Greenheck SQ Brochure & Specs

Greenheck SQ Brochure & Specs

Centrifugal inline fans direct and belt drive
Table of Contents

Advertisement

Centrifugal Inline Fans
Direct and Belt Drive
®
April
2012

Advertisement

Table of Contents
loading

Summary of Contents for Greenheck SQ

  • Page 1 Centrifugal Inline Fans Models SQ and BSQ Direct and Belt Drive ® April 2012...
  • Page 2: Table Of Contents

    Warranty ......48 Greenheck Fan Corporation certifies the model SQ and BSQ fans shown herein are licensed to bear the AMCA Seal.
  • Page 3 Models SQ and BSQ Centrifugal Square Inline Duct Fans Model Comparison Drive Impeller Performance Location Mounting Airflow Application Type Type Model            5,000          ...
  • Page 4: Standard Construction Features

    Standard Construction Features Model SQ Direct Drive Model BSQ Belt Drive...
  • Page 5 Standard Construction Features Cabinet Construction Drive Assembly Drives are sized for a minimum of 150 percent The fan housing is constructed of rigid structural of driven horsepower. Machined cast iron members and formed galvanized steel panels. pulleys are factory set to the required RPM and (Aluminum construction is optional in all SQ adjustable for final system balancing.
  • Page 6 Vari-Green Options ® Vari-Green Motor - Model SQ Features ® 1. Dial on Motor Control - A potentiometer (dial on Greenheck’s motor control) is mounted on the motor for easy electronically speed adjustment for system balance. Simply turn commutated (EC) the dial there are no belts and pulleys to adjust.
  • Page 7 Vari-Green Options ® The Vari-Green constant pressure control is pre- Demand Control Ventilation for programed and easy to install for applications that Multistory Buildings include: venting dryers, bathrooms, residential type kitchen space or industrial process exhaust. Applications requiring constant pressure or variable volume can utilize SQ fans with Vari-Green motors Contact fans@greenheck.com for more information.
  • Page 8: Options And Accessories

    Options and Accessories Aluminum Construction Coatings Aluminum construction is available for all direct drive Wide variety of coatings sizes 60-160 and belt drive sizes 70-300. Some and colors are available. drive frame components may still be of galvanized Decorative coatings construction to maintain structural integrity.
  • Page 9: Filter Options

    Filter Options The filter box is designed to provide a compact and convenient clean air solution. Factory-assembled as a single unit, this fan eliminates the costly process of designing, fabricating and installing special remote filter box assemblies. Both the fan and filter section feature removable access panels on both sides to remove and replace filters, making fan maintenance simple and fast.
  • Page 10: Discharge Configurations

    Discharge Configurations Discharge Configuration The side discharge option helps to reduce system effect. It will increase performance and reduce Fan performance will change with different discharge installation labor. The most notable is reducing system positions. Catalog data is based on an inline effects.
  • Page 11 Side Discharge SQ Side Discharge BSQ Side Discharge Left Side Discharge Access Door Access Door Left Side Inline Inline Discharge Discharge Discharge Figure 4 Figure 5 Height Height Inlet Inlet Width Right Side Width Right Side Discharge Discharge SQ Side Discharge Duct Openings BSQ Side Discharge Duct Openings Unit Size Width...
  • Page 12: Mounting Options

    Horizontal and Vertical Mounting Options All SQ and BSQ fan models can be mounted horizontally, vertically or at an angle. For ease of installation, knockouts are provided at each location where mounting brackets are shown in figures 6, 7 and 8. Optional brackets are universally adjustable to mount in any of these locations.
  • Page 13: Isolators

    Base Mount or Hanging Isolators Complete isolation kits are available Standing Neoprene Isolator with either neoprene or spring isolators and are sized to match the weight of the specified fan size. The base isolator support brackets are designed to permit mounting of the fan with the motor located on top or either side.
  • Page 14: Typical Installation

    Typical Installation Models SQ and BSQ ducted inline fans are designed both. The motor is rigidly mounted and can be oriented for the exhaust, supply or recirculation of air in a in any direction (top, bottom, side). building. Typical installation requires ductwork on the The model BSQ ducted inline fan must be installed inlet and outlet side of the fan.
  • Page 15: Direct Drive

    SQ 60-65 - Direct Drive (25) 0.55 RPM (Direct) RPM (Vari Green) 0.50 Density 0.075 lb/ft Density 1.2 kg/m 0.45 ⁄ (225) 0.40 (305) 0.35 0.30 0.25 (305) 0.20 (330) 0.15 0.10 0.05 Damper size = 9 x 9 (229 x 229) Unit weight** = 26 (12) 0.00...
  • Page 16 SQ 70-75 - Direct Drive (25) 0.55 RPM (Direct) RPM (Vari Green) 0.50 Density 0.075 lb/ft Density 1.2 kg/m 0.45 ⁄ (225) 0.40 (305) 0.35 0.30 0.25 (330) 0.20 (305) 0.15 0.10 0.05 Damper size = 9 x 9 (229 x 229) Unit weight** = 26 (12) 0.00...
  • Page 17 SQ 80-85 - Direct Drive (25) RPM (Direct) RPM (Vari Green) Density 0.075 lb/ft Density 1.2 kg/m ⁄ (302) (381) (381) (406) Damper size = 12 x 12 (305 x 305) Unit weight** = 41 (19) Housing thickness = 18 ga Volume (cfm) Outlet velocity = 1.021 x cfm Dimensions shown in inches (millimeters) and weight is...
  • Page 18 SQ 90-95 - Direct Drive (25) RPM (Direct) RPM (Vari Green) Density 0.075 lb/ft Density 1.2 kg/m ⁄ (302) (381) (381) (406) Damper size = 12 x 12 (305 x 305) Unit weight** = 41 (19) Housing thickness = 18 ga 1000 Volume (cfm) Outlet velocity = 1.021 x cfm...
  • Page 19 SQ 100 - Direct Drive (25) RPM (Direct) RPM (Vari Green) Density 0.075 lb/ft Density 1.2 kg/m ⁄ (352) (432) (432) (533) Damper size = 14 x 14 (356 x 356) Unit weight** = 56 (25) 1000 1200 1400 1600 Housing thickness = 18 ga Volume (cfm) Outlet velocity = 0.748 x cfm...
  • Page 20 SQ 120 - Direct Drive (25) RPM (Direct) RPM (Vari Green) Density 0.075 lb/ft Density 1.2 kg/m ⁄ (403) (483) (483) (533) Damper size = 16 x 16 (406 x 406) Unit weight** = 67 (30) 1000 1500 2000 Housing thickness = 18 ga Volume (cfm) Outlet velocity = 0.571 x cfm 1000...
  • Page 21 SQ 130 - Direct Drive (25) RPM (Direct) RPM (Vari Green) Density 0.075 lb/ft Density 1.2 kg/m ⁄ (454) (533) (533) (533) Damper size = 18 x 18 (457 x 457) Unit weight** = 77 (35) 1000 1500 2000 2500 Housing thickness = 18 ga Volume (cfm) Outlet velocity = 0.451 x cfm...
  • Page 22 SQ 140 - Direct Drive (25) RPM (Direct) RPM (Vari Green) Density 0.075 lb/ft Density 1.2 kg/m ⁄ (505) (584) (584) (559) Damper size = 20 x 20 (508 x 508) Unit weight** = 104 (47) 1000 1500 2000 2500 3000 3500 Housing thickness = 18 ga...
  • Page 23 SQ 160 - Direct Drive (25) RPM (Direct) RPM (Vari Green) Density 0.075 lb/ft Density 1.2 kg/m ⁄ (581) (660) (660) (660) Damper size = 23 x 23 (584 x 584) Unit weight** = 160 (73) 1000 2000 3000 4000 5000 6000 Housing thickness = 18 ga...
  • Page 24: Belt Drive

    BSQ 70 - Belt Drive ⁄ (394) (356) Density 0.075 lb/ft (25) ⁄ (318) ⁄ (302) (381) (381) (533) 1000 Damper size = 12 x 12 (305 x 305) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 76 (34) *Motor cover is optional.
  • Page 25 BSQ 80 - Belt Drive ⁄ (394) (356) Density 0.075 lb/ft (25) ⁄ (318) ⁄ (302) (381) 1000 1200 (381) (533) 1000 1500 2000 Damper size = 12 x 12 (305 x 305) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 79 (36) *Motor cover is optional.
  • Page 26 BSQ 90 - Belt Drive ⁄ (394) (356) Density 0.075 lb/ft (25) ⁄ (318) ⁄ (302) (381) 1000 1200 1400 1600 1800 (381) (533) 1000 1500 2000 2500 3000 Damper size = 12 x 12 (305 x 305) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 84 (38) *Motor cover is optional.
  • Page 27 BSQ 100 - Belt Drive ⁄ (394) (356) Density 0.075 lb/ft (25) ⁄ (318) ⁄ (352) (432) 1000 1500 2000 2500 (432) (533) 1000 2000 3000 4000 Damper size = 14 x 14 (357 x 357) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 91 (41) *Motor cover is optional.
  • Page 28 BSQ 120 - Belt Drive ⁄ (454) (406) Density 0.075 lb/ft (25) ⁄ (318) ⁄ (403) (483) 1000 1500 2000 2500 3000 (483) (533) 1000 1500 2000 2500 3000 3500 4000 4500 5000 Damper size = 16 x 16 (406 x 406) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms).
  • Page 29 BSQ 130 - Belt Drive ⁄ (454) (406) Density 0.075 lb/ft (25) ⁄ (318) ⁄ (454) (533) 1000 1500 2000 2500 3000 3500 (533) (533) 1000 2000 3000 4000 5000 Damper size = 18 x 18 (457 x 457) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 97 (44) *Motor cover is optional.
  • Page 30 BSQ 130HP - Belt Drive ⁄ (454) (406) 1100 1000 Density 0.075 lb/ft (25) ⁄ (318) ⁄ (454) (533) 1000 1500 2000 2500 (533) (533) 1000 1500 2000 2500 3000 3500 4000 Damper size = 18 x 18 (457 x 457) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms).
  • Page 31 BSQ 140 - Belt Drive ⁄ (454) (406) Density 0.075 lb/ft (25) ⁄ (318) ⁄ (505) (584) 1000 1500 2000 2500 3000 3500 4000 4500 (584) (559) 1000 2000 3000 4000 5000 6000 7000 Damper size = 20 x 20 (508 x 508) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms).
  • Page 32 BSQ 140HP - Belt Drive ⁄ (454) (406) 1200 Density 0.075 lb/ft 1000 (25) ⁄ (318) ⁄ (505) (584) 1000 1500 2000 2500 3000 3500 (584) (559) 1000 2000 3000 4000 5000 Damper size = 20 x 20 (508 x 508) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms).
  • Page 33 BSQ 160 - Belt Drive ⁄ (521) (432) Density 0.075 lb/ft (25) ⁄ (340) ⁄ (581) (660) 1000 2000 3000 4000 5000 6000 (660) (660) /hr X 1000 Damper size = 23 x 23 (584 x 584) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 208 (94) *Motor cover is optional.
  • Page 34 BSQ 160HP - Belt Drive ⁄ (521) (432) 1200 Density 0.075 lb/ft 1000 (25) ⁄ (340) ⁄ (581) (660) 1000 2000 3000 4000 5000 (660) (660) 2000 4000 6000 8000 Damper size = 23 x 23 (584 x 584) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 208 (94) *Motor cover is optional.
  • Page 35 BSQ 180 - Belt Drive ⁄ (619) (457) Density 0.075 lb/ft ⁄ (38) ⁄ (349) ⁄ (606) (711) 1000 2000 3000 4000 5000 6000 7000 (711) (711) /hr X 1000 Damper size = 24 x 24 (610 x 610) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 245 (111) *Motor cover is optional.
  • Page 36 BSQ 180HP - Belt Drive ⁄ (619) (457) Density 0.075 lb/ft ⁄ (38) ⁄ (349) ⁄ (606) (711) 1000 2000 3000 4000 5000 6000 (711) (711) /hr X 1000 Damper size = 24 x 24 (610 x 610) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 245 (111) *Motor cover is optional.
  • Page 37 BSQ 200 - Belt Drive (711) (508) Density 0.075 lb/ft ⁄ (38) (406) ⁄ (708) (813) 1000 2000 3000 4000 5000 6000 7000 8000 (813) (813) /hr X 1000 Damper size = 28 x 28 (711 x 711) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 314 (142) *Motor cover is optional.
  • Page 38 BSQ 200HP - Belt Drive (711) (508) Density 0.075 lb/ft ⁄ (38) (406) ⁄ (708) (813) 1000 2000 3000 4000 5000 6000 7000 (813) (813) /hr X 1000 Damper size = 28 x 28 (711 x 711) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 314 (142) *Motor cover is optional.
  • Page 39 BSQ 240 - Belt Drive ⁄ (835) (559) Density 0.075 lb/ft ⁄ (38) (483) ⁄ (886) (991) cfm X 1000 (991) (864) /hr X 1000 Damper size = 35 x 35 (889 x 889) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 415 (188) *Motor cover is optional.
  • Page 40 BSQ 240HP - Belt Drive ⁄ (835) (559) 1200 Density 0.075 lb/ft 1000 ⁄ (38) (483) ⁄ (886) (991) cfm X 1000 (991) (864) /hr X 1000 Damper size = 35 x 35 (889 x 889) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 415 (188) *Motor cover is optional.
  • Page 41 BSQ 300 - Belt Drive (864) (559) Density 0.075 lb/ft ⁄ (38) (457) ⁄ (1064) (1168) cfm X 1000 (1168) (965) /hr X 1000 Damper size = 42 x 42 (1067 x 1067) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 537 (244) *Motor cover is optional.
  • Page 42 BSQ 300HP - Belt Drive (864) (559) 1100 1000 Density 0.075 lb/ft ⁄ (38) (457) ⁄ (1064) (1168) (1168) cfm X 1000 (965) /hr X 1000 Damper size = 42 x 42 (1067 x 1067) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 537 (244) *Motor cover is optional.
  • Page 43 BSQ 360 - Belt Drive (864) (559) Density 0.075 lb/ft ⁄ (38) (457) ⁄ (1216) (1321) (1321) cfm X 1000 (1067) /hr X 1000 Damper size = 48 x 48 (1219 x 1219) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 686 (311) *Motor cover is optional.
  • Page 44 BSQ 360HP - Belt Drive (864) (559) 1100 1000 Density 0.075 lb/ft ⁄ (38) (457) ⁄ (1216) (1321) (1321) cfm X 1000 (1067) /hr X 1000 Damper size = 48 x 48 (1219 x 1219) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 686 (311) *Motor cover is optional.
  • Page 45 BSQ 420 - Belt Drive (864) (559) Density 0.075 lb/ft ⁄ (38) (457) ⁄ (1368) (1473) (1473) cfm X 1000 (1270) /hr X 1000 Damper size = 54 x 54 (1372 x 1372) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 789 (358) *Motor cover is optional.
  • Page 46: Specifications

    Fan shall be centrifugal direct drive type Fan shall be model SQ as manufactured by in upblast, downblast, or inline configuration with Greenheck Fan Corporation of Schofield, controllable EC Vari-Green motor. Wisconsin, USA. Remote Dial...
  • Page 47 Fan shall bear the AMCA Certified Ratings Seal for Sound and Air Performance. Fan shall bear a permanently affixed manufacturer’s nameplate containing the model number and individual serial number for future identification. Fan shall be model BSQ as manufactured by Greenheck Fan Corporation of Schofield, Wisconsin, USA.
  • Page 48: Quick Delivery

    As a result of our commitment to continuous improvement, Greenheck reserves the right to change Green Building Efforts specifications without notice. 00.F&V.1016 R8 4-2012 IP P.O. Box 410 • Schofield, WI 54476-0410 • Phone (715) 359-6171 • greenheck.com Copyright © 2012 Greenheck Fan Corp.

Table of Contents