Resetting Phenomenon Often Occurs During Operation; Operation Lamp Flashes And Timer Lamp Off; Operation Lamp Flashes And Timer Lamp On - Fisher FSI-95HFD Service Manual

Table of Contents

Advertisement

13.3 Resetting phenomenon often occurs during operation

(That is automatically entering to the status when power is on.)
The reason is that the instantaneous voltage of main chip is less than 4.5V. Check according to the
following procedure:

13.4 Operation lamp flashes and Timer lamp off

Is connector connection good?
Is voltage being applied to the fan motor?
Fan motor is defective

13.5 Operation lamp flashes and Timer lamp on

34
Yes
Service manual
No
Repair the connector.
No
Indoor PCB is defective.