Correct Use - GEM 0326 2M 74 41G4010810 Operating Instructions Manual

Electrically operated pilot solenoid valve
Table of Contents

Advertisement

5 Correct use

RFID chip
5 Correct use
Danger of explosion
▶ Danger of death or severe injury.
Only use the product in potentially ex-
plosive zones confirmed in the declara-
tion of conformity.
Improper use of the product!
▶ Risk of severe injury or death
▶ Manufacturer liability and guarantee will be void
Only use the product in accordance with the operating
conditions specified in the contract documentation and in
this document.
1. Use the product in accordance with the technical data.
The GEMÜ 0326 directly controlled 3/2-way pilot solenoid
valve is designed for mounting to a compact aluminium rail as
a valve battery for mounting in control cabinets or as a valve
manifold near the pneumatic components to be controlled.
The body is made of plastic. The coil is plastic encapsulated.
5.1 Product without ATEX, code 06, 08, 09
The product is not intended for use in potentially explosive
areas.
5.2 Product with ATEX, code 04, 05, 07, 11
The product with the ATEX ordering option is intended for use
in potentially explosive areas of zone 1 with gases, mists or
vapours and zone 22 with combustible dusts in accordance
with EU directive 2014/34/EU (ATEX).
The product has the following explosion protection marking:
Gas:
II 2G Ex mb II T4
GEMÜ 0326
DANGER
WARNING
Dust:
II 2D Ex tD A21 IP65 T130°C
Type examination certificate: PTB 03 ATEX 2018 X
The product has been developed in compliance with the fol-
lowing harmonised standards:
- DIN EN 60079-0:2012+A11:2013
- DIN EN 60079-7:2015
- DIN EN 60079-15:2010
- DIN EN 60079-31:2014
Use of the product is permissible in the following ambient
temperature ranges: 0 to +60 °C
For use in potentially explosive areas, the following
conditions or operation limits must be observed:
The following special conditions must be complied with:
1. Connection cables and connectors must be protected
from damage.
2. Layers of dust > 5 mm must be removed.
3. Warning label "Danger from electrostatic build-up".
4. Warning label "Do not disconnect when live".
6 / 19