Acoustics; Electromagnetic Immunity - Seagate Momentus 5400.5 320GB Product Manual

Seagate momentus 5400.5 320gb: user guide
Table of Contents

Advertisement

2.11

Acoustics

Drive emission of sound is measured consistent with the ECMA-74 and its' referenced standards. Testing is
conducted at room temperature (approximately 25
sound power levels for steady state, idle, and active seek modes of operation.
Table 5:
Drive A-weighted Sound Power Levels (SWL, BA)
Idle*
Performance seek
2.4 bels (typ)
2.6 bels (typ)
2.6 bels (max)
2.7 bels (max)
*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and
power to operational levels.
Test for Prominent Discrete Tones (PDTs)
Seagate follows the ECMA-74 standards for measurement and identification of PDTs. An exception to this pro-
cess is the use of the absolute threshold of hearing. Seagate uses the lower limit for the threshold curve* to
discern tone audibility and to compensate for the inaudible components of sound prior to computation of tone
ratios according to Annex D of the ECMA-74 standards.
*Defined as the median curve given by ISO 389-7 (Tf curve) minus 10dB at all frequencies.
2.12

Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in
performance when subjected to the radio frequency (RF) environments defined in the following table:
Table 6:
Radio frequency environments
Test
Electrostatic discharge
Radiated RF immunity
Electrical fast transient
Surge immunity
Conducted RF immunity
Power Frequency H-field
immunity
Voltage dips, interrupts
Momentus 5400.5 SATA Product Manual, Rev. B
°
Description
Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV
80 to 2,000 MHz, 10 V/m,
80% AM with 1 kHz sine
900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz
± 1 kV on AC mains, ± 0.5 kV on external I/O
± 1 kV differential, ± 2 kV common, AC mains
150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz
sine
1 A/m, 50Hz/60Hz, 3 axes
30% Reduction for 25 cycles
>95% Reduction for 250 cycles
>95%, 0.5 cycles
C). Emission levels are reported as the total A-weighted
Performance
level
B
A
B
B
A
A
C
C
B
Reference
standard
EN 61000-4-2: 95
EN 61000-4-3: 96
ENV 50204: 95
EN 61000-4-4: 95
EN 61000-4-5: 95
EN 61000-4-6: 97
EN 61000-4-8: 97
EN 61000-4-11: 94
13

Hide quick links:

Advertisement

Table of Contents
loading