PRE-INSTALLATION PREPARATION
• When locating termination cap, it is impor-
tant to observe the minimum clearances
shown in Figure 7, page 7.
• If recessing into a wall, you can avoid extra
framing by positioning your fireplace against
an already existing framing member.
• Do not recess termination cap into a wall
or siding.
• You may paint the termination cap with
450º F (232º C) heat-resistant paint to
coordinate with the exterior finish.
• There must not be any obstruction such
as bushes, garden sheds, fences, decks
or utility buildings within 24" from the front
of the termination cap.
• Do not locate termination cap where exces-
sive snow or ice build up may occur. Be sure
to clear vent termination area after snow falls
to prevent accidental blockage of venting
system. When using snow blowers, do not
direct snow towards vent termination area.
(63.5 cm)
15"
(38.1 cm)
(91.4 cm)
Figure 3 - Fireplace Bottom Dimensions
PACKAGING AND REMOvAL
The (V)CD36R/T direct vent gas fireplace
heater is packaged with:
• one box containing a 4-log set located on
the burner in the firebox
• one bag containing the owner's manual
with installation instructions, operator's
guide, and warranty information
• one bag of glowing ember material
• one bag of vermiculite hearth treatments
Remove the shrink-wrap securing the 2 carton
trays to the unit. Lift the top carton tray off
and remove the four corner posts. Discard
the bottom tray once the unit is moved into
position.
Note: On rear vent models you must remove
the fiberboard collar protector located on the
rear collar before installing the fireplace and
venting system. See Figure 4.
6
Continued
CLEARANCES
Minimum clearances to combustibles for the
fireplace are as follows:
*Back and sides
Perpendicular walls
Floor
25"
Ceiling to louver opening
Front
Top of Standoffs
Vent Surfaces
Mantel Clearances (See Mantel Clearances
36"
Combustible material with a maximum thick-
ness of 5/8" may be flush with the top front
of fireplace.
www.desatech.com
Figure 4 - Removing Collar Protector
(Rear Vent Fireplace)
1" (26 mm) (See venting
instructions for specific
vent clearances.)
for specifics on mantel
clearances.)
NOTICE: This fireplace is in-
tended for use as supplemental
heat. Use this fireplace along
with your primary heating sys-
tem. Do not install this fireplace
as your primary heat source.
If you have a central heating
system, you may run system's
circulating blower while using
fireplace. This will help circulate
the heat throughout the house.
In the event of a power outage,
you can use this fireplace as a
heat source.
Fire Board
Collar
Protector
0"/cm
12" (30.5 cm)
0"/cm
40" (102 cm)
36" (91.4 cm)
0"/cm
116035-01J