Download Print this page
Omron B3SN-3012 Manual

Omron B3SN-3012 Manual

Tactile switch

Advertisement

Quick Links

Tactile Switch (Sealed SMD Type)
Designed as Surface-mounting Device
(SMD) Meeting High-density Mounting
Requirements
SMD Tactile Switch ideal for high-density mounting.
Compact and more than 1 mm thinner than
conventional tactile switches.
Available with ground terminals for protection
against static electricity.
Sealed construction conforming to IP64 (IEC-529)
provides high reliability in dusty or humid
environments.
Ordering Information
Model Number Legend:
B3SN-
1
2
3
4
5
1.
Height
3:
3.1 mm
2.
Ground terminal
0:
Without ground terminal
1:
With ground terminal
3.
Sealing
1:
IP64 (IEC529)
List of Models
Type
Without ground terminal
With ground terminal
Note: Switches on embossed tape must be ordered in units of 3,000 pieces.
For details on packing, refer to Switch Pacing on page 17.
Specifications
Ratings/Characteristics
Switching capacity
Contact configuration
Contact resistance
Insulation resistance
Dielectric strength
Bounce time
Vibration resistance
Shock resistance
Life expectancy
Ambient temperature
Ambient humidity
Weight
Bags
B3SN-3012
B3SN-3112
1 to 30 mA, 5 to 24 VDC (resistive load)
SPST-NO
100 mΩ max. (initial value) (rated: 1 mA, 5 VDC)
100 MΩ min. (at 250 VDC)
250 VAC, 50/60 Hz for 1 min
5 ms max.
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
2
Destruction: 1,000 m/s
{approx. 100G} max.
100,000 operations min.
Operating: –25 C to 70 C (with no icing)
Operating: 35% to 85%
Approx. 0.2 g
4.
Operating force (OF)
2:
1.57 N {160 gf}
5.
Shipment package
None: Bag
P:
Embossed tape
Embossed tape (see note)
B3SN-3012P
B3SN-3112P
B3SN
1

Advertisement

loading

Summary of Contents for Omron B3SN-3012

  • Page 1 IP64 (IEC529) List of Models Type Bags Embossed tape (see note) Without ground terminal B3SN-3012 B3SN-3012P With ground terminal B3SN-3112 B3SN-3112P Note: Switches on embossed tape must be ordered in units of 3,000 pieces. For details on packing, refer to Switch Pacing on page 17.
  • Page 2 B3SN B3SN Engineering Data Operating Force vs. Stroke (Typical) 1.96 {200} 1.47 {150} 0.98 {100} 0.49 {50} Stroke S (mm) Nomenclature Film Plunger Push button Contact dome Cover Fixed contact Terminals Base...
  • Page 3 2. No terminal numbers are indicated on the Switches. The numbers used for terminals in the following graphics are indicated in the “Bottom View” diagram below. In this diagram, the Switch is rotated so that the terminals are on the right and left-hand sides, and the OMRON logo appears the right way up. (Bottom View)
  • Page 4 B3SN B3SN Do not apply additional force to the plunger once it has stopped 2. When using ultrasonic cleaning in two- or three-tank moving. systems, do not clean for more than one minute at a time or for more than three minutes total. Do not repeatedly press the plunger off-center or from an acute angle.

This manual is also suitable for:

B3sn-3112B3sn-3012pB3sn-3112p