Front-Panel Display Messages - ADC H4TU-C-231-L1 User Manual

Table of Contents

Advertisement

LTPH-UM-1138-02, Issue 2
Table 2
lists the front-panel display messages. The four-character display reports the code of a pertinent alarm,
loopback, or diagnostic message and, in some cases, is followed by a second four-character message that modifies
the first message with a value or current configuration setting.
Message
Full Name
ALARM MESSAGES
ACO
Alarm Cutoff
ALRM
Alarm Condition Exists
DBER
DS1 Bit Error Rate
DU1U or DU1D
Doubler 1 Upstream or
Downstream Port
DU2U or DU2D
Doubler 2 Upstream or
Downstream Port
HBRx
HDSL4 Block Error Rate Loop 1 or
Loop 2
LAx
Loop Attenuation Loop 1 or Loop 2 The attenuation on the HDSL4 loop has exceeded the maximum threshold
LAIS
Line Alarm Indication Signal
LLOS
Line Loss of Signal
LOF
Loss of Frame
LOSW
Loss of Sync Word
LRAI
Line RAI
MALx
Margin Alarm Loop 1 or Loop 2
PWR FEED GND
Power Feed Ground
PWR FEED OPEN Power Feed Open
PWR FEED SHRT Power Feed Short
PRMF
Performance Report Messaging -
Far End
PRMN
Performance Report Messaging -
Near End
RAIS
Remote Alarm Indication Signal
RLOS
Remote (Unit) Loss of Signal
RRAI
Remote RAI—Remote Alarm
Indication at the H4TU-R (Net
signal has errors.)
SPNn
Span Number
TUC
Transmission Unit Central Office
TUR
Transmission Unit Remote End
H4TU-C-231 List 1
Table 2. Front-Panel Display Messages
Description
A system alarm has occurred, and has been retired to an ACO condition by
pressing the SEL pushbutton on the H4TU-C front panel.
A system alarm condition is in effect.
A system DS1 BER alarm is in effect and remains in effect until cleared.
Precedes LA, HBR, and MAL and indicates the first H4D doubler HDSL4
upstream or downstream interface.
Precedes LA, HBR, and MAL and indicates the second H4D doubler HDSL4
upstream or downstream interface.
A system HDSL4 Block Error Rate alarm is in effect. (x indicates Loop 1 or
Loop 2.)
value. (x indicates Loop 1 or Loop 2.)
Indicates an AIS (unframed all ones) pattern is being received or
transmitted at the H4TU-C DS1 input or output ports.
Indicates that no signal is detected at the DSX-1 input to the H4TU-C.
Causes a system alarm.
The DS1 input does not contain the ESF or SF frame pattern setting of the
FRMG option.
Indicates that one of the HDSL4 loops has lost synchronization.
Indicates an RAI alarm (yellow) from the CPE with an error-free signal
from the line unit or network. RAI signal is transmitted towards the
network.
The margin at Loop 1 or Loop 2 of the HDSL4 interface has dropped below
the threshold (0 to 15 dB) set by the operator. (x indicates Loop 1 or
Loop 2.)
The HDSL4 loop is grounded.
Indicates a line power open condition.
Indicates a short between the Loop 1 and Loop 2 of the HDSL4 pair.
H4TU-R PRM-FE BER threshold has been exceeded at far end.
H4TU-R PRM-NE BER threshold has been exceeded at near end.
Indicates an AIS (unframed all ones) pattern is being received or
transmitted at the H4TU-R DS1 input or output ports.
Indicates that no signal is detected at the DS1 input to the H4TU-R. Causes
a system alarm.
Indicates an RAI alarm (yellow) from the CPE with errors from the line unit
or network. RAI-CI signal is transmitted towards the network.
Accompanies the LOSW alarm and identifies the span where the LOSW
alarm occurred.
Accompanies the DBER, HBER, MAL, LA, and LOF alarms and indicates
that the alarm has occurred at the H4TU-C central office unit.
Accompanies the DBER, HBER, MAL, LA, and LOF alarms and indicates
that the alarm has occurred at the H4TU-R remote unit.
September 12, 2003
Front Panel
5