Connecting A F3Sj-B To Four Muting Sensors - Omron F3SJ-E P25 Series User Manual

Safety light curtain
Hide thumbs Also See for F3SJ-E P25 Series:
Table of Contents

Advertisement

Input/Output Circuit and Applications

Connecting a F3SJ-B to Four Muting Sensors

F39-JD A-L
Workpiece
KM1, KM2, KM3, KM4 N.O. contact
KM1, KM2, KM3, KM4 N.C. contact
F3SJ-E/B
104
User's Manual
Communication
line (+) (Gray)
Communication
line (-) (Pink)
Reflector
B1
B2
A1
F3SJ-B
A2
+24 VDC
Power
0 V
Supply
Unblocked
Blocked
A1 Safety output
B1 Safety output
B2 Safety output
A2 Safety output
Muting input 1
Muting input 2
Safety output
External indicator
F39-JD A-D
Feedback loop
ML
+24 V
A1
T11
T12 T21 T22
T31 T32 T33 Y1
Open
Open
Control circuit
A2
S14 S24
S34 S44 S54
L1
X1 X2
KM1 KM2
KM3 KM4
PLC,etc.
S1
Motor controller
S2
(operation command)
KM1 to KM4 : Safety relay with force-guided contact (G7SA)
M1, M2
ML
PLC
*1. Also used for override input.
*2. Under muting system, connect to 0 V as the external device monitoring
cannot be used.
Wiring for manual reset mode
S3
- F3SJ-B settings
- Muting system
- Does not use external device monitoring function
- G9SX-AD322-T15 settings
- Auto reset mode
- Using feedback loop
Motor controller
KM1
KM1
KM3
KM2
KM2
KM4
KM3
M1
KM4
+24 V
AND
T41 T42
Open Open
OFF
Model G9SX-AD322-T15
: External test switch (connect 0 V if a switch is not required)
: Lockout reset switch (connect to 24 V if a switch is not required)
or magnetic contactor
: 3-phase motor
: External indicator
: Programmable controller
(Used for monitoring -- not related to safety system)
Feedback loop
KM1
KM2
KM3
KM4
+24 V
T31
T32 T33 Y1
S3 : Reset switch
S34
M2

Advertisement

Table of Contents
loading

This manual is also suitable for:

F3sj-b p25 series

Table of Contents