Section 5 - Storage

Draining Water from the Cool Fuel Module

Mercury MerCruiser recommends draining the Gen 3 Cool Fuel Module if it is equipped with a drain plug.
1.
Remove the drain plug from the Gen 3 Cool Fuel Module and allow the water to completely drain from the module.
2.
Inspect the drain plug and the O‑ring for damage. Replace if needed.
3.
Place the O‑ring on the drain plug and apply Perfect Seal to the threads. Install the drain plug in the module drain hole.
Tighten the drain plug to finger‑tight.
a
c
Tube Ref No.
Perfect Seal
19

Draining the Sterndrive

NOTE: This procedure is needed only for salty, brackish, mineral‑laden, or polluted water applications; and for freezing
temperatures or extended storage.
1.
Insert a small wire repeatedly to ensure that vent holes, water drain holes, and passages are unobstructed and open.
d
a
Sterndrive water drain holes
a -
Speedometer pitot tube
b -
Trim tab cavity vent hole
c -
Trim tab cavity drain passage
d -
Gear housing water drain hole (1 each ‑ port and starboard)
e -
Gear housing cavity vent hole
f -
Gear housing cavity drain hole
The universal joint bellows may develop a set when stored in a raised or up position, causing the bellows to fail when
returned to service and allowing water to enter the boat. Store the sterndrive in the full down position.
Page 92
b
Description
e
b
a -
Gen 3 Cool Fuel Module
b -
Drain plug
c -
O‑ring
50410
Where Used
Drain plug threads
NOTICE
f
c
6146
90-8M0128976
Part No.
92-34227Q02
MAY 2017
eng