Greenheck KSQ Installation, Operation And Maintenance Manual

Greenheck KSQ Installation, Operation And Maintenance Manual

Direct drive rooftop supply mixed flow fans

Advertisement

Quick Links

®
Installation, Operation and Maintenance Manual
Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,
operate or maintain the product described. Protect yourself and others by observing all safety information. Failure
to comply with these instructions will result in voiding of the product warranty and may result in personal injury
and/or property damage.
Rooftop Supply Mixed Flow Fans
Fans are direct-driven with mixed flow wheels and feature
rigid construction, high efficiency, and low sound levels. These
fans are designed for filtered roof supply applications such as
providing non-tempered make-up air. The fans are available in
twelve sizes and feature permanent, washable aluminum filters.
General Safety Information
Only qualified personnel should install this fan.
Personnel should have a clear understanding of these
instructions and should be aware of general safety
precautions. Improper installation can result in electric
shock, possible injury due to coming in contact with
moving parts, as well as other potential hazards. If more
information is needed, contact a licensed professional
engineer before moving forward.
1. Follow all local electrical and safety codes, as well as
the National Electrical Code (NEC) and the National
Fire Protection Agency (NFPA), where applicable.
Follow the Canadian Electric Code (CEC) in Canada.
2. The rotation of the wheel is critical. It must be free
to rotate without striking or rubbing any stationary
objects.
3. Motor must be securely and adequately grounded.
4. Do not spin fan wheel faster than max cataloged fan
RPM. This could cause catastrophic wheel failure.
Adjustments to fan speed significantly affects motor
load. If the fan RPM is changed, the motor current
should be checked to make sure it is not exceeding
the motor nameplate amps.
5. Do not allow the power cable to kink or come in
contact with oil, grease, hot surfaces or chemicals.
Replace cord immediately if damaged.
6. Verify that the power source is compatible with the
equipment.
7. Never open access doors to a duct or fan while the
fan is running.
8. Never remove covers protecting electrical
components while fan is energized.
®
Rooftop Supply Mixed Flow Fans
DANGER
Always disconnect, lock, and tag power source before
installing or servicing. Failure to disconnect power
source can result in fire, shock, or serious injury.
CAUTION
When servicing the fan, motor may be hot enough
to cause pain or injury. Allow motor to cool before
servicing.
DANGER
Pour écarter les risques d'incendie, de choc électrique
ou de blessure grave, veiller à toujours débrancher,
verrouiller et étiqueter la source de courant avant
l'installation ou l'entretien.
ATTENTION
Lors de toute intervention sur la soufflante, le moteur
peut être suffisamment chaud pour provoquer une
douleur voire une blessure. Laisser le moteur refroidir
avant toute maintenance.
Rooftop Supply Mixed Flow Fans
Document 486132
Model KSQ Direct Drive
1

Advertisement

Table of Contents
loading

Summary of Contents for Greenheck KSQ

  • Page 1 Document 486132 Model KSQ Direct Drive Rooftop Supply Mixed Flow Fans ® Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with these instructions will result in voiding of the product warranty and may result in personal injury and/or property damage.
  • Page 2 Receiving Storage Environment The ideal environment for the storage of fans and Upon receiving the product check to ensure all items accessories is indoors, above grade, in a low humidity are accounted for by referencing the delivery receipt or atmosphere which is sealed to prevent the entry of packing list.
  • Page 3: Dimensional Data

    Dimensional Data Intake Con gurations Intake Configurations Intake Con gurations HORIZONTAL INTAKE BOTTOM INTAKE Horizontal Intake Bottom Intake Max. Fan Size Weight^ Discharge Con gurations KSQ-7 32-1/2 16-3/8 11-3/8 15-1/4 20-3/8 16-3/8 15-1/4 KSQ-9 36-1/2 20-7/8 41-3/4 25-1/4 20-7/8 KSQ-12...
  • Page 4 Pre Start-Up Checks Before Fan Installation Operation Before starting up or operating fan, check all fasteners IMPORTANT: The fan has been checked for for tightness. In particular, check the cap screws in wheel bushing. mechanical noise at the factory prior to shipment.
  • Page 5: Typical Installation

    STEP 7 - Fasten Filter Tracks to Side Panels Fan Size Duct Size Roof Opening • Position filter tracks on the KSQ-7 8 1/4 x 8 1/4 10 1/2 x 13 1/4 opposite side of the side KSQ-9 11 1/4 x 11 1/4...
  • Page 6 (hardware supplied by others) a C-clamp locking pliers can be used to hold the duct Mating surface Horizontal Discharge Fan Size Duct Size KSQ-7 11 1/ 2 x 11 1/2 BOTTOM KSQ-9 15 1/4 x 14 1/4 SIZE 7-16 KSQ-12...
  • Page 7 STEP 13 - Install Side Panels STEP 16 - Route Wiring to Junction Box • Install with the drip edge down and align the • Route the wiring from the junction box to the half-moon cutouts on the side panel with the inlet disconnect through all conduit and outlet fasteners ®...
  • Page 8: Parts List

    STEP 18 - Install Filter(s) Fan Size Filter Size (in.) Qty. • Loosen both thumb screws on the intake hood and 18 1/4 x 10 1/2 drop filter tracks 22 x 14 1/4 • Aluminum washable filters come standard with 26 3/4 x 17 1/2 the unit 34 1/2 x 21 1/4...
  • Page 9: Maintenance

    Maintenance Tapered Bushing Hub DANGER For wheel hubs utilizing a tapered bushing interface, Always disconnect, lock and tag power source before follow this procedure for installation and removal. servicing. Failure to disconnect power source can result in fire, shock or serious injury. Bushing Removal WARNING 1.
  • Page 10: Troubleshooting

    Filters One-inch washable aluminum mesh filters are standard All fasteners should be checked for tightness each on model KSQ. Optional two-inch MERV 13 filters may time maintenance checks are performed prior to be supplied on some Bottom intake configurations. restarting unit.
  • Page 11: Maintenance Log

    Maintenance Log Date ___________________Time _____________ AM/PM Date ___________________Time _____________ AM/PM Notes: ___________________________________________ Notes: ___________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ Date ___________________Time _____________ AM/PM Date ___________________Time _____________ AM/PM Notes: ___________________________________________ Notes: ___________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ Date ___________________Time _____________ AM/PM...
  • Page 12: Our Commitment

    As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Product warranties can be found online at Greenheck.com, either on the specific product page or in the literature section of the website at Greenheck.com/Resources/Library/Literature.

Table of Contents