INSTALLATION
WARNING:
ELECTRIC
SHOCK HAZARD
All servicing requiring
access to non-insulated
electrical components
must be performed by a
factory authorized
technician.
DO NOT open any access
panel which requires the
use of tools. Failure to
follow this warning can
result in severe electrical
shock.
CAUTION:
RISK OF
DAMAGE
DO NOT connect or energize
this appliance until all
installation instructions are
read and followed. Damage
to the appliance will result if
these instructions are not
followed.
CAUTION:
ELECTRICAL
SHOCK HAZARD
The ground lug of this
appliance must be connected
to a suitable building ground.
IMPORTANT:
Contact a licensed electrician
to install and connect
electrical power to the
appliance.
IMPORTANT:
Damage due to being
connected to the wrong
voltage or phase is NOT
covered by warranty.
ELECTRICAL INSTALLATION
1. Refer to the nameplate. Verify the electrical service power.
Voltage and phase must match the nameplate specifications.
Wiring the unit to the wrong voltage can severely damage the unit
or cause noticeably decreased performance.
2. Available electrical service amperage must meet or exceed the
specifications listed on the specification sheet provided with the
unit. Connect to the terminal block in the control unit. Wiring must
be secured to the control unit with an appropriate strain relief
(provided by installer).
IMPORTANT:
*
L1 to L2 must be 208 to 240 volts AC.
*
L2 to Neutral must be 120 volts AC
L1
L2
N
3. Tank and control unit must be connected to an appropriate building
ground. Ground connection will be marked "GND" or "
NOTE: Wire gauge, insulation type and temperature rating , as
well as type, size and construction of conduit, must meet or exceed
applicable specifications of local codes and of the National
Electrical Code.
6
208V
or
240V
120V
" .