Model
Pump Model
970159
Quiet Kingt
970160
Quiet Kingt
970163
Quiet Kingt
Sound Data
Part No.
Pump Model
970159
Quiet Kingt
970160
Quiet Kingt
970163
Quiet Kingt
*
Sound pressure was measured in accordance with Cagi Pneurop, 1969.
**
Sound power was measured in accordance with ISO 3744, 1981.
Main air inlets [for 970159 (1) and 970160 (2)]
Main air inlet (for 970163)
Material outlets [for 970159 (2), 970160 (2), and 970163 (1)]
Maximum fluid flow (at 60 cpm)
Air consumption (at 75 psi and 60 cpm)
Wetted parts
Technical Data
Displacement
Pump Model
Dura–Flowt 2400
Dura–Flowt 2400
Dura–Flowt 2400
Air Pressure of Sound
Tests (25 cycles/min)
6 bar, 0.6 MPa (90 psi)
6 bar, 0.6 MPa (90 psi)
6 bar, 0.6 MPa (90 psi)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
Fluid outlet fittings: zinc or cadmium–plated carbon steel
Maximum Fluid
Ratio
Working Pressure
20:1
345 bar, 34 MPa
(5000 psi)
20:1
345 bar, 34 MPa
(5000 psi)
20:1
345 bar, 34 MPa
(5000 psi)
* Sound Pressure
Level
88 dBa
88 dBa
88 dBa
. . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
3.8 scfm (2.8 m
Maximum Pump
Air Input Pressure
6 bar, 0.6 MPa
(90 psi)
6 bar, 0.6 MPa
(90 psi)
6 bar, 0.6 MPa
(90 psi)
** Sound Power
Level
103 dBa
103 dBa
103 dBa
3/4 in. npsm(f)
1/2 in. npt(f)
1–1/4 in. npt(f)
9 gpm (35 lpm)
3
/min)
310334
21