Toshiba RAS-18S3KV-E Service Manual page 63

Hide thumbs Also See for RAS-18S3KV-E:
Table of Contents

Advertisement

Model
Power source
Maximum running current
Plug socket & fuse rating
Power cord
H07RN-F or 60245 IEC66 (4.0 mm
H07RN-F or 60245 IEC66 (1.5 mm
Connecting cable
CAUTION
• Wrong wiring connection may cause some electrical
parts burn out.
• Be sure to comply with local cords on running the
wire from indoor unit to outdoor unit (size of wire
and wiring method, etc.).
• Every wire must be connected firmly.
• This installation circuit breaker must be used specified
for the power supply line of this air conditioner.
• If incorrect or incomplete wiring is carried out, it will
cause an ignition or smoke.
• Prepare the power supply for exclusive use with the
air conditioner.
• This product can be connected to the mains.
Connection to fixed wiring: A switch which
disconnects all poles and has a contact separation
of at least 3 mm must be incorporated in the fixed wiring
10-5. Others
10-5-1. Gas leak test
Check places
for outdoor unit
F ig. 10-5-1
• Check the flare nut connections for the gas leak with
a gas leak detector or soap water.
18 Class
22 Class
220 - 240V Single phase, 50Hz
220V Single phase, 60Hz
10.0A
13.5A
12.5A
17.0A
Check places for
indoor unit (Flarenut
connection)
10-5-2. Remote Control A-B Selection
• When two indoor units are installed in the same room or
adjacent two rooms, if operating a unit, two units may
receive the remote control signal simultaneously and
operate. In this case, the operation can be preserved
by setting either one remote control to B setting.
2
)
(Both are set to A setting in factory shipment.)
• The remote control signal is not received when the
2
)
settings of indoor unit and remote control are different.
• There is no relation between A setting/B setting and A
room/B room when connecting the piping and cables.
<Remote control A-B selection>
To separate using of remote control for each indoor unit
in case of 2 air conditioners are installed nearly.
<Remote Control B Setup>
1. Press [RESET] button on the indoor unit to turn the air
conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold [CHECK] button on the Remote Control
by the tip of the pencil. "00" will be shown on the display
(Picture
1
4. Pres s [ MODE] during pushing [CHECK]. "B" will show
on the display and "00" will disappear and the air
conditioner will turn OFF. The Remote Control B
is memorized (Picture
NOTE : 1. Repeat above step to reset Remote
Control to be A.
2. Remote Control A has not "A" display.
3. Default setting of Remote Control from
factory is A.
– 62 –
FILE NO. SVM-15009
).
).
2
1
F ig. 10-5-2
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-22s3kv-eRas-18s3av-eRas-22s3av-e

Table of Contents