Graco 253017 Instructions-Parts List Manual page 7

55 gallon 200 liter drum size air-powered ram
Table of Contents

Advertisement

Mounting Power-Flo, Check-Mate 200,
Fire–Ball 300 and Fire–Ball 425 pumps.
NOTE: The Pump Mounting Chart on page 3 lists the
parts necessary to mount Power-Flo, Check-Mate 200,
Fire–Ball 300 and Fire–Ball 425 pumps on this ram.
Installing other pumps on the ram may require alter-
nate parts. For information, contact your Graco distrib-
utor.
1. Position the mounting brackets (57) so that the top
of the pump will clear the support beam (3).
2. For President, Monark Check-Mate 200, and
Fire–Ball Pumps only, install the mounting plate
(A) onto the mounting brackets (57) using four
screws (B) and lockwashers (C). See Fig. 4. Note
that the plate is oriented differently for the Presi-
dent and Fire–Ball 425 than for the Monark and
Fire–Ball 300.
For President and Fire–Ball 425 Pumps
A
57
For Monark and Fire–Ball 300 Pumps
A
57
Fig. 4
B
C
35
ti4179a
B
C
35
ti4180a
Setup
3. Attach the motor to the mounting brackets (57) or
mounting plate (A) with the fasteners supplied, as
applicable.
NOTE: Before proceeding to step 4, install Adapter Kit
224267 for the Fire–Ball 300 pump. Install Adapter Kit
224266 for Fire–Ball 425, 50:1 and 75:1 Pump.
4. Slide the top seal plate (G) up over the pump
intake valve and push the seal (F) onto the pump
intake housing. Leave the bottom seal plate (G)
and gasket (H) in place. See Fig. 5.
5. Loosen the mounting bracket setscrews (35), and
carefully lower the pump until the intake valve is
below the gasket (H), then tighten the setscrews.
6. Push the seal (F) down firmly against the bottom
seal plate (G).
7. Align the holes in the top seal plate with the holes
in the ram plate (63). Secure tightly to the ram
plate with the four screws (D) and washers (C).
63
Fig. 5
F
D,C
G
G
H
306934