in disarmed state, tripping of an intrusion
point with the option Chime Mode Capable leads to a one-off chime tone on the control
center.
4
8.3

Requirements in accordance with SES

The basis for this requirement is the standard EN 50131 grade 3 (refer to Requirements in
accordance with EN 50131 grade 3, page 74). Deviations from this standard are already taken
into account in the fundamental behavior of the panel and / or described below.
8.3.1

Selecting the default setting

1.
2.
2018.08 | 23 | F.01U.168.332
Installer button, page 66
Manufacturer authorization, page 59
Select Control Center > Behavior >Outputs Available For Direct Command.
Using the schedule wizard, enter the time when the output is to be switched on/off.
As action, select Output ON or Output OFF.
The schedule can optionally be edited at the control center. Schedule > Behavior > May
Be Edited At Control Center.
Assign the point to the local area of the control center.
Select EN50131 grade 3 as the default property values setting (refer to Standard-
compliant programming, page 58).
If the panel validation in accordance with EN 50131 grade 3 fails, do not proceed with
programming the panel.
Installation manual
MAP 5000