SERVICE SPECIFICATION
In servicing a machine, it is often, useful to
compare that individual units operating
characteristics to those of a normally operating
machine. The data that follows gives those
characteristics; however, be aware that these
values are for NEW, CLEAN machine operating
at 21 °C ambient and 15 °C water. USE THESE
NUMBERS AS A GUIDELINE ONLY.
Disch.
Pressure
MODEL
Freeze max Freeze min CUT OUT Beginning end Freeze
bar
SV 145 A - 230/50/1
SV 145 W - 230/50/1
SV 205 A - 230/50/1
SV 205 W - 230/50/1
SV 225 A - 230/50/1
SV 225 W - 230/50/1
SV 325 A - 230/50/1
SV 325 W - 230/50/1
SV 395 A - 230/50/1
SV 395 W - 230/50/1
SV 545 A - 400/50/3
SV 545 W - 400/50/3
Refrigerant charge R 404 A - gr.
MODEL
Air cooled
Water cooled
Refrigerant metering device
Thermostatic expansion valve.
Disch.
Hi
Pressure
Pressure
bar
bar
17,5
15,5
30
17
17
30
18
15,6
30
17
16,6
30
17,5
15,5
33
16,5
16,5
33
18
16
33
16,5
16,5
33
18,5
16,5
33
16,5
16,5
33
16
14
33
16,5
16,5
33
MV 306
MV 426
500
800
450
600

OPERATING CHARACTERISTICS

On air-cooled models during the freezing cycle,
the discharge pressure is maintained between
two preset values by means of fan control
(condenser sensor); and at the same time, the
suction pressure will also decline reaching it's
lowest point just before harvest. Compressor
amps experience a similar drop.
On water-cooled, the discharge pressure is
constantly, maintained during the freeze cycle by
the water regulating valve. However, suction
pressure and compressor amps, will still decline
as the machine freezes ice.
Suction
Suction
Pressure
Pressure
Cycle time
minutes
Freeze bar
bar
5,4
3,2
4,9
3,2
5,1
3,1
4,6
3,1
3,5
2,0
3,5
2,2
2,7
1,5
3,2
1,7
2,0
1,8
3,5
1,9
2,9
1,6
3,2
1,8
MV 456
MV 606
700
850
500
550
NOTE: Always check nameplate on individual
icemachine for special refrigerant charge
before charging the refrigeration system.
Such refrigerant charge is the average charge
for the SV Modular Cubers. However it is
important to check nameplate for each
machine.
Page 25
Amps
Amps
Compressor Compressor
Beginning
end
Freeze
Freeze
17
3,8
3
17,5
3,3
2,9
13
4,8
3,8
13,6
4,3
3,6
15
4,7
3,6
16
4,2
3,4
13
6,2
4,8
13
5,8
4,5
12,5
8,6
6,4
14,5
9,0
6,7
12
3,7
3,0
13,5
3,6
2,8
MV 806
MV 1006
1300
1600
650
1200

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sv 325Sv 395Sv 545

Table of Contents