Graco 253017 Instructions-Parts List Manual page 6

55 gallon 200 liter drum size air-powered ram
Table of Contents

Advertisement

Mounting Check-Mate 450, 800, 1000, and
2100 Pumps
NOTE: The Pump Mounting Chart on page 3 lists the
parts necessary to mount Check-Mate 450, 800, 1000,
and 2100 Pumps on this ram. Installing other pumps
on the ram may require alternate parts. For informa-
tion, contact your Graco distributor.
NOTE: This installation requires Mounting Kit 222776
and 224829 which must be ordered separately. See
Accessories on page 29.
1. Position the mounting brackets (57) so that the top
of the pump will clear the support beam (3).
2. For President and Monark Check-Mate 450 Pumps
only, install the mounting plate (A) from kit 224829
onto the mounting brackets (57) using four screws
(B) and lockwashers (C). See Fig. 2. Note that the
plate is oriented differently for the President than
for the Monark.
For President Pumps
A
J
L
57
For Monark Pumps
B
C
A
57
Fig. 2
6
306934
B
C
35
ti4179a
*
*
35
ti4180a
Setup
3. Attach the motor to the mounting brackets (57) or
mounting plate (A) with the fasteners supplied (*),
as applicable. See Fig. 2.
4. Place the gasket (K) from Mounting Kit 222776 on
the ram plate (63). See Fig. 3. Loosen the mount-
ing bracket setscrews (35), and carefully lower the
pump onto the gasket and plate. Secure the
pump's intake flange (N) to the plate with the
screws (L) and lugs (M) included in the mounting
kit.
L
M
Fig. 3
N
K
63
02940

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents