Step 4. Stopping; Storage - North Star M157310AR Owner's Manual

Hot water/steam pressure washer –
Table of Contents

Advertisement

Stop the engine using the following steps:
WARNING:
Never disconnect the high-pressure hose from the pump or spray gun while the system is
pressurized. Relieve pressure by squeezing the spray gun trigger after the engine is turned
OFF.
1. If the heater was used, turn heat switch OFF and run cold water through the coil for at least 3
minutes while spraying.
2. Turn engine OFF.
3. Turn water supply OFF.
4. Actuate spray gun trigger to relieve system pressure.
5. Remove garden hose.
6. Remove pressure hose. If chemicals were used, remove quick connect chemical injector from
the pressure hose and water outlet.
7. Remove nozzle from spray gun.
8. Turn gasoline line valve to the OFF
9. Cool engine at least five minutes before storing -- A hot engine is a fire hazard.
When you are finished using the pressure washer, you must prepare the sprayer for storage and store
it in a proper location. Note:
o If you will be storing the sprayer in freezing conditions, follow the instructions for
preparing the sprayer for storage in freezing conditions.
o If you will not be using the sprayer again for 30 days or more, follow the instructions for
preparing the engine for long-term storage.
WARNING
• Fuel and its vapors can ignite and cause a fire. Select a well-ventilated storage area
away from sources of heat, flame, or sparks.
• A hot engine can ignite flammable materials. Always let engine cool at least five
minutes before storing.