For The Installer: Remote Condenser - Scotsman FME1500R Service Manual

Scotsman fme1500r ice machine: user guide
Table of Contents

Advertisement

FOR THE INSTALLER: Remote Condenser

Installation Limitations:
This ice system is designed to be installed indoors,
in a controlled environment:
Air Temperature
Water Temperature
Water Pressure
Voltage
(Compared to the nameplate)
The temperature limitations do not apply to the
remote condenser. It will work between -20
degrees F, and 120 degrees F.
SPECIFICATIONS: REMOTE CONDENSER
Model
Use with
RCE651-32
1 FME1500R
ERC201-32
SAME
RCE652-32
1 or 2 FME1500Rs*
ERC402-32
SAME
RTE25 Precharged line set, 25'. R-404A
RTE40 Precharged line set, 40'. R-404A
* Two machines on one condenser require a fan relay kit.
Icemaker Nameplate Located On Back Panel
Serial Plate Located Behind Front Panel
Min.
Max.
0
0
50
F
100
F
0
0
40
F
100
F
20 psi 80 psi
5%
+10%
ERC DIMENSIONS
Model
ERC201
ERC402
Basic Electrical
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
December 1995
Page 3
Operating the machine outside of the limitations is
misuse and can void the warranty.
Scotsman Ice Systems are designed and
manufactured with the highest regard for safety
and performance. They meet or exceed the
standards of UL, NSF, and CSA.
Scotsman assumes no liability or responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the
use of any part and/or other components not
specifically approved by Scotsman.
Scotsman reserves the right to make design
changes and/or improvements at any time.
A
B
3
3
33
"
10
"
8
4
3
3
43
"
10
"
8
4
13
23
"
16
7
19
"
8
FME1500R
F
G
3
5
16
"
11
"
4
8
3
5
21
"
16
"
4
8

Advertisement

Table of Contents
loading

Table of Contents