Chapter 2
Installing the Base Station
Kits
• Class I, Division 2 Kit (P/N MKIT0109) – For hazardous
locations only
Tools
• Wrench or socket set
• Phillips screwdriver
• Drill with an 8 mm (5/16 in) drill bit
Sprays
• Cleaner and de-greaser
• SCC3 conformal coating
• Corrosion protection
Section 2.4

Site Preparation and Precautions

Before installing the base station and or antenna(s), it is important to plan the the complete installation and make
sure the appropriate safe guards are in place.
Site Selection
Consider the following recommendations when selecting an appropriate site for the base station and antenna(s):
• Mount the antenna(s) at the highest point possible. Reception will increase according to the height of the
antenna(s).
• Mount the antenna(s) in a place with as few obstructions as possible between the antenna(s) and the planned
service area.
• To avoid interference, mount the antenna(s) and base station as far as possible from other antenna(s) and base
stations.
• Keep the cable from the base station to the antenna(s) as short as possible and mount the antenna(s) as
close as possible to the base station. Using a cable longer than 2 m (6.6 ft) will result in greater loss and more
interference, as the cable will act as an antenna itself.
• Do not point the antenna(s) directly at populated areas.
• Locate the antenna(s) at least 3.6 m (11.8 ft) from people and public areas.
• Make sure the antenna(s) and base station are easily accessible for maintenance purposes.
• Mount the GPS antenna in a position where the whole sky is visible to the antenna. If the base station is
mounted on a wall and the GPS antenna is mounted on top of the base station, only half of the sky will be
visible to the antenna. This may not be enough for proper operation.
• Conduct a site survey to best position the base station and antenna(s) in relation to other base stations,
antennas and subscriber stations in the area. The site survey should also take into consideration the overall
safety of the selected site
8
Greases
• Marine grease (for marine applications only)
Tapes
• POE cold shrink (maximum 49.2 mm or 1.9 in inner
diameter before shrinking) or self-amalgamating tape
• UV-resistant vinyl tape
• Electrical insulation putty
Mounting Hardware (Wall/Tower Only)
• Four 8 mm (5/16 in) screws
• Four 8 mm (5/16 in) flat washers
• Four 8 mm (5/16 in) spring washers
• Wall anchors (if necessary)