Commissioning (see "8 Commissioning" [ 4  30])
WARNING
Commissioning method MUST be in accordance with the
instructions
from
"8 Commissioning" [ 4  30].
3

About the box

3.1

Indoor unit

3.1.1
To remove the accessories from the
indoor unit
a
b
d
e
h
i
a
Shut-off valves for water circuit
b
Overpressure bypass valve
c
Mounting plate (+ screw) for demand PCB
(EKRP1AHTA) and digital I/O PCB (EKRP1HBAA)
d
General safety precautions
e
Addendum book for optional equipment
f
Indoor unit installation manual
g
Operation manual
h
WLAN cartridge
i
Sealing rings for shut-off valves (space heating water
circuit)
j
Sealing rings for field-supplied shut-off valves (domestic
hot water circuit)
k
Sealing tape for low voltage wiring intake
3.1.2

To handle the indoor unit

Use the handles at the back and at the bottom to carry the unit.
a
a
Handles at the back of the unit
b
Handles at the bottom of the unit. Carefully tilt the unit to
the back so that the handles become visible.
ETVZ16S18+23EA6V+9W
Daikin Altherma 3 H HT F
4P644730-1 – 2021.02
this
manual.
See
c
c
f
g
j
k
a
b
b
4

Unit installation

4.1

Preparing the installation site

NOTICE
This unit is designed for operation on 2 temperature zones:
▪ underfloor heating in the main zone, this is the zone
with the lowest water temperature,
▪ radiators in the additional zone, this is the zone with
the highest water temperature.
4.1.1
Installation site requirements of the
indoor unit
▪ The indoor unit is designed for indoor installation only and for the
following ambient temperatures:
▪ Space heating operation: 5~30°C
▪ Space cooling operation: 5~35°C
▪ Domestic hot water production: 5~35°C
INFORMATION
Cooling is only applicable in case a conversion kit
(EKHVCONV*) is installed.
▪ Mind the measurement guidelines:
Maximum height difference between indoor unit and
outdoor unit
Maximum total water piping length
(a)
Precise water piping length can be determined using the Hydronic
Piping Calculation tool. The Hydronic Piping Calculation tool is
part of the Heating Solutions Navigator which can be reached via
https://professional.standbyme.daikin.eu. Please contact your
dealer if you have no access to Heating Solutions Navigator.
▪ Mind the following spacing installation guidelines:
≥500
≥600
INFORMATION
If you have limited installation space, do the following
before installing the unit in its final position:
connect the drain hose to the
remove one or both side panels.
NOTICE
When the temperature in multiple rooms is controlled by 1
thermostat, do NOT place a thermostatic valve on the
emitter in the room where the thermostat is installed.
3 About the box
10 m
(a)
50 m
(mm)
"4.3.2  To
drain"  [ 4   7]. It requires to
Installation manual