Installation: Scotsman IS or RS Dispenser
Assembly:
The assembly of the ice machine onto the
dispenser requires two additional parts: an adapter
kit and a thermostat stand off kit.
1. Mark two spots on the inside left liner of the
dispenser: 2" down from the top, 4" from the back,
and 4" apart.
2. At the two marked spots, drill two 1/4" holes thru
the plastic liner only.
3. From the stand off kit, locate the stand offs and
plastic anchors. Thread the stand offs partially into
the plastic anchors.
4. Push the anchors/stand offs into the holes.
5. Screw the stand offs all the way into the
anchors. Be sure that the holes in the stand offs
are horizontal.
6. Place a bead of silastic (from the kit) around the
stand offs.
K1 Kit Adapter
Stand Offs From Kit K6
Drill 2 Holes For
Stand-Offs:
2" From Top Of
Dispenser &
4" From Back &
4" Apart
Route Capillary
Tube Through Front
Plastic Tube
Route Capillary
Tube Through
Stand Offs
January 1995
Page 7
7. From the adapter kit, place the stainless steel
adapter onto the top of the dispenser. Follow all
directions included with the kit.
8. After the ice machine has been placed on the
dispenser, remove the front panel and uncoil all of
the bin thermostat capillary tube.
9. Route the capillary tube thru the front hole in the
base of the ice machine, to the left side if the
dispenser towards the stand offs.
10. Route the end of the capillary tube thru the
stand offs, bend the tube around the stand offs so
that it does not fall off.
11. Check that the routing of the capillary tube is
away from the ice chute and up high near the base
of the ice machine.
Installation of Bin Thermostat