7.3 Initial Network Configuration
After the system has been connected to the power supply and to the antenna, the initial start-up can be started.
The device starts immediately after connection to the power supply.
An IMS LANTIME system is shipped with DHCP service enabled on the LAN 0 interface. This means that you
have to establish a manual network connection if no DHCP service is installed in your network environment in
order to perform system settings via the web interface.
Serial connection with Basic Configuration Wizard (without LC display).
After switching on the device, a terminal program (e.g. Putty) can be started after about one minute. Connect
the system's serial interface (TERM/CONSOLE) with a null modem cable or a CAB-CONSOLE-RJ45 cable.
The settings for the interface must be set to 38400 baud, 8 data bits, no parity and one stop bit (8N1). The
terminal emulation must be set to VT100. Computers without serial interface can be connected with a "Serial-to
USB" converter.
After connection is established, the prompt for the user ID should be displayed:
Welcome to Meinberg LANTIME
login: _
Default user: root
Default password: timeserver
(press RETURN again if necessary)
Change with the console to the directory /wizard/. The LANTIME Basic Configuration Wizard can now be
started with the "startwizard" command.
48
Date: August 11, 2023
IMS - LANTIME M3000S