Power Consumption; Maximum Power Dissipation - ADC H4TU-C-231-L1 User Manual

Table of Contents

Advertisement

Appendix A - Specifications
System
One-way DS1 Delay
Wander (Looped)
Wideband Jitter (Looped)
Narrowband Jitter (Looped)
P
C
OWER
ONSUMPTION
The three most important power parameters of an H4TU-C are its maximum power consumption, its maximum
power dissipation and its maximum current drain.
Table 20
describes line-powered and locally powered (remote) circuits on the maximum reach condition (34 kft.)
using 26 AWG wire.
Number of
Remote Power
Doublers
Source
None
Locally powered
None
Line-powered
1
Locally powered
1
Line-powered
2
Locally powered
2
Line-powered
M
P
AXIMUM
OWER
The maximum power dissipation measures the power that is converted into heat that builds up within the unit. It
contributes to the total heat generated in the space around the unit. It is used to determine the maximum number
of fully loaded shelves per bay that does not exceed the maximum allowable power dissipation density in watts
per square foot to comply with GR-63.
In COs, the maximum power dissipation for open-faced, natural convection-cooled mountings is limited to
134.7 watts per square foot per GR-63-CORE. Use this limit and the parameters in
determine the maximum number of H4TU-C circuits that can occupy one CO bay.
This is a worst case situation since it assumes the entire CO is subjected to the maximum power
density. More favorable conditions would permit increasing the number of shelves per bay
without jeopardizing the CO thermal integrity.
The thermal loading limitations imposed when using the H4TU-C in a Controlled Environmental Vault (CEV) or
other enclosures are determined by applying its power parameters to the manufacturer's requirements for each
specific housing.
60
<700 µs
Meets MTIE T1.101 requirements
0.2 UI maximum
0.1 UI maximum
Table 20. H4TU-C Power Parameters
-48 Vdc Power Consumption
(Watts)
Typical
Maximum
7.6
8.4
11.0
12.1
14.6
16.1
20.0
22.0
26.7
29.4
32.9
36.2
D
ISSIPATION
September 12, 2003
Heat Dissipation (Watts)
Typical
Maximum
5.9
6.4
6.2
6.8
6.6
7.2
7.1
7.8
8.4
9.2
9.3
10.3
Table 21 on page 61
LTPH-UM-1138-02, Issue 2
-42.5 Vdc Current (mA)
Typical
Maximum
179
197
259
285
344
378
471
518
628
691
774
852
to
H4TU-C-231 List 1