8. Push in gas control knob all the way and
hold. Immediately light pilot by repeatedly
pressing the piezo spark ignitor until a
flame appears. Continue to hold for about
one (1) minute after pilot is lit. Release
gas control knob and it will pop back. Pilot
should remain lit. If it goes out, repeat
steps 5 through 8.
• If gas control knob does not pop up when
released, stop, turn off gas supply and
immediately call your service technician
or gas supplier.
• If pilot will not stay lit after several tries,
turn gas control knob to OFF and call
your service technician or gas supplier.
9. Turn on all electric power to fireplace.
10. Turn gas control knob counterclockwise
to ON.
11. This valve is equipped with a HI/LO fea-
ture. Set fireplace input as desired.
12. To leave pilot lit and shut off burners only,
turn gas control knob clockwise
the PILOT position. Set wall switch or HRC
selector switch to the OFF position.
13. Close lower louver panel.
TO TURN OFF GAS
TO AppLIANCE
1. Open lower louver panel.
2. Set wall switch to the OFF position or the
HRC selector switch (when equipped) to
prevent draining the battery.
3. Turn off all electric power to appliance if
service is to be performed.
4. Push in gas control knob slightly and turn
clockwise
to OFF.
5. Close lower louver panel.
6. Close equipment shutoff valve (see Figure
53, page 29).
MANUAL LIGHTING
pROCEDURE
1. Remove glass door (see Removing/Re-
placing Glass Door, page 30).
2. Follow steps 1 through 8 under Lighting
Instructions, page 32.
3. Press gas control knob and light pilot with
match.
116035-01J
OPERATION
Continued
MILLIVOLT MODELS
4. Keep gas control knob pressed in for
30 seconds after lighting pilot. After 30
seconds, release gas control knob. Fol-
low steps 9 through 12 under Lighting
Instructions, column 1.
5. Replace glass door (see Removing/Re-
placing Glass Door, page 30).
Note: All remote control accessories must
be purchased separately (see Accessories,
page 52). Follow instructions included with
the remote control.
NOTICE: you must light the pilot
before using the hand-held re-
mote control unit. See Lighting
Instructions, page 30.
After lighting, let pilot flame burn for about
one minute. Turn control knob to ON position.
to
Adjust flame adjustment knob anywhere be-
tween HI and LO. Slide selector switch to the
REMOTE position (see Figure 62).
Note: Burner may light if hand-held remote
was on when selector switch was last turned
off. You can now turn burner on and off with
hand-held remote control unit.
IMPORTANT: Do not leave selector switch in
the REMOTE or ON position when pilot is not
lit. This will drain the battery.
Blower Control Knob
(Optional Accessory)
Selector Switch in
Remote Position
Figure 62 - Setting the Selector Switch,
Gas Control Knob and Variable Control
www.desatech.com
OpTIONAL HAND-HELD
REMOTE OpERATION
Variable Control
Knob
OFF
ON
Gas Control Knob
in ON Position
Knob for Remote Operation