For The Plumber - Scotsman NME650R Service Manual

Scotsman nme650r ice machine: user guide
Table of Contents

Advertisement

NME650R

FOR THE PLUMBER

FIELD
SUPPLIED
WATER FILTER
HAND SHUT
OFF VALVE
CONNECT TO
COLD WATER
VENT BIN DRAIN
3/4" FPT
FLOOR DRAIN
CONFORM TO ALL APPLICABLE CODES
WATER INLET
3/8" MALE
FLARE
The recommended water supply is
cold water. Use 3/8" O.D. copper
tubing, connect to the 3/8" male flare
at the back of the cabinet. Install a
hand valve near the machine to
control the water supply.
There is one 3/4" FPT drain at the
VENT
back of the cabinet, the drain line is of
ICEMAKER
the gravity type, and 1/4 inch per foot
DRAIN,
3/4" FPT
fall is an acceptable pitch for the drain
tubing. There should be a vent at the
highest point of the drain line, and the
ideal drain receptacle would be a
trapped and vented floor drain. Use
only 3/4" rigid tubing.
Storage Bin: A separate gravity type
drain needs to be run. Insulation of
this drain line is recommended.
June 1994
Page 8
Water Inlet
Drains