Return of AC Power

Battery Mode
When the UPS is operating during a power outage, the
is provided by the battery. When the utility power returns, the UPS transfers to Online mode operation while
the battery recharges. If battery capacity becomes low while on Battery mode, the audible alarm beeps once
every 3 seconds. This warning is approximate, and the actual time to shutdown may vary significantly.
Shutdown all applications on the connected equipment because automatic UPS shutdown is imminent. When
utility power is restored after the UPS shuts down, the UPS automatically restarts.
Low-Battery Warning
The
The audio alarm beeps every three seconds.
The remaining battery power is low. Shut down all applications on the connected equipment because
automatic UPS shutdown is imminent.
End of battery backup time
LCD displays "End of backup time".
All the LEDs go OFF.
The audio alarms stops.
Bypass Mode
In the event of a UPS overload or internal failure, the UPS transfers your equipment to utility power. Battery
mode is not available and your equipment is not protected; however, the utility power continues to be passively
filtered by the UPS. The
Bypass mode for at least 5 seconds and will stay in this mode if three transfers to Bypass occur within 20
minutes.
The UPS transfers to Bypass mode when:
the user activates Bypass mode through the front panel.
the UPS detects an internal failure.
the UPS has an overtemperature condition.
the UPS has an overload condition listed in
The UPS shuts down after a specified delay for overload conditions listed in
remains on to alarm the fault.
5 5 . . 5 5
R R e e t t u u r r n n o o f f A A C C P P o o w w e e r r
Following an outage, the UPS restarts automatically when AC input power returns (unless the restart function
has been disabled) and the load is supplied again. See the
enabled.
5 5 . . 6 6
S S e e t t t t i i n n g g H H i i g g h h E E f f f f i i c c i i e e n n c c y y m m o o d d e e
In High Efficiency mode, the UPS operates normally on Bypass and transfers to Online (or Battery) mode in less
than 10 ms when utility fails. Transfers to High Efficiency mode will be active after 5 minutes of Bypass voltage
monitoring: if Bypass quality is not in tolerance, then the UPS will remain in Online mode.
Eaton recommends to use the HE mode only to protect IT equipment.
To set the High Efficiency mode:
26
Tripp Lite by Eaton SmartOnline Series User Guide 614-21326—Rev 01
indicator illuminates solid.
indicator illuminates. Depending on overload conditions, the UPS remains in
indicator illuminates solid. The necessary energy
8.1 Model Specifications
.
4.5 User Settings
8.1 Model Specifications
. The UPS
to verify the auto restart setting is