REMOVAL AND REPLACEMENT
TRANSDUCER
1. Disconnect electrical power BEFORE removing
transducer.
2. Open bin door and locate the transducer socket.
3. Twist inner portion of transducer counter-
clockwise and push up gently.
4. Pull transducer down until plug connection is
accessible.
TRANSDUCER LOCATION
TRANSDUCER
CME865W & CME1002W
5. Unplug transducer and remove from the
machine.
6. Reverse steps 1-5 to reassemble.
December, 1994
Page 23
CONNECTION
REMOVAL OF TRANSDUCER
SOCKET IN ICE
MACHINE BASE
PLUG