OPERATING CHARACTERISTICS

Typical Low Side Pressure
28 - 32 PSIG
Typical Discharge Side Pressure
240 PSIG, will vary bewteen 180 and 380 depending upon air and water temperatures
Refrigerant Charge
208 ounces of R-404A
Typical Compressor Amp Draw
8 - 9
Typical Gearmotor Amp Draw
3.5 to 3.8
High Pressure Cut Out
450 PSIG
Pump Down Pressure Switch - after May 1995 production
Opens at 15 PSIG (was 2 PSIG)
Closes at 30 PSIG (was 17 PSIG)
Compressor
RS58CiE-PAA-213
Bin Control
Electric Eye at base of ice chute.
Water Safety
Thermistor in reservoir